Chih-Chang Chang

Dr. Chih-Chang Chang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
PDF file
CCChih-Chang Chang
Chih-Chang Chang
DCDean Chou
Dean Chou
BPBrenton Pennicooke
Brenton Pennicooke
JRJoshua Rivera
Joshua Rivera
LTLee A. Tan
Lee A. Tan
PMPraveen V. Mummaneni
Praveen V. Mummaneni
OBJECTIVE: Potential advantages of using expandable versus static cages during transforaminal lumbar interbody fusion (TLIF) are not fully established. The authors aimed to compare the long-term radiographic outcomes of expandable versus static TLIF cages.METHODS: A retrospective review of 1- and 2-level TLIFs over a 10-year period with expandable and static cages was performed at the University of California, San Francisco. Patients with posterior column osteotomy (PCO) were subdivided. Fusion assessment, cage subsidence, anterior and posterior disc height, foraminal dimensions, pelvic incidence (PI), segmental lordosis (SL), lumbar lordosis (LL), pelvic incidence–lumbar lordosis mismatch (PI-LL), pelvic tilt (PT), sacral slope (SS), and sagittal vertical axis (SVA) were assessed.RESULTS: A consecutive series of 178 patients (with a total of 210 levels) who underwent TLIF using either static (148 levels) or expandable cages (62 levels) was reviewed. The mean patient age was 60.3 ± 11.5 years and 62.8 ± 14.1 years for the static and expandable cage groups, respectively. The mean follow-up was 42.9 ± 29.4 months for the static cage group and 27.6 ± 14.1 months for the expandable cage group. Within the 1-level TLIF group, the SL and PI-LL improved with statistical significance regardless of whether PCO was performed; however, the static group with PCOs also had statistically significant improvement in LL and SVA. The expandable cage with PCO subgroup had significant improvement in SL only. All of the foraminal parameters improved with statistical significance, regardless of the type of cages used; however, the expandable cage group had greater improvement in disc height restoration. The incidence of cage subsidence was higher in the expandable group (19.7% vs 5.4%, p = 0.0017). Within the expandable group, the unilateral facetectomy-only subgroup had a 5.6 times higher subsidence rate than the PCO subgroup (26.8% vs 4.8%, p = 0.04). Four expandable cages collapsed over time.CONCLUSIONS: Expandable TLIF cages may initially restore disc height better than static cages, but they also have higher rates of subsidence. Unilateral facetectomy alone may result in more subsidence with expandable cages than using bilateral PCO, potentially because of insufficient facet release. Although expandable cages may have more power to induce lordosis and restore disc height than static cages, subsidence and endplate violation may negate any significant gains compared to static cages.

18 March 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
JWJau-Ching Wu
Jau-Ching Wu
HCHsuan-Kan Chang
Hsuan-Kan Chang
WHWen-Cheng Huang
Wen-Cheng Huang
TTTsung-Hsi Tu
Tsung-Hsi Tu
LFLI-YU FAY
LI-YU FAY
HCHenrich Cheng
Henrich Cheng
This study aimed to investigate whether cervical disc arthroplasty (CDA) would be equally effective in elderly patients as in the young. The inclusion criteria of published clinical trials for CDA-enrolled patients covered the ages from 18 to 78 years. However, there was a paucity of data addressing the differences of outcomes between older and the younger patients. A series of consecutive patients who underwent one- or two-level CDA were retrospectively reviewed. Patients at the two extreme ends of the age distribution (≥65 and ≤ 40 years) were selected for comparison. Clinical outcome parameters included visual analog scale (VAS) of neck and arm pain, neck disability index (NDI), and Japanese Orthopaedic Association (JOA) scores. Radiographic outcomes included range of motion (ROM) at the indexed level and evaluation of heterotopic ossification (HO) by computed tomography (CT). Complication profiles were also investigated. There were 24 patients in the elderly group (≥65 years old) and 47 patients in the young group (≤40 years old) with an overall mean follow-up of 28.0 ± 21.97 months. The elderly group had more two-level CDA, and thus the mean operative time was longer (239 vs. 179 min, p < 0.05) than the young group. Both groups had similarly significant improvement in clinical outcomes at the final follow-up. All the replaced disc segments remained mobile on post-operative lateral flexion and extension radiographs. However, the elderly group had a slight decrease in mean ROM (− 0.32° ± 3.93°) at the index level after CDA when compared to that of pre-operation. In contrast, the young group had an increase in mean ROM (+ 0.68° ± 3.60°). The complication profiles were not different, though a trend toward dysphagia was noted in the elderly group (p = 0.073). The incidence or severity (grading) of HO was similar between the two groups. During the follow-up of two years, CDA was equally effective for patients over 65 years old and those under 40 years in clinical improvement. Although the elderly group demonstrated a small reduction of mean ROM after CDA, in contrast to the young group which had a small increase, the segmental mobility was well preserved at every indexed level for each group.

