Dandan Song

Dr. Dandan Song


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2021 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
DSDandan Song
Dandan Song
SSSohaib Shujaat
Sohaib Shujaat
KVKarla de Faria Vasconcelos
Karla de Faria Vasconcelos
YHYan Huang
Yan Huang
CPConstantinus Politis
Constantinus Politis
RJReinhilde Jacobs
Reinhilde Jacobs
Background: Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification, and measurement of peri-implant bone defects in an animal model. Methods: Fifty-four mandible blocks with implants were harvested from nine male health adult beagle dogs with acquisition of IO, CBCT and micro-CT images from all samples. Peri-implant bone defects from 16 samples were diagnosed using micro-CT and classified into 3 defect categories: dehiscence (n = 5), infrabony defect (n = 3) and crater-like defect (n = 8). Following training and calibration of the observers, they asked to detect location (mesial, distal, buccal, lingual) and shape of the defect (dehiscence, horizontal defect, vertical defect, carter-like defect) utilizing both IO and CBCT images. Both observers assessed defect depth and width on IO, CBCT and micro-CT images at each side of peri-implant bone defect via CT-analyzer software. Data were analyzed using SPSS software and a p value of < 0.05 was considered as statistically significant. Results: Overall, there was a high diagnostic accuracy for detection of bone defects with CBCT images (sensitivity: 100%/100%), while IO images showed a reduction in accuracy (sensitivity: 69%/63%). Similarly, diagnostic accuracy for defect classification was significantly higher for CBCT, whereas IO images were unable to correctly identify vestibular dehiscence, with incorrect assessment of half of the infrabony defects. For accuracy of measuring defect depth and width, a higher correlation was observed between CBCT and gold standard micro-CT (r = 0.91, 95% CI 0.86–0.94), whereas a lower correlation was seen for IO images (r = 0.82, 95% CI 0.67–0.91). Conclusions: The diagnostic accuracy and reliability of CBCT was found to be superior to IO imaging for the detection, classification, and measurement of peri-implant bone defects. The application of CBCT adds substantial information related to the peri-implant bone defect diagnosis and decision-making which cannot be achieved with conventional IO imaging.

15 December 2021 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
DSDandan Song
Dandan Song
Sohaib ShujaatSohaib Shujaat
Sohaib Shujaat
CPConstantinus Politis
Constantinus Politis
KOKaan Orhan
Kaan Orhan
RJReinhilde Jacobs
Reinhilde Jacobs

4 December 2019 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
DSDandan Song
Dandan Song
YHYan Huang
Yan Huang
JDJeroen Van Dessel
Jeroen Van Dessel
SSSohaib Shujaat
Sohaib Shujaat
KOKaan Orhan
Kaan Orhan
RJReinhilde Jacobs
Reinhilde Jacobs
Background: Autologous plasma fractions, such as platelet-rich plasma (PRP) and platelet-poor plasma (PPP), contain growth factors that can enhance neural cell survival and are therefore likely to have the ability to promote nerve regeneration. The present study compared the effect of PRP and PPP application on myelinated nerve density and diameter in the peri-implant bone region. In addition, the effect of healing time on nerve regeneration was assessed. Materials and methods: Nine beagle dogs randomly received 54 dental implants in the bilateral mandible according to a split-mouth design. Each implant was randomly assigned to one of three implant protocols: delayed implant placement with delayed loading (DIP + DL) with local application of PRP, DIP + DL with local application of PPP and DIP + DL without any plasma additive. The animals were euthanized at 1, 3, and 6 months after loading (3 dogs per time point). Block biopsies were prepared for histomorphometry in the peri-implant bone within 500 μm around the implants. Results: Myelinated nerve fibers were identified in the trabecular bone and in the osteons near the implants surface. The nerve fibers in the PRP group (median ± IQR; 2.88 ± 1.55 μm) had a significantly (p < 0.05) greater diameter compared to the PPP (2.40 ± 0.91 μm) and control (2.11 ± 1.16 μm) group. The nerve diameter after 6 months healing (3.18 ± 1.58 μm) was significantly (p < 0.05) greater compared to 1 (2.08 ± 0.89 μm) and 3 (2.49 ± 1.22 μm) months. No significant difference was found for myelinated nerve density between groups and healing time. Conclusions: The present study showed that the healing time significantly influenced the diameter of the myelinated nerve fibers in peri-implant bone. PRP exerted a significant effect on the diameter of the myelinated nerve fibers as compared to PPP. Large-scale animal studies and longer follow-up periods are needed to confirm these findings and to verify whether platelet plasma can facilitate nerve regeneration process.

1 July 2021 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
KOKaan Orhan
Kaan Orhan
Ruben PauwelsRuben Pauwels
Ruben Pauwels
YCYi Chen
Yi Chen
DSDandan Song
Dandan Song
RJReinhilde Jacobs
Reinhilde Jacobs
Objectives: The purpose of this study was to estimate the radiation dose for a dental spectral cone-beam CT (SCBCT) unit at different scanning parameters. Methods: Radiation dose measurements were performed for a commercially available dental SCBCT. Scans were obtained at different exposure times and fields of view (FOV), both for non-spectral (25×18 cm, 14×18 cm, 14×12 cm, 9×9 cm, 6×6 cm) and spectral modes (14×18 cm, 14×12 cm, 9×9 cm, 6×6 cm) with the tube voltage alternating between 80 and 110 kV for spectral mode, and fixed at 110 kV for non-spectral mode. An ion chamber was used for air kerma and dose area product (DAP) measurements. The effective dose was estimated based on the mAs using previously published logarithmic curves for CBCT units with a similar X-ray spectrum. Results: The adult effective dose, in non-spectral mode, was 44-269 µSv for small FOVs, 131-336 µSv for the medium FOV, and 163-476 µSv for the large FOV. In spectral mode, the estimated adult effective doses were 96-206 µSv for small, 299 µSv for medium and 372 µSv for large FOV protocols. Paediatric effective doses were estimated to be 75% higher than corresponding adult doses. Conclusion: SCBCT showed comparable doses with other CBCT devices, but DAP values were generally above currently published DRLs. Spectral imaging might allow for artefact reduction at comparable dose levels, which should be assessed in further image quality studies at both a technical and diagnostic levels.

18 February 2021 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
DSDandan Song
Dandan Song
SSSohaib Shujaat
Sohaib Shujaat
YHYan Huang
Yan Huang
JDJeroen Van Dessel
Jeroen Van Dessel
CPConstantinus Politis
Constantinus Politis
RJReinhilde Jacobs
Reinhilde Jacobs
Background: Bone-to-implant contact ratio (BIC%) plays a critical role in secondary stability of osseointegrated dental implants. The aim of this study was to identify the correlation of 2D/3D micro-CT images with histology as a gold standard for evaluating BIC% and to investigate the influence of the platelet-rich plasma (PRP) and platelet-poor plasma (PPP) on 3D BIC% following delayed implant placement with delayed loading (DIP+DL). Methods: Nine beagle dogs were recruited. Following bilateral extraction of mandibular 3rd premolar, 4th premolar, and 1st molar, 54 screw-type titanium implants were inserted and randomly divided into one control and two test groups based on a split-mouth design. The control group involved DIP+DL (n = 18) and both test groups included DIP+DL with local application of PRP (n = 18) and PPP (n = 18). A BIC analysis was performed utilizing 2D histomorphometry and 2D/3D micro-CT. Following identification of correlation between histology and 2D/3D micro-CT images, a 3D micro-CT assessment of the 3D BIC% at three follow-up time-points (1, 3, and 6 months) was carried out for observing the influence of PRP and PPP on BIC. Results: The 2D micro-CT BIC% values revealed a strong positive correlation with histology (r = 0.98, p < 0.001) and a moderate correlation existed with 3D micro-CT (r = 0. 67, p = 0.005). BIC levels at 1 month and combined influence of PPP and PRP irrespective of time-points revealed significantly higher 3D BIC% compared to the control. However, a reduction in 3D BIC% was observed at the 3rd and 6th month. No significant difference was observed between both PRP and PPP. Conclusions: Both 2D and 3D micro-CT demonstