Yang Chen

Mr. Yang Chen

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
YCYang Chen
Yang Chen
SSShuo Shi
Shuo Shi
YLYing-Ke Liu
Ying-Ke Liu
SHShou-Lin Huang
Shou-Lin Huang
TMTing Ma
Ting Ma
Objective : Cuffless blood-pressure (BP) estimation has attracted widespread interest owing to its potential for long-term, non-invasive BP monitoring. But it is still impractical in clinical settings, mainly owing to ongoing challenges with respect to accuracy in hypertensive patients. To better estimate the BP, the current study proposes a new cuffless estimation method that includes a sympathetic tone, which has been reported with a varied pattern in hypertensive patients. Approach : First, the heart-rate variability of all subjects is investigated, and a new parameter, the heart-rate power spectrum ratio (HPSR), is proposed to indicate BP dynamics under sympathetic regulation. Then, a new BP estimation model is constructed by integrating HPSP with the pulse transit time (PTT) and photoplethysmography intensity ratio. The estimation accuracy is further evaluated by making comparisons with the standard sphygmomanometer BP on 60 subjects (29 hypertensive and 31 normotensive). Main results : A significant increase in HPSR was observed in hypertensive patients compared to normotensive subjects. Of the 60 subjects, the estimation accuracy was 0.73 ± 10.04 mmHg for systolic BP (SBP) and 0.90 ± 7.10 mmHg for diastolic BP (DBP) in hypertensive patients, which is comparable to 0.54 ± 7.52 mmHg for SBP and 0.82 ± 6.20 mmHg for DBP in normotensive subjects. Furthermore, the proposed method overperformed the traditional PTT-based algorithm by reducing the 3 mmHg error in the standard deviation in hypertensive patients. Significance : The results of the current study demonstrate that the inclusion of factors associated with autonomic activities in the BP estimation model would improve the BP estimation accuracy, especially for hypertensive subjects.

17 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YCYang Chen
Yang Chen
CHCHENGCHENG HONG
CHENGCHENG HONG
MPMichael R. Pinsky
Michael R. Pinsky
TMTing Ma
Ting Ma
GCGilles Clermont
Gilles Clermont
Background: There are currently no effective and accurate blood loss volume (BLV) estimation methods that can be implemented in operating rooms. To improve the accuracy and reliability of BLV estimation and facilitate clinical implementation, we propose a novel estimation method using continuously monitored photoplethysmography (PPG) and invasive arterial blood pressure (ABP). Methods: Forty anesthetized York Pigs (31.82 ± 3.52 kg) underwent a controlled hemorrhage at 20 mL/min until shock development was included. Machine-learning-based BLV estimation models were proposed and tested on normalized features derived by vital signs. Results: The results showed that the mean ± standard deviation (SD) for estimating BLV against the reference BLV of our proposed random-forest-derived BLV estimation models using PPG and ABP features, as well as the combination of ABP and PPG features, were 11.9 ± 156.2, 6.5 ± 161.5, and 7.0 ± 139.4 mL, respectively. Compared with traditional hematocrit computation formulas (estimation error: 102.1 ± 313.5 mL), our proposed models outperformed by nearly 200 mL in SD. Conclusion: This is the first attempt at predicting quantitative BLV from noninvasive measurements. Normalized PPG features are superior to ABP in accurately estimating early-stage BLV, and normalized invasive ABP features could enhance model performance in the event of a massive BLV.

10 June 2020 in Physiological Measurement
Verified
Journal Article
Closed access
YCYang Chen
Yang Chen
JYJoo Heung Yoon
Joo Heung Yoon
MPMichael R Pinsky
Michael R Pinsky
TMTing Ma
Ting Ma
GCGilles Clermont
Gilles Clermont
Objective : Early detection and timely management of bleeding is critical as failure to recognize physiologically significant bleeding is associated with significant morbidity and mortality. Many such instances are detected late, even in highly monitored environments, contributing to delay in recognition and intervention. We propose a non-invasive early identification model to detect bleeding events using continuously collected photoplethysmography (PPG) and electrocardiography (ECG) waveforms. Approach : Fifty-nine York pigs undergoing fixed-rate, controlled hemorrhage were involved in this study and a least absolute shrinkage and selection operator regression-based early detection model was developed and tested using PPG and ECG derived features. The output of the early detection model was a risk trajectory indicating the future probability of bleeding. Main results : Our proposed models were generally accurate in predicting bleeding with an area under the curve of 0.89 (95% CI 0.87–0.92) and achieved an average time of 16.1 mins to detect 16.8% blood loss when a false alert rate of 1% was tolerated. Models developed on non-invasive data performed with similar discrimination and lead time to hemorrhage compared to models using invasive arterial blood pressure as monitoring data. Significance : A bleed detection model using only non-invasive monitoring performs as well as those using invasive arterial pressure monitoring.

1 August 2014
Verified
Conference Paper
Closed access
HMHeather T. Ma
Heather T. Ma
RRRong Ren
Rong Ren
YCYang Chen
Yang Chen
JGJames F Griffith
James F Griffith
PLPing-Chung Leung
Ping-Chung Leung
PZPu Zhang
Pu Zhang
Bone marrow was assumed to be negligible on the aspect of bone mechanical behavior, where bone mass and bone mineral density were most studied. As a result, if the bone marrow, especially the marrow fat, plays a role in the bone mechanical properties is unknown yet. Marrow fat content was found increased in osteoporotic bone. However, the relationship between such change of bone marrow and bone strength is not clear yet. This study was proposed to investigate the effect of marrow fat on the bone biomechanical performance by computer simulations. A finite element model was established based on trabecular structure extracted from quantitative CT at L3 vertebrae. Simulations were conducted on the models with and without marrow fat under the same condition, respectively. The results showed that the cancellous bone with marrow fat had a 7.56%~18.81% higher maximum stress in trabeculae. Further, trabeculae with higher Young's modulus tend to sustain a higher maximum compressive stress when considering the marrow fat. As a conclusion, the marrow fat has effect on bone biomechanics, which cannot be ignored. Such effect in osteoporosis should be further investigated in deep.