Timothy J. Muldoon

Dr. Timothy J. Muldoon


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 November 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
GGGage J. Greening
Gage J. Greening
RIRaeef Istfan
Raeef Istfan
LHLaura M. Higgins
Laura M. Higgins
KBKartik Balachandran
Kartik Balachandran
DRDarren Roblyer
Darren Roblyer
TMTimothy J. Muldoon
Timothy J. Muldoon
Optical phantoms are used in the development of various imaging systems. For certain applications, the development of thin phantoms that simulate the physical size and optical properties of tissue is important. Here, we demonstrate a method for producing thin phantom layers with tunable optical properties using poly(dimethylsiloxane) (PDMS) as a substrate material. The thickness of each layer (between 115 and 880  μm) was controlled using a spin coater. The reduced scattering and absorption coefficients were controlled using titanium dioxide and alcohol–soluble nigrosin, respectively. These optical coefficients were quantified at six discrete wavelengths (591, 631, 659, 691, 731, and 851 nm) at varying concentrations of titanium dioxide and nigrosin using spatial frequency domain imaging. From the presented data, we provide lookup tables to determine the appropriate concentrations of scattering and absorbing agents to be used in the design of PDMS-based phantoms with specific optical coefficients. In addition, heterogeneous phantoms mimicking the layered features of certain tissue types may be fabricated from multiple stacked layers, each with custom optical properties. These thin, tunable PDMS optical phantoms can simulate many tissue types and have broad imaging calibration applications in endoscopy, diffuse optical spectroscopic imaging, and optical coherence tomography, etc.

21 July 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MAMona Ahmed
Mona Ahmed
TMTimothy J. Muldoon
Timothy J. Muldoon
MEMostafa Elsaadany
Mostafa Elsaadany
First-Generation College Students (FGCSs) face myriad challenges including the lack of parental guidance, economic and social burdens, isolation, decreased belongingness, and lowered self-confidence making them at an increased risk of dropping out of college compared to their Continuing College Students (CCSs) colleagues. In addition, being in a multidisciplinary Science, Technology, Engineering, and Mathematics (STEM) field such as Biomedical Engineering (BMEG) is another challenge as it requires the integration of several disciplines. This study aims to maximize FGCSs' success and retention in Biomedical Engineering. We hypothesize that STEM-tailored faculty and peer mentoring that is focused on academic and professional development will significantly increase BMEG FGCSs' academic and professional success and enhance their belongingness to the engineering community. Study participants were assigned to either group; faculty mentoring combined with academic coaching or peer mentoring combined with academic coaching. Both quantitative and qualitative data were collected using two surveys; pre-mentoring and post-mentoring. Both faculty mentoring and peer mentoring led to increasing FGCSs' confidence, belongingness, and involvement in professional opportunities. To tackle the added challenge of studying a multidisciplinary STEM field to the challenges facing FGCSs, a mentorship program that is focused on enhancing self-confidence, sense of belonging and augmenting professional development can be employed to ensure the success, integration, and retention of FGCSs in multidisciplinary STEM fields such as Biomedical Engineering.

1 June 2024 in In vitro models
Verified
Journal Article
Open access
PDF file
SBShelby N. Bess
Shelby N. Bess
GSGaven K. Smart
Gaven K. Smart
MIMatthew J. Igoe
Matthew J. Igoe
TMTimothy J. Muldoon
Timothy J. Muldoon
Purpose: In vitro assays are essential for studying cellular biology, but traditional monolayer cultures fail to replicate the complex three-dimensional (3D) interactions of cells in living organisms. 3D culture systems offer a more accurate reflection of the cellular microenvironment. However, 3D cultures require robust and unique methods of characterization. Methods: The goal of this study was to create a 3D spheroid model using cancer cells and macrophages, and to demonstrate a custom image analysis program to assess structural and metabolic changes across spheroid microregions. Results: Structural characterization shows that cells at the necrotic core show high normalized fluorescence intensities of CD206 (M2 macrophages), cellular apoptosis (cleaved caspase-3, CC3), and hypoxia (HIF-1α and HIF-2α) compared to the proliferative edge, which shows high normalized fluorescence intensities of CD80 (M1 macrophages) and cellular proliferation (Ki67). Metabolic characterization was performed using multiphoton microscopy and fluorescence lifetime imaging (FLIM). Results show that the mean NADH lifetime at the necrotic core (1.011 ± 0.086 ns) was lower than that at the proliferative edge (1.105 ± 0.077 ns). The opposite trend is shown in the A1/A2 ratio (necrotic core: 4.864 ± 0.753; proliferative edge: 4.250 ± 0.432). Conclusion: Overall, the results of this study show that 3D multicellular spheroid models can provide a reliable solution for studying tumor biology, allowing for the evaluation of discrete changes across all spheroid microregions.

