The detection of muscle contraction and the estimation of muscle force are essential tasks in robot-assisted rehabilitation systems. The most commonly used method to investigate muscle contraction is surface electromyography (EMG), which, however, shows considerable disadvantages in predicting the muscle force, since unpredictable factors may influence the detected force but not necessarily the EMG data. Electrical impedance myography (EIM) investigates the change in electrical impedance during muscle activities and is another promising technique to investigate muscle functions. This paper introduces the design, development, and evaluation of a device that performs EMG and EIM simultaneously for more robust measurement of muscle conditions subject to artifacts. The device is light, wearable, and wireless and has a modular design, in which the EMG, EIM, micro-controller, and communication modules are stacked and interconnected through connectors. As a result, the EIM module measures the bioimpedance between 20 and 200 with an error of less than 5% at 140 SPS. The settling time during the calibration phase of this module is less than 1000 ms. The EMG module captures the spectrum of the EMG signal between 20–150 Hz at 1 kSPS with an SNR of 67 dB. The micro-controller and communication module builds an ARM-Cortex M3 micro-controller which reads and transfers the captured data every 1 ms over RF (868 Mhz) with a baud rate of 500 kbps to a receptor connected to a PC. Preliminary measurements on a volunteer during leg extension, walking, and sit-to-stand showed the potential of the system to investigate muscle function by combining simultaneous EMG and EIM.
Atrial fibrillation (AF) is an arrhythmic cardiac disorder with a high and increasing prevalence in aging societies, which is associated with a risk for stroke and heart failure. However, early detection of onset AF can become cumbersome since it often manifests in an asymptomatic and paroxysmal nature, also known as silent AF. Large-scale screenings can help identifying silent AF and allow for early treatment to prevent more severe implications. In this work, we present a machine learning-based algorithm for assessing signal quality of hand-held diagnostic ECG devices to prevent misclassification due to insufficient signal quality. A large-scale community pharmacy-based screening study was conducted on 7295 older subjects to investigate the performance of a single-lead ECG device to detect silent AF. Classification (normal sinus rhythm or AF) of the ECG recordings was initially performed automatically by an internal on-chip algorithm. The signal quality of each recording was assessed by clinical experts and used as a reference for the training process. Signal processing stages were explicitly adapted to the individual electrode characteristics of the ECG device since its recordings differ from conventional ECG tracings. With respect to the clinical expert ratings, the artificial intelligence-based signal quality assessment (AISQA) index yielded strong correlation of 0.75 during validation and high correlation of 0.60 during testing. Our results suggest that large-scale screenings of older subjects would greatly benefit from an automated signal quality assessment to repeat measurements if applicable, suggest additional human overread and reduce automated misclassifications.
With higher levels of automation in vehicles, the need for robust driver monitoring systems increases, since it must be ensured that the driver can intervene at any moment. Drowsiness, stress and alcohol are still the main sources of driver distraction. However, physiological problems such as heart attacks and strokes also exhibit a significant risk for driver safety, especially with respect to the ageing population. In this paper, a portable cushion with four sensor units with multiple measurement modalities is presented. Capacitive electrocardiography, reflective photophlethysmography, magnetic induction measurement and seismocardiography are performed with the embedded sensors. The device can monitor the heart and respiratory rates of a vehicle driver. The promising results of the first proof-of-concept study with twenty participants in a driving simulator not only demonstrate the accuracy of the heart (above 70% of medical-grade heart rate estimations according to IEC 60601-2-27) and respiratory rate measurements (around 30% with errors below 2 BPM), but also that the cushion might be useful to monitor morphological changes in the capacitive electrocardiogram in some cases. The measurements can potentially be used to detect drowsiness and stress and thus the fitness of the driver, since heart rate variability and breathing rate variability can be captured. They are also useful for the early prediction of cardiovascular diseases, one of the main reasons for premature death. The data are publicly available in the UnoVis dataset.
4 May 2020 in IEEE Journal of Biomedical and Health Informatics
Stride time variability is an important indicator for the assessment of gait stability. An accurate extraction of the stride intervals is essential for determining stride time variability. Peak detection is a commonly used method for gait segmentation and stride time estimation. Standard peak detection algorithms often fail due to additional movement components and measurement noise. A novel algorithm for robust peak detection in inertial sensor signals was proposed in a previous contribution. In this work, we present a novel approach for estimation of stride time variability based on the formerly proposed peak detection algorithm applied to an unobtrusive sensor setup for motion monitoring. The unobtrusive sensor setup includes a wrist sensor, a pocket or belt sensor, and a necklace sensor, all equipped with both accelerometer and gyroscope. The goal of this work is to implement a generalized approach for accurate and robust stride interval determining algorithm for different sensor locations. Therefore, treadmill and level ground walking experiments were conducted with ten healthy subjects at increasing walking speeds and an age-simulating suit. With the proposed algorithm, we achieved a RMSE of 0.07 s for the stride interval estimation during treadmill walking experiments. The results give promising indications that detection of variation of stride time variability is possible using the proposed unobtrusive sensor setup.
We address the estimation of biomechanical parameters with wearable measurement technologies. In particular, we focus on the estimation of sagittal plane ankle joint stiffness in dorsiflexion/plantar flexion. For this estimation, a novel nonlinear biomechanical model of the lower leg was formulated that is driven by electromyographic signals. The model incorporates a two-dimensional kinematic description in the sagittal plane for the calculation of muscle lever arms and torques. To reduce estimation errors due to model uncertainties, a filtering algorithm is necessary that employs segmental orientation sensor measurements. Because of the model’s inherent nonlinearities and nonsmooth dynamics, a square-root cubature Kalman filter was developed. The performance of the novel estimation approach was evaluated in silico and in an experimental procedure. The experimental study was conducted with body-worn sensors and a test-bench that was specifically designed to obtain reference angle and torque measurements for a single joint. Results show that the filter is able to reconstruct joint angle positions, velocities and torque, as well as, joint stiffness during experimental test bench movements.
7 December 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
The step length is an important parameter in gait analysis. Long-term monitoring applications for gait analysis are often based on inertial measurement units (IMUs) due to their low-cost and unobtrusive nature. Spatial gait parameters, such as step or stride length, are therefore not directly accessible. In this contribution, we focus on model-based algorithms for step length estimation based on a pendant-integrated IMU during slow walking speeds. We present a model-based approach to estimate the step length, which is divided into two successive steps. As the first part of our approach, we present an algorithm for estimation of the vertical displacement of the center of mass (CoM) during gait. Based on this estimate, we present a novel approach to estimate the step length, which we have deduced from a previously published, simplified gait model. The algorithm is compared to a commonly known approach for accelometry-based step length prediction and validated against reference data obtained from a force plate-integrated treadmill for gait analysis during a clinical study with ten healthy subjects. Due to the applicability to gait stability assessment in elderly or gait impaired patients, we focus on slow walking speeds (1−4 km h −1 ). The presented algorithms outperform the existing approach and the proposed model calculations provide a more accurate prediction. For the vertical displacement, we achieved a precision of 9.3% (CoV) with an RMSE of 1.5 mm in terms of the trajectory amplitude during normal gait patterns. The step length estimation yields satisfying results with a relative prediction error of lower than 10% for walking speeds of 2−4kmh −1 .