Orthogonal greedy algorithms are popular sparse signal reconstruction algorithms. Their principle is to select atoms one by one. A series of unconstrained least-square subproblems of gradually increasing size is solved to compute the approximation coefficients, which is efficiently performed using a fast recursive update scheme. When dealing with nonnegative sparse signal reconstruction, a series of $non-negative$ least-squares subproblems have to be solved. Fast implementation becomes tricky since each subproblem does not have a closedform solution anymore. Recently, non-negative extensions of the classical orthogonal matching pursuit and orthogonal least squares algorithms were proposed, using slow (i.e., non-recursive) or recursive but inexact implementations. In this paper, we revisit these algorithms in a unified way. We define a class of non-negative orthogonal algorithms and exhibit their structural properties. We propose a fast and exact implementation based on the active-set resolution of non-negative least-squares and exploiting warm start initializations. The algorithms are assessed in terms of accuracy and computational complexity for a sparse spike deconvolution problem. We also present an application to near-infrared spectra decomposition.
9 November 2017 in IEEE Transactions on Computational Imaging
Speckle based imaging consists of forming a super- resolved reconstruction of an unknown sample from low- resolution images obtained under random inhomogeneous illu- minations (speckles). In a blind context where the illuminations are unknown, we study the intrinsic capacity of speckle-based imagers to recover spatial frequencies outside the frequency sup- port of the data, with minimal assumptions about the sample.We demonstrate that, under physically realistic conditions, the co- variance of the data has a super-resolution power corresponding to the squared magnitude of the imager point spread function. This theoretical result is important for many practical imaging systems such as acoustic and electromagnetic tomographs, flu- orescence and photoacoustic microscopes, or synthetic aperture radar imaging. A numerical validation is presented in the case of fluorescence microscopy.
27 April 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
In the context of nondestructive testing (NDT), this paper proposes an inverse problem approach for the reconstruction of high-resolution ultrasonic images from full matrix capture (FMC) datasets. We build a linear model that links the FMC data, i.e. the signals collected from all transmitter-receiver pairs of an ultrasonic array, to the discretized reflectivity map of the inspected object. In particular, this model includes the ultrasonic waveform corresponding to the transducers response. Despite the large amount of data, the inversion problem is illposed. Therefore, a regularization strategy is proposed, where the reconstructed image is defined as the minimizer of a penalized least-squares cost function. A mixed penalization function is considered, which simultaneously enhances the sparsity of the image (in NDT, the reflectivity map is mostly zero except at the flaw locations) and its spatial smoothness (flaws may have some spatial extension). The proposed method is shown to outperform two well-known imaging methods: the Total Focusing Method (TFM) and Excitelet. Numerical simulations with two close reflectors show that the proposed method improves the resolution limit defined by the Rayleigh criterion by a factor of four. Such high-resolution imaging capability is confirmed by experimental results obtained with side drilled holes in an aluminum sample.
15 November 2007 in Journal of Optimization Theory and Applications
A benefit of random illumination microscopy (RIM) is that it improves the resolution and linearity of the brightness of structured illumination microscopy using minimally controlled speckled illumination. Here, we implemented RIM in the total internal reflection fluorescence (TIRF) configuration for imaging biological processes close to the coverslip surface. Using standard TIRF objectives, we separated fluorescent lines 60 nm apart and achieved high contrast 86 nm resolution on fixed biological samples. Applied to live macrophages, TIRF-RIM provided two-color dynamic images of paxillin nanoclusters with remarkable spatial (96–120 nm) and temporal (1–8 Hz) resolutions, respectively. The simple experimental setup and imaging protocol together with the robustness of the data processing to leaks and aberrations make TIRF-RIM a method of choice for super-resolution TIRF imaging.
1 January 2021 in SIAM Journal on Matrix Analysis and Applications
Nonnegative matrix factorization (NMF) is the problem of approximating an input nonnegative matrix, $V$, as the product of two smaller nonnegative matrices, $W$ and $H$. In this paper, we introduce...