18 July 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
LFLI-YU FAY
LI-YU FAY
CKChao-Hung Kuo
Chao-Hung Kuo
HCHsuan-Kan Chang
Hsuan-Kan Chang
MYMei-Yin Yeh
Mei-Yin Yeh
CCChih-Chang Chang
Chih-Chang Chang
MLMeng-Jen Lee
Meng-Jen Lee
Background: The ossification of the posterior longitudinal ligament (OPLL) is one of the contributing factors leading to severe cervical spondylotic myelopathy (CSM). The mechanism causing ossification is still unclear. The current study was designed to analyze the specimens of patients with or without OPLL. Methods: The study collected 51 patients with cervical spondylosis. There were six serum samples in both the non-OPLL (NOPLL) and OPLL groups. For tissue analysis, there were seven samples in the NOPLL group and five samples in the OPLL group. The specimens of serum and tissue were analyzed by using Human Cytokine Antibody Arrays to differentiate biomarkers between the OPLL and NOPLL groups, as well as between serum and OPLL tissue. Immunohistochemical staining of the ligament tissue was undertaken for both groups. Results: For OPLL vs. NOPLL, the serum leptin levels are higher in the OPLL group, corroborating others’ observations that it may serve as a disease marker. In the tissue, angiogenin (ANG), osteopontin (OPN), and osteopro-tegerin (OPG) are higher than they are in the OPLL group (p < 0.05). For serum vs. OPLL tissue, many chemotactic cytokines demonstrated elevated levels of MIP1 delta, MCP-1, and RANTES in the serum, while many cytokines promoting or regulating bone genesis were up-regulated in tissue (oncostatin M, FGF-9, LIF, osteopontin, osteoprotegerin, TGF-beta2), as well as the factor that inhibits osteoclastogenesis (IL-10), with very few cytokines responsible for osteoclastogenesis. Molecules promoting angiogenesis, including angiotensin, vEGF, and osteoprotegerin, are abundant in the OPLL tissue, which paves the way for robust bone growth.

23 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CCChih-Chang Chang
Chih-Chang Chang
CKChao-Hung Kuo
Chao-Hung Kuo
HCHsuan-Kan Chang
Hsuan-Kan Chang
TTTsung-Hsi Tu
Tsung-Hsi Tu
LFLI-YU FAY
LI-YU FAY
WHWen-Cheng Huang
Wen-Cheng Huang
Percutaneous pedicle screw instrumentation is the keystone of minimally invasive spine surgery. Percutaneous screw placement demands experience and relies greatly on intra-operative image guidance. This study aims to validate the feasibility and accuracy of augmented-reality (AR)-assisted percutaneous pedicle screw instrumentation. One cadaveric torso was prepared for this study. After a pre-operative computed tomography (CT) scan, the images were transferred to an AR station to generate a 3D hologram. The 3D hologram and navigation images were projected to a pair of goggles with a display screen. With registration, the 3D spine hologram was overlayed onto the cadaver. Bilateral instrumentation from T6 to L5 was performed by two surgeons using AR assistance. A post-operative CT scan was obtained. The Gertzbein–Robbins scale (grade 0–3) was used for accuracy assessment. A total of 24 screws were placed. The overall screw accuracy was 87.5%. There were three major medial breaches that occurred on Rt T6/7/8, which were the most distant screws from the iliac reference. The cause of the three major medial breaches appeared to be related to their distance from the iliac reference. AR-assisted percutaneous pedicle screw instrumentation could improve anatomical visualization, facilitate surgical workflow, and provide an intuitive way of performing surgery.

30 June 2024 in Neurospine
Verified
Journal Article
Open access
PDF file
YLYao-Wen Liang
Yao-Wen Liang
YFYu-Ting Fang
Yu-Ting Fang
TLTing-Chun Lin
Ting-Chun Lin
CYCheng-Ru Yang
Cheng-Ru Yang
CCChih-Chang Chang
Chih-Chang Chang
CKChao-Hung Kuo
Chao-Hung Kuo
Objective: This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.Methods: Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.Results: The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.Conclusion: Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.

1 October 2024 in Global Spine Journal
Verified
Journal Article
Open access
HCHsuan-Kan Chang
Hsuan-Kan Chang
CCChih-Chang Chang
Chih-Chang Chang
YCYuWen Cheng
YuWen Cheng
CWChing-Lan Wu
Ching-Lan Wu
TTTsung-Hsi Tu
Tsung-Hsi Tu
WHWen-Cheng Huang
Wen-Cheng Huang
Study Design: Retrospective series. Objective: Screw loosening in the surgical treatment of lumbar spine disease is a major complication of osteopenia or osteoporosis. This study investigated the risk of screw loosening following either MIS-TLIF or pedicle screw-based dynamic stabilization (DS) in patients with osteopenia or osteoporosis. Methods: We retrospectively enrolled patients receiving 1- or 2-level MIS-TLIF or DS in a single institute. All patients were diagnosed as having lumbar spondylosis without concurrent spondylolisthesis and found by dual-energy X-ray absorptiometry to have osteopenia or osteoporosis. Screw loosening was identified by X-ray and CT. Clinical outcomes were also assessed. Results: A total of 103 patients (50 MIS-TLIF and 53 DS) were confirmed to have osteopenia (−2.5<T-score < −1.0) or osteoporosis (T-score≦-2.5). The two groups, which were followed for 33.6 ± 24.7 and 52 ± 34.5 months, had similar T-scores (−1.97 ± 0.7 and −1.97 ± 0.6, respectively, P = 0.960). While both groups had significant improvements in back and leg pain assessed by VAS, ODI, and JOA scores, there was a significant difference in overall screw loosening rates between the MIS-TLIF and DS groups analyzed by percent of patients 38% and 18.9% ( P = 0.039*) and by percent of screws 16.9% and 8% ( P = 0.002*), respectively. Subgroup analysis showed a significant difference in screw loosening rate in osteopenia patients ( P = 0.039* by person; P = 0.002* by screw), but no difference in osteoporosis patients. Conclusion: The screw loosening rate was higher in the MIS-TLIF group in the entire cohort. Osteopenia patients receiving MIS-TLIF were at significantly higher risk of screw loosening, while that risk was not different for osteoporosis patients, compared to DS.