Camilla Tang

Ms. Camilla Tang

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Water Research
Verified
Journal Article
Closed access
UBUlla E. Bollmann
Ulla E. Bollmann
CTCamilla Tang
Camilla Tang
EEEva Eriksson
Eva Eriksson
KJKarin Jönsson
Karin Jönsson
Jes VollertsenJes Vollertsen
Jes Vollertsen
KBKai Bester
Kai Bester

1 September 2021 in Water Research
Verified
Journal Article
Open access
CTCamilla Tang
Camilla Tang
MRMartin Rygaard
Martin Rygaard
PRPer S. Rosshaug
Per S. Rosshaug
JKJohn B. Kristensen
John B. Kristensen
HAHans-Jørgen Albrechtsen
Hans-Jørgen Albrechtsen
Drinking water softening is often implemented to increase consumer convenience e.g. by reducing lime scaling and soap use. Softening reduces hardness, but changes also the overall mineral composition of the water, depending on the technology. A broad spectrum of effects from softening has to be considered in relation to e.g. health and corrosion when selecting softening technology and design, otherwise adverse effects may be overlooked in the attempt to increase consumer convenience. We here provided a framework for evaluating softening technologies using water quality indicators for lime scaling, soap use, corrosion, human health, taste and removal of contaminants. None of the evaluated softening technologies scored positive on all the included water quality indicators. Precipitation technologies (lime/soda-ash softening and pellet softening) reduce the predicted copper and lead release, but negatively affect stainless steel corrosion expressed by the Larson Ratio. Pellet softening does not remove magnesium, which may limit the achievable softening depth, but maintains a protective effect against cardio-vascular diseases. Strong-acid cation exchange is not expected to affect the included corrosion indicators, whereas the effects from membrane separation (nanofiltration and reverse osmosis) and weak-acid cation exchange depend on the specific source water and process design. All the evaluated technologies reduce hardness, calcium carbonate precipitation potential (CCPP) and atopic eczema, but have potential adverse effects on dental carries (expressed by DMF-S). Our framework provides a better understanding of softening and can prepare water utility planners and managers for better decisions that balance the positive and adverse effects from drinking water softening.

1 February 2019 in Science of The Total Environment
Verified
Journal Article
Closed access
CTCamilla Tang
Camilla Tang
MHMathilde Jørgensen Hedegaard
Mathilde Jørgensen Hedegaard
LLLaure Lopato
Laure Lopato
HAHans-Jørgen Albrechtsen
Hans-Jørgen Albrechtsen

28 December 2020 in Water
Verified
Journal Article
Open access
PDF file
CTCamilla Tang
Camilla Tang
BGBerit Godskesen
Berit Godskesen
HAHenrik Aktor
Henrik Aktor
MRMarlies van Rijn
Marlies van Rijn
JKJohn B. Kristensen
John B. Kristensen
MRMartin Rygaard
Martin Rygaard
The calcium carbonate (CaCO3) precipitation potential (CCPP) can predict the potential for corrosion and lime scaling in drinking water systems. CCPP can be calculated by different standards, but none of these consider all of the conditions in drinking water systems where temperatures can reach 100 °C and the water exchanges CO2 with the atmosphere. We provided and demonstrated a procedure for CCPP calculations using the open-source software PHREEQC with the phreeqc.dat database at temperatures relevant for drinking water systems (10–90 °C) and for open systems in equilibrium with atmospheric CO2. CCPP increased by 0.17–1.51 mmol/kg when the temperature was increased from 10 °C to 90 °C and increased by 0.22–2.82 mmol/kg when going from closed to open systems at 10 °C. Thus, CaCO3 precipitation may be underestimated if CCPP is only considered for the lower sample temperature and for closed systems. On the other hand, CCPP10 decreased by 0.006–0.173 mmol/kg when including the ionic species from the German DIN 38404-10 standard in addition to calcium, alkalinity and pH, indicating that all relevant ionic species should be included in CCPP calculations. CCPP values should always be reported with the calculation procedure and temperature to avoid inconsistency in literature.

13 June 2019 in Water Supply
Verified
Journal Article
Closed access
PDF file
CTCamilla Tang
Camilla Tang
CMCornelis Wilhelmus Adrianus Maria Merks
Cornelis Wilhelmus Adrianus Maria Merks
HAHans-Jørgen Albrechtsen
Hans-Jørgen Albrechtsen
Selected technologies for centralised or decentralised drinking water softening were evaluated based on technical, economic, environmental and aesthetic indicators to identify the optimal treatment technology for a given setting. To achieve this, we demonstrated that a number of important indicators beyond hardness reduction and costs have to be included. All the evaluated centralised softening technologies could reduce water hardness to the target of 1.3 mmol/L at the Dutch drinking water treatment plant Beilen. CARIX® treatment and pellet softening with Ca(OH)2 resulted in a lower CCPP90 (0.25–0.30 mmol/L) than nanofiltration (0.30–0.35 mmol/L). Decentralised reverse osmosis had a water consumption of >100%, whereas decentralised cation exchange had a water consumption of 2.5–4.5% which was comparable to centralised pellet softening (3.6%). Except for the electronic water conditioner that does not remove water hardness, the decentralised technologies were 7–10 times more expensive than the centralised technologies per m3 of softened water. The centralised softening technologies furthermore ensured supply of softened water to all customers in a water supply zone. Thus, in areas with hard water and limescale problems investment in centralised softening at the local water utility is more optimal than widespread implementation of decentralised systems.

1 March 1995 in FEMS Microbiology Ecology
Verified
Journal Article
Open access
PDF file
CTCamilla Tang
Camilla Tang
GHGorm Heron
Gorm Heron
TCThomas H. Christensen
Thomas H. Christensen
Aquifer sediment samples from two locations within the anaerobic leachate plume of a municipal landfill were compared with respect to microbiology (especially Fe(III)-reduction) and geochemistry. The samples close to the landfill were characterized by low contents of Fe(III), whereas samples from the more distant cluster were rich in Fe(III)-oxides. The active microbial population seemed to be less dense in samples more distant from the landfill (measured by ATP and phospholipid fatty acids (PLFA)), but the microbial communities were very similar in the two sample clusters according to the composition of PLFA. Very little, if any, Fe(III)-reduction was observed close to the landfill, but all the more distant samples showed evident microbially mediated Fe(III)-reduction. After amendment with both acetate and Fe(III), all the samples showed a potential for Fe(III)-reduction, and the in situ Fe(III)-reduction seemed to be limited by the lack of Fe(III)-availability. It was suggested, that Fe(III)-reducing populations might be facultative, surviving by use of other electron-acceptors than Fe(III), when Fe(III) is not available for reduction.