13 November 2023 in Cancer & Metabolism
Verified
Journal Article
Open access
PDF file
SBShelby N. Bess
Shelby N. Bess
MIMatthew J. Igoe
Matthew J. Igoe
ADAbby C. Denison
Abby C. Denison
TMTimothy J. Muldoon
Timothy J. Muldoon
Background: Macrophages are one of the most prevalent subsets of immune cells within the tumor microenvironment and perform a range of functions depending on the cytokines and chemokines released by surrounding cells and tissues. Recent research has revealed that macrophages can exhibit a spectrum of phenotypes, making them highly plastic due to their ability to alter their physiology in response to environmental cues. Recent advances in examining heterogeneous macrophage populations include optical metabolic imaging, such as fluorescence lifetime imaging (FLIM), and multiphoton microscopy. However, the method of detection for these systems is reliant upon the coenzymes NAD(P)H and FAD, which can be affected by factors other than cytoplasmic metabolic changes. In this study, we seek to validate these optical measures of metabolism by comparing optical results to more standard methods of evaluating cellular metabolism, such as extracellular flux assays and the presence of metabolic intermediates. Methods: Here, we used autofluorescence imaging of endogenous metabolic co-factors via multiphoton microscopy and FLIM in conjunction with oxygen consumption rate and extracellular acidification rate through Seahorse extracellular flux assays to detect changes in cellular metabolism in quiescent and classically activated macrophages in response to cytokine stimulation. Results: Based on our Seahorse XFP flux analysis, M0 and M1 macrophages exhibit comparable trends in oxygen consumption rate (OCR) and extracellular acidification rate (ECAR). Autofluorescence imaging of M0 and M1 macrophages was not only able to show acute changes in the optical redox ratio from pre-differentiation (0 hours) to 72 hours post-cytokine differentiation (M0: 0.320 to 0.258 and M1: 0.316 to 0.386), mean NADH lifetime (M0: 1.272 ns to 1.379 ns and M1: 1.265 ns to 1.206 ns), and A1/A2 ratio (M0: 3.452 to ~ 4 and M1: 3.537 to 4.529) but could also detect heterogeneity within each macrophage population. Conclusions: Overall, the findings of this study suggest that autofluorescence metabolic imaging could be a reliable technique for longitudinal tracking of immune cell metabolism during activation post-cytokine stimulation.

1 March 2017 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
APAmy J. Powless
Amy J. Powless
RCRoxanna J. Conley
Roxanna J. Conley
KFKaran A. Freeman
Karan A. Freeman
TMTimothy J. Muldoon
Timothy J. Muldoon
There exists a broad range of techniques that can be used to classify and count white blood cells in a point-of-care (POC) three-part leukocyte differential test. Improvements in lenses, light sources, and cameras for image-based POC systems have renewed interest in acridine orange (AO) as a contrast agent, whereby subpopulations of leukocytes can be differentiated by colorimetric analysis of AO fluorescence emission. We evaluated the effect on test accuracy using different AO staining and postprocessing methods in the context of an image-based POC colorimetric cell classification scheme. Thirty blood specimens were measured for percent cell counts using our POC system and a conventional hematology analyzer for comparison. Controlling the AO concentration used during whole-blood staining, the incubation time with AO, and the colorimetric ratios among the three population of leukocytes yielded a percent deviation of 0.706%, −1.534%, and −0.645% for the lymphocytes, monocytes, and granulocytes, respectively. Overall, we demonstrated that a redshift in AO fluorescence was observed at elevated AO concentrations, which lead to reproducible inaccuracy of cell counts. This study demonstrates there is a need for a strict control of the AO staining and postprocessing methods to improve test accuracy in these POC systems.