Dariusz Szarek

Dr. Dariusz Szarek

Department of Neurosurgery, Marciniak’s Hospital, Fieldorfa 2, 54-049 Wrocław, Poland
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2023 in Symmetry
Verified
Journal Article
Open access
PDF file
Justyna Małgorzata FerchoJustyna Małgorzata Fercho
Justyna Małgorzata Fercho
MKMichał Krakowiak
Michał Krakowiak
RYRami Alan Yuser
Rami Alan Yuser
Tomasz SzmudaTomasz Szmuda
Tomasz Szmuda
PZPiotr Zieliński
Piotr Zieliński
Grzegorz MiekisiakGrzegorz Miekisiak
Grzegorz Miekisiak
Background: Frequent use of mobile devices has a known association with musculoskeletal neck pain. This study sought out to localize the region with greatest flexion in the cervical spine and explored the role of symmetry in maintaining the pose during texting. Methods: Three inertial measuring units (IMUs) superficially attached along the cervical spine divided the cervical spine into two measurable segments. Twenty-five subjects participated in the study and performed three tasks when using smartphones: sitting, standing, and walking. Data from each IMU were used to calculate the flexion of cervical divided into two segments: craniocervical junction (C0–C1) and subaxial (C1–C7). Results: The greatest flexion by far occurred at C0–C1. While sitting, standing, and walking, the mean flexion angles were 33.33 ± 13.56°, 27.50 ± 14.05°, and 32.03 ± 10.03° for the C0–C1 joint and −3.30 ± 10.10°, 2.50 ± 9.99°, and −1.05 ± 11.88° for the C2–C7 segment, respectively. There is a noticeable pattern of yaw movement of the head, with a slow rotation toward symmetry and a fast corrective movement toward the smartphone held in one hand. Conclusions: This study identified the region of greatest contribution toward forward flexion along the cervical parameters during various tasks involving smartphone use. With each task, the greatest contributor to head flexion was the C0–C1 joint. There is involuntary rotation of the cervical spine toward symmetry when texting.

3 August 2013 in Biotechnology and Applied Biochemistry
Verified
Journal Article
Closed access
PDF file
Dariusz SzarekDariusz Szarek
Dariusz Szarek
KMKrzysztof Marycz
Krzysztof Marycz
PBPaulina Bednarz
Paulina Bednarz
PTPaweł Tabakow
Paweł Tabakow
WJWłodzimierz Jarmundowicz
Włodzimierz Jarmundowicz
Jadwiga LaskaJadwiga Laska
Jadwiga Laska

14 December 2015 in The FASEB Journal
Verified
Journal Article
Open access
PDF file
Dariusz SzarekDariusz Szarek
Dariusz Szarek
KMKrzysztof Marycz
Krzysztof Marycz
ALAnna Lis
Anna Lis
ZZZbigniew Zawada
Zbigniew Zawada
PTPaweł Tabakow
Paweł Tabakow
WJWłodzimierz Jarmundowicz
Włodzimierz Jarmundowicz
Spinal cord injury (SCI) is a well‐known devastating lesion that sadly is very resistant to all treatment attempts. This fact has stimulated the exploration of multiple regenerative strategies that are examined at both the basic and clinical level. For laboratory research, different in vivo models are used, but each has many important limitations. The main limitation of these models is the high level of animal suffering related to the inflicted neurologic injury. It has caused a growing tendency to limit the injury, but this, in turn, produces incomplete SCI models and uncertainties in the neuroregeneration interpretation. To overcome such limitations, a new experimental SCI model is proposed. Geckos have been extensively examined as a potential animal model of SCI. Their spinal cord extends into the tail and can be transected without causing the typical neurologic consequences observed in rat models. In this study, we compared the gecko tail SCI model with the rat model of thoracic SCI. Anatomic and histologic analyses showed comparability between the gecko and rat in diameter of spinal canal and spinal cord, as well as applicability of multiple staining techniques (hematoxylin and eosin, immunostaining, and scanning and transmission electron microscopy). We tested the suitability of in vivo study with 3 prototype implants for the reconstruction of SCI: a multichannel sponge, a multilaminar tube, and a gel cylinder. These were compared with a spinal cord excision (control). A 20‐wk observation revealed no adverse effects of SCI on the animals' well‐being. The animals were easily housed and observed. Histologic analysis showed growth of nervous tissue elements on implant surface and implant cellular colonization. The study showed that the gecko SCI model can be used as a primary model for the assessment of SCI treatment methods. It provides a platform for testing multiple solutions with limited animal suffering before performing tests on mammals. Detailed results of the experimental conditions and testing techniques are provided.—Szarek, D., Marycz, K., Lis, A., Zawada, Z., Tabakow, P., Laska, J., Jarmundowicz, W. Lizard tail spinal cord: a new experimental model of spinal cord injury without limb paralysis. FASEB J. 30, 1391–1403 (2016). www.fasebj.org

