Zhen Yang

Dr. Zhen Yang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
YSYanbing Sun
Yanbing Sun
HZHaoyan Zhang
Haoyan Zhang
NYNan Yuan
Nan Yuan
YGYulin Ge
Yulin Ge
YDYing Dai
Ying Dai
LLLiang Lu
Liang Lu

7 November 2023 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
YXYubo Xing
Yubo Xing
LDLan Dong
Lan Dong
TWTong Wang
Tong Wang
JLJing Liang
Jing Liang
NMNa Ma
Na Ma
ZYZhen Yang
Zhen Yang
Given the importance of accelerator devices, major developed and emerging countries around the world have invested substantial human and material resources into the development, construction, and operation of more advanced large-scale accelerator devices. High-precision and high-efficiency alignment of the control network is crucial for the stable operation of accelerators. This study proposes a method for measuring tunnel control networks using total station angle observation. By taking advantage of the high precision of angle observation with a total station, we use the measured results of the designed and deployed control points measured by the laser tracker to simulate the total station angle observations, combined with some length scale values in the control network measured by the laser range finder. With the angle observations and several known distances, the point coordinates can be calculated by angle intersection methods. Only angle observations are used from total stations, while different length scale reference conditions are added to constrain the control network. This is done by calculating the point accuracy of the China Spallation Neutron Source circular accelerator. The overall plane point accuracy can reach 66 μm. By using this method, personnel will spend less time on the site and are at lower risk of radiation exposure, for example by automating measurements at night. This method can be used at nighttime for measurements, avoiding the need for daytime work and shielding employees from severe radiation exposure. By employing this method, efficiency can be increased twice. For on-site measurement, it enables monitoring and automated measurement during operation, as well as providing reference for the installation and measurement of tunnel control networks for large scale accelerators such as the Circular Electron Positron Collider.

1 January 2024 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
STSheng-Da Tang
Sheng-Da Tang
YCYong-Hao Chen
Yong-Hao Chen
JTJing-Yu Tang
Jing-Yu Tang
RFRui-Rui Fan
Rui-Rui Fan
QLQiang Li
Qiang Li
KZKe-Jun Zhu
Ke-Jun Zhu

20 October 2020 in Chinese Physics B
Verified
Journal Article
Closed access
PDF file
BLBingsheng Li
Bingsheng Li
ZYZhen Yang
Zhen Yang
SXShuai Xu
Shuai Xu
KWKongfang Wei
Kongfang Wei
ZWZhiguang Wang
Zhiguang Wang
QLQing Liao
Qing Liao
Ferritic-martensitic steels and ODS steels are attractive candidates for structural materials in advanced nuclear-power systems due to their good swelling resistance. Four kinds of steels, F82H, 15Cr-ODS, SIMP and T91, are investigated in this study. We take 6.4 MeV Fe3+ ions and energy-degraded 1.0 MeV He+ ions in the irradiation of these materials to 5 dpa and 60 appm He/dpa, 200 appm He/dpa and 600 appm He/dpa at 300 °C and 450 °C, respectively. The bubble formation and distribution are investigated by transmission electron microscopy (TEM). Formation and distribution of the bubbles in the four investigated steels are compared. The influence of irradiation temperature and helium injection ratio on bubble formation is discussed. It is found that there appears to be homogenously distributed bubbles at 300 °C irradiation while heterogeneously distributed bubbles at 450 °C irradiation.

6 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
ZYZhen Yang
Zhen Yang
ZZZhiping Zou
Zhiping Zou
ZZZeyang Zhang
Zeyang Zhang
YXYubo Xing
Yubo Xing
TWTao Wang
Tao Wang
Si single crystal was implanted with 230 keV He+ ions to a fluence of 5 × 1016/cm2 at 600 °C. The structural defects in Si implanted with He at 600 °C and then annealed at 1000 °C were investigated by transmission electron microscopy (TEM) and high-resolution transmission electron microscopy (HRTEM). The microstructure of an as-implanted sample is provided for comparison. After annealing, rod-like defects were diminished, while tangled dislocations and large dislocation loops appeared. Dislocation lines trapped by cavities were directly observed. The cavities remained stable except for a transition of shape, from octahedron to tetrakaidecahedron. Stacking-fault tetrahedrons were found simultaneously. Cavity growth was independent of dislocations. The evolution of observed lattice defects is discussed.

6 April 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YCYuhang Chen
Yuhang Chen
LZLiangchao Zhao
Liangchao Zhao
JLJidong Long
Jidong Long
XHXiaozhong He
Xiaozhong He
PDPan Dong
Pan Dong
ZYZhen Yang
Zhen Yang