Lei Xing

Dr. Lei Xing

Department of Radiation Oncology, Stanford University, Stanford, CA, USA
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in IEEE Transactions on Neural Networks and Learning Systems
Verified
Journal Article
Closed access
XLXiaomeng Li
Xiaomeng Li
LYLequan Yu
Lequan Yu
HCHao Chen
Hao Chen
CFChi-Wing Fu
Chi-Wing Fu
Lei XingLei Xing
Lei Xing
PHPheng-Ann Heng
Pheng-Ann Heng
A common shortfall of supervised deep learning for medical imaging is the lack of labeled data, which is often expensive and time consuming to collect. This article presents a new semisupervised method for medical image segmentation, where the network is optimized by a weighted combination of a common supervised loss only for the labeled inputs and a regularization loss for both the labeled and unlabeled data. To utilize the unlabeled data, our method encourages consistent predictions of the network-in-training for the same input under different perturbations. With the semisupervised segmentation tasks, we introduce a transformation-consistent strategy in the self-ensembling model to enhance the regularization effect for pixel-level predictions. To further improve the regularization effects, we extend the transformation in a more generalized form including scaling and optimize the consistency loss with a teacher model, which is an averaging of the student model weights. We extensively validated the proposed semisupervised method on three typical yet challenging medical image segmentation tasks: 1) skin lesion segmentation from dermoscopy images in the International Skin Imaging Collaboration (ISIC) 2017 data set; 2) optic disk (OD) segmentation from fundus images in the Retinal Fundus Glaucoma Challenge (REFUGE) data set; and 3) liver segmentation from volumetric CT scans in the Liver Tumor Segmentation Challenge (LiTS) data set. Compared with state-of-the-art, our method shows superior performance on the challenging 2-D/3-D medical images, demonstrating the effectiveness of our semisupervised method for medical image segmentation.

4 July 2022 in Nature Biomedical Engineering
Verified
Journal Article
Open access
PDF file
AZAngela Zhang
Angela Zhang
Lei XingLei Xing
Lei Xing
JZJames Y Zou
James Y Zou
JWJoseph C. Wu
Joseph C. Wu
In the past decade, the application of machine learning (ML) to healthcare has helped drive the automation of physician tasks as well as enhancements in clinical capabilities and access to care. This progress has emphasized that, from model development to model deployment, data play central roles. In this Review, we provide a data-centric view of the innovations and challenges that are defining ML for healthcare. We discuss deep generative models and federated learning as strategies to augment datasets for improved model performance, as well as the use of the more recent transformer models for handling larger datasets and enhancing the modelling of clinical text. We also discuss data-focused problems in the deployment of ML, emphasizing the need to efficiently deliver data to ML models for timely clinical predictions and to account for natural data shifts that can deteriorate model performance.

18 October 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
HSHyunseok Seo
Hyunseok Seo
CHCharles Huang
Charles Huang
MBMaxime Bassenne
Maxime Bassenne
RXRuoxiu Xiao
Ruoxiu Xiao
Lei XingLei Xing
Lei Xing
Segmentation of livers and liver tumors is one of the most important steps in radiation therapy of hepatocellular carcinoma. The segmentation task is often done manually, making it tedious, labor intensive, and subject to intra-/inter- operator variations. While various algorithms for delineating organ-at-risks (OARs) and tumor targets have been proposed, automatic segmentation of livers and liver tumors remains intractable due to their low tissue contrast with respect to the surrounding organs and their deformable shape in CT images. The U-Net has gained increasing popularity recently for image analysis tasks and has shown promising results. Conventional U-Net architectures, however, suffer from three major drawbacks. First, skip connections allow for the duplicated transfer of low resolution information in feature maps to improve efficiency in learning, but this often leads to blurring of extracted image features. Secondly, high level features extracted by the network often do not contain enough high resolution edge information of the input, leading to greater uncertainty where high resolution edge dominantly affects the network's decisions such as liver and liver-tumor segmentation. Thirdly, it is generally difficult to optimize the number of pooling operations in order to extract high level global features, since the number of pooling operations used depends on the object size. To cope with these problems, we added a residual path with deconvolution and activation operations to the skip connection of the U-Net to avoid duplication of low resolution information of features. In the case of small object inputs, features in the skip connection are not incorporated with features in the residual path. Furthermore, the proposed architecture has additional convolution layers in the skip connection in order to extract high level global features of small object inputs as well as high level features of high resolution edge information of large object inputs. Efficacy of the modified U-Net (mU-Net) was demonstrated using the public dataset of Liver tumor segmentation (LiTS) challenge 2017. For liver-tumor segmentation, Dice similarity coefficient (DSC) of 89.72 %, volume of error (VOE) of 21.93 %, and relative volume difference (RVD) of - 0.49 % were obtained. For liver segmentation, DSC of 98.51 %, VOE of 3.07 %, and RVD of 0.26 % were calculated. For the public 3D Image Reconstruction for Comparison of Algorithm Database (3Dircadb), DSCs were 96.01 % for the liver and 68.14 % for liver-tumor segmentations, respectively. The proposed mU-Net outperformed existing state-of-art networks.

28 October 2019 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
LSLiyue Shen
Liyue Shen
WZWei Zhao
Wei Zhao
Lei XingLei Xing
Lei Xing

3 June 2022 in IEEE Transactions on Neural Networks and Learning Systems
Verified
Journal Article
Closed access
LSLiyue Shen
Liyue Shen
JPJohn Pauly
John Pauly
Lei XingLei Xing
Lei Xing
Image reconstruction is an inverse problem that solves for a computational image based on sampled sensor measurement. Sparsely sampled image reconstruction poses additional challenges due to limited measurements. In this work, we propose a methodology of implicit Neural Representation learning with Prior embedding (NeRP) to reconstruct a computational image from sparsely sampled measurements. The method differs fundamentally from previous deep learning-based image reconstruction approaches in that NeRP exploits the internal information in an image prior and the physics of the sparsely sampled measurements to produce a representation of the unknown subject. No large-scale data is required to train the NeRP except for a prior image and sparsely sampled measurements. In addition, we demonstrate that NeRP is a general methodology that generalizes to different imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). We also show that NeRP can robustly capture the subtle yet significant image changes required for assessing tumor progression.

31 August 2010 in Medical Physics
Verified
Journal Article
Closed access
KCKihwan Choi
Kihwan Choi
JWJing Wang
Jing Wang
LZLei Zhu
Lei Zhu
TSTae‐Suk Suh
Tae‐Suk Suh
SBStephen Boyd
Stephen Boyd
Lei XingLei Xing
Lei Xing