Rui Tang

Dr. Rui Tang


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2012 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
XQXiaotun Qiu
Xiaotun Qiu
RTRui Tang
Rui Tang
RLRanran Liu
Ranran Liu
HHHai Huang
Hai Huang
SGShengmin Guo
Shengmin Guo
HYHongyu Yu
Hongyu Yu

28 August 2013 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
HHHai Huang
Hai Huang
MLMengbing Liang
Mengbing Liang
RTRui Tang
Rui Tang
JOJonathon Oiler
Jonathon Oiler
HYHongyu Yu
Hongyu Yu
This letter reports a low-frequency micro-accelerometer implementing a liquid-state sensing body, based on molecular electronic transducer (MET) in post-CMOS compatible microfabrication technology. The device employs a sub-microliter electrolyte droplet encapsulated in oil as the sensing body, and a MET electrode configuration as the sensing read-out mechanism. The promising and unique performance of the MET design allows the fabricated device to achieve 10.8 V/G(G=9.81 m/s2) sensitivity at 20 Hz with nearly flat response over the frequency range from 1 to 50 Hz, and a low noise floor of 75 μG/√(Hz) at 20 Hz.

29 May 2013 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RTRui Tang
Rui Tang
HHHai Huang
Hai Huang
YYYong Mo Yang
Yong Mo Yang
JOJonathon Oiler
Jonathon Oiler
MLMengbing Liang
Mengbing Liang
HYHongyu Yu
Hongyu Yu
A novel design and assembly technology is developed for a three-dimensional (3-D) flexible thermal flow sensor based on convective heat transfer to reduce detection error caused by position variation of a sensor inside the flow of narrow and curved geometries, such as coronary artery. The 3-D sensor has three independent sensing elements equally distributed around the catheter tube. This arrangement introduces three independent information channels, and cross-comparisons are used to provide accurate flow measurement. The resistance of the sensing elements is measured at ~ 1-1.2 kΩ with the temperature coefficient of resistance at 0.086%/°C. Using a constant-current circuit, the three sensing elements are heated to ~ 10°C above ambient temperature. Flow testing is implemented in a pipe channel at two positions: on the wall and along the center line. Experimental results from these two positions are discussed and computational fluid dynamic simulation based on Newtonian fluid properties is implemented, showing comparable results within an acceptable range of experimental to simulation errors. Therefore, we demonstrate the capability of 3-D thermal flow sensor for detecting the position of the catheter in the flow channel, thereby providing an accurate flow measurement.