The facet joint is a crucial anatomic region of the spine owing to its biomechanical role in facilitating articulation of the vertebrae of the spinal column. It is a diarthrodial joint with opposing articular cartilage surfaces that provide a low friction environment and a ligamentous capsule that encloses the joint space. Together with the disc, the bilateral facet joints transfer loads and guide and constrain motions in the spine due to their geometry and mechanical function. Although a great deal of research has focused on defining the biomechanics of the spine and the form and function of the disc, the facet joint has only recently become the focus of experimental, computational and clinical studies. This mechanical behavior ensures the normal health and function of the spine during physiologic loading but can also lead to its dysfunction when the tissues of the facet joint are altered either by injury, degeneration or as a result of surgical modification of the spine. The anatomical, biomechanical and physiological characteristics of the facet joints in the cervical and lumbar spines have become the focus of increased attention recently with the advent of surgical procedures of the spine, such as disc repair and replacement, which may impact facet responses. Accordingly, this review summarizes the relevant anatomy and biomechanics of the facet joint and the individual tissues that comprise it. In order to better understand the physiological implications of tissue loading in all conditions, a review of mechanotransduction pathways in the cartilage, ligament and bone is also presented ranging from the tissue-level scale to cellular modifications. With this context, experimental studies are summarized as they relate to the most common modifications that alter the biomechanics and health of the spine—injury and degeneration. In addition, many computational and finite element models have been developed that enable more-detailed and specific investigations of the facet joint and its tissues than are provided by experimental approaches and also that expand their utility for the field of biomechanics. These are also reviewed to provide a more complete summary of the current knowledge of facet joint mechanics. Overall, the goal of this review is to present a comprehensive review of the breadth and depth of knowledge regarding the mechanical and adaptive responses of the facet joint and its tissues across a variety of relevant size scales.
Although the mechanical phenomena associated with preconditioning are well-established, the underlying mechanisms responsible for this behavior are still not fully understood. Using quantitative polarized light imaging, this study assessed whether preconditioning alters the collagen fiber alignment of ligament tissue, and determined whether changes in fiber organization are associated with the reduced force and stiffness observed during loading. Collagen fiber alignment maps of facet capsular ligaments (n = 8) were generated before and after 30 cycles of cyclic tensile loading, and alignment vectors were correlated between the maps to identify altered fiber organization. The change in peak force and tangent stiffness between the 1st and 30th cycle were determined from the force-displacement response, and the principal strain field of the capsular ligament after preconditioning was calculated from the fiber alignment images. The decreases in peak ligament force and tangent stiffness between the 1st and 30th cycles of preconditioning were significantly correlated (R ≥ 0.976, p < 0.0001) with the change in correlation of fiber alignment vectors between maps. Furthermore, the decrease in ligament force was correlated with a rotation of the average fiber direction toward the direction of loading (R = −0.730; p = 0.0396). Decreases in peak force during loading and changes in fiber alignment after loading were correlated (p ≤ 0.0157) with the average principal strain of the unloaded ligament after preconditioning. Through the use of a vector correlation algorithm, this study quantifies detectable changes to the internal microstructure of soft tissue produced by preconditioning and demonstrates that the reorganization of the capsular ligament’s collagen fiber network, in addition to the viscoelasticity of its components, contribute to how the mechanical properties of the tissue change during its preconditioning.
Excessive cervical facet capsular ligament stretch has been implicated as a cause of whiplash-associated disorders following rear-end impacts, but the pathophysiological mechanisms that produce chronic pain in these cases remain unclear. Using a rat model of C6-C7 cervical facet joint capsule stretch that produces sustained mechanical hyperalgesia, the presence of neuronal hyperexcitability was characterized 7 days after joint loading. Extracellular recordings of spinal dorsal horn neuronal activity between C6 and C8 (117 neurons) were obtained from anesthetized rats, with both painful and non-painful behavioral outcomes established by the magnitude of capsule stretch. The frequency of neuronal firing during noxious pinch (p<0.0182) and von Frey filaments applications (4-26g) to the forepaw was increased (p<0.0156) in the painful group compared to the non-painful and sham groups. In addition, the incidence and frequency of spontaneous and after discharge firing were greater in the painful group (p<0.0307) relative to sham. The proportion of cells in the deep laminae that responded as wide dynamic range neurons also was increased in the painful group relative to non-painful or sham groups (p<0.0348). These findings suggest that excessive facet capsule stretch, while not producing visible tearing, can produce functional plasticity of dorsal horn neuronal activity. The increase in neuronal firing across a range of stimulus magnitudes observed at day 7 post-injury provides the first direct evidence of neuronal modulation in the spinal cord following facet joint loading, and suggests that facet-mediated chronic pain following whiplash injury is driven, at least in part, by central sensitization.