Shinhao Yang

Prof. Shinhao Yang

1. Environmental Sustainability Lab, Center for General Education, CTBC Business School, Tainan 709, Taiwan
+1
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2007 in Journal of Aerosol Medicine
Verified
Journal Article
Closed access
Shinhao YangShinhao Yang
Shinhao Yang
GLGrace W. M. Lee
Grace W. M. Lee
CCCheng-Min Chen
Cheng-Min Chen
CWChih-Cheng Wu
Chih-Cheng Wu
KYKuo-Pin Yu
Kuo-Pin Yu
This work investigated the size distribution of the droplet nuclei and coughed droplets by test subjects. The size distributions of droplet nuclei coughed by test subjects were determined with an aerodynamic particle sizer (APS) and scanning mobility particle sizer (SMPS) system (system 1). Coughed droplets were only sampled with the APS system (system 2). Two different schemes were employed in system 2. Furthermore, the size distribution of coughed droplets of different ages and gender was investigated to identify the effects of age and gender on droplet size distribution. Results indicated the total average size distribution of the droplet nuclei was 0.58–5.42 μm, and 82% of droplet nuclei centered in 0.74–2.12 μm. The entire average size distribution of the coughed droplets was 0.62–15.9 μm, and the average mode size was 8.35 μm. The size distribution of the coughed droplets was multimodal. The size distribution of coughed droplets showed three peaks at approximately 1 μm, 2 μm, and 8 μm. These analytical findings indicate that variation for average droplet size among the three age groups was insignificant (p > 0.1). Moreover, the variation in average droplet size between males and females was also insignificant (p > 0.1). Also, the variation in droplet concentration between males and females was significant (p > 0.1). Droplet nuclei concentrations from male subjects were considerably higher than that from females. Comparison of the droplet concentrations for subjects in different age groups demonstrated that subjects in the 30–50-year age group have the largest droplet concentrations.

1 January 2006 in Atmospheric Environment
Verified
Journal Article
Closed access
KYKuo-Pin Yu
Kuo-Pin Yu
GLGrace W. M. Lee
Grace W. M. Lee
WHWei-Ming Huang
Wei-Ming Huang
CWChihcheng Wu
Chihcheng Wu
Shinhao YangShinhao Yang
Shinhao Yang

1 October 2006 in Science of The Total Environment
Verified
Journal Article
Closed access
CWChih Cheng Wu
Chih Cheng Wu
GLGrace W. M. Lee
Grace W. M. Lee
Shinhao YangShinhao Yang
Shinhao Yang
KYKuo-Pin Yu
Kuo-Pin Yu
CLChia Ling Lou
Chia Ling Lou


7 May 2007 in Journal of Environmental Science and Health, Part A
Verified
Journal Article
Closed access
Shinhao YangShinhao Yang
Shinhao Yang
GLGrace W. M. Lee
Grace W. M. Lee
HHHsiao-Lin Huang
Hsiao-Lin Huang
YHYi-Chin Huang
Yi-Chin Huang
CLChin-Hsiang Luo
Chin-Hsiang Luo
KYKuo-Pin Yu
Kuo-Pin Yu
This study was undertaken to determine the effects of using an electret filter on aerosol penetration. Various factors, including particle size (0.05 to 0.5 μ m), aerosol charge state (neutral and single charge), face velocity (0.1, 0.3, 0.5 and 1.0 m/s), and relative humidity (RH 30% and RH 70%), were examined to assess their effects on aerosol collection characteristics. The results presented here demonstrate that the electric fields of the electret and discharged filter were −1.53 × 104 and −1.3 × 102 (V/m). The penetration through the electret filter with singly charged aerosol and neutral aerosol ranged from 0.4% to 13% and 14% to 29%, respectively. According to these results, the coulombic capture force was dominant for the smaller aerosol and the dielectrophoretic capture mechanism was considered important for the larger aerosol. The level of penetration through the electret filter increased with increasing face velocity and relative humidity. The temperature did not affect the penetration through the electret. Furthermore, from the regression analysis conducted during the operating conditions of this work, the aerosol charge was shown to exert the greatest influence on aerosol penetration.

1 May 2006 in Journal of Aerosol Science
Verified
Journal Article
Closed access
CWChih Cheng Wu
Chih Cheng Wu
GLGrace W. M. Lee
Grace W. M. Lee
PCPojen Cheng
Pojen Cheng
Shinhao YangShinhao Yang
Shinhao Yang
KYKuo Pin Yu
Kuo Pin Yu