30 April 2016 in Polymers
Verified
Journal Article
Open access
PDF file
KKrzysztof Marycz
Krzysztof Marycz
MMMonika Marędziak
Monika Marędziak
JGJakub Grzesiak
Jakub Grzesiak
Dariusz SzarekDariusz Szarek
Dariusz Szarek
ALAnna Lis
Anna Lis
Jadwiga LaskaJadwiga Laska
Jadwiga Laska
Polymeric biomaterials based on polyurethane and polylactide blends are promising candidates for regenerative medicine applications as biocompatible, bioresorbable carriers. In current research we showed that 80/20 polyurethane/polylactide blends (PU/PLDL) with confirmed biological properties in vitro may be further improved by the addition of ZnO nanoparticles for the delivery of bioactive zinc oxide for cells. The PU/PLDL blends were doped with different concentrations of ZnO (0.001%, 0.01%, 0.05%) and undertaken for in vitro biological evaluation using human adipose stromal stem cells (ASCs) and olfactory ensheathing cells (OECs). The addition of 0.001% of ZnO to the biomaterials positively influenced the morphology, proliferation, and phenotype of cells cultured on the scaffolds. Moreover, the analysis of oxidative stress markers revealed that 0.001% of ZnO added to the material decreased the stress level in both cell lines. In addition, the levels of neural-specific genes were upregulated in OECs when cultured on sample 0.001 ZnO, while the apoptosis-related genes were downregulated in OECs and ASCs in the same group. Therefore, we showed that PU/PLDL blends doped with 0.001% of ZnO exert beneficial influence on ASCs and OECs in vitro and they may be considered for future applications in the field of regenerative medicine.

Justyna Małgorzata FerchoJustyna Małgorzata Fercho
Justyna Małgorzata Fercho
MKMichał Krakowiak
Michał Krakowiak
RYRami Alan Yuser
Rami Alan Yuser
Tomasz SzmudaTomasz Szmuda
Tomasz Szmuda
PZPiotr Zieliński
Piotr Zieliński
Grzegorz MiekisiakGrzegorz Miekisiak
Grzegorz Miekisiak
Despite the frequent use of orthopedic braces or spine stabilizers in diseases such as kyphosis, lordosis, and scoliosis, as well as in the case of injuries and rehabilitation after surgeries, there is no clear evidence of their proper stabilization of the spine while carrying out daily activities. This study sought to assess the spine’s mobility while wearing three different orthopedic braces while performing basic tasks. Ten healthy subjects were enrolled. Three Inertial Measurement Units (IMUs) were attached superficially along the spine at approximate levels: cervical (C7), between thoracic (T8) and lumbar (L3), and sacrum. The angle between sensors was monitored to provide data on the sagittal profile. In addition, the displacement of the spine’s longitudinal axis was measured (rotation). There are three types of orthopedic braces: the semi-rigid Hohmann corset, the Jewett brace, and the Thoracolumbar Fixed Spinal Orthosis (TLSO). Four tasks were monitored: standing, sitting, walking, and picking up an item from the floor with one hand. All braces provided a similar level of stability in both the sagittal plane and rotational axis while lifting an object. On the other hand, while walking and sitting, the TLSO was the only orthosis providing a statistically significant rigidity in the sagittal plane. When performing a more voluntary task, the measured rigidity of softer braces was significantly increased when compared with more involuntary tasks. A certain degree of motion restriction with spinal orthoses may come from the feedback pressure, which stimulates paraspinal muscles to contract and thus increases the overall rigidity of the trunk.

21 September 2013
Verified
Journal Article
Closed access
ALAnna Lis
Anna Lis
Dariusz SzarekDariusz Szarek
Dariusz Szarek
JLJadwiga Laska
Jadwiga Laska