Yi Zheng

Prof. Yi Zheng

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YTYanpei Tian
Yanpei Tian
HSHong Shao
Hong Shao
XLXiaojie Liu
Xiaojie Liu
FCFangqi Chen
Fangqi Chen
YLYongsheng Li
Yongsheng Li
YZYi Zheng
Yi Zheng

28 July 2021 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
XLXiaojie Liu
Xiaojie Liu
YTYanpei Tian
Yanpei Tian
YWYanzi Wu
Yanzi Wu
ACAndrew Caratenuto
Andrew Caratenuto
FCFangqi Chen
Fangqi Chen
YZYi Zheng
Yi Zheng
A full ocean biomass-derived hydrogel photothermal evaporator, composed of chitosan hydrogel as the hydratable skeleton and cuttlefish ink as the photothermal material, achieves a rapid evaporation rate of 4.1 kg m −2 h −1 under one sun irradiation.

23 April 2021 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
XLXiaojie Liu
Xiaojie Liu
YTYanpei Tian
Yanpei Tian
FCFangqi Chen
Fangqi Chen
ACAndrew Caratenuto
Andrew Caratenuto
JDJoseph A DeGiorgis
Joseph A DeGiorgis
YZYi Zheng
Yi Zheng

1 September 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
XLXiaojie Liu
Xiaojie Liu
YTYanpei Tian
Yanpei Tian
YWYanzi Wu
Yanzi Wu
FCFangqi Chen
Fangqi Chen
YMYing Mu
Ying Mu
YZYi Zheng
Yi Zheng

3 March 2022 in Nano Energy
Verified
Journal Article
Closed access
YTYanpei Tian
Yanpei Tian
XLXiaojie Liu
Xiaojie Liu
ZWZiqi Wang
Ziqi Wang
JLJiansheng Li
Jiansheng Li
YMYing Mu
Ying Mu
YZYi Zheng
Yi Zheng

20 September 2024 in Science Advances
Verified
Journal Article
Open access
ACAndrew Caratenuto
Andrew Caratenuto
YZYi Zheng
Yi Zheng
Comparative evaporation rate testing in a dark environment, commonly used to characterize a reduced vaporization enthalpy in interfacial solar evaporators, requires the assumption of equal energy input between cases. However, this assumption is not generally valid, leading to misleading characterization results. Interfacial evaporators yield larger evaporation rates in dark conditions due to enlarged liquid-vapor surface areas, resulting in increased evaporative cooling and larger environmental temperature differentials. Theoretical and experimental evidence is provided, which shows that these temperature differences invalidate the equal energy input assumption. The results indicate that differences in evaporation rates correspond to energy input variations, without requiring enthalpy to be reduced below theoretical values. These findings offer alternative explanations for previous claims of reduced vaporization enthalpy and contradict enthalpy-related conclusions drawn from differential scanning calorimetry. We conclude that postulating a reduced vaporization enthalpy using the dark environment method is inaccurate and that re-evaluation of vaporization enthalpy reduction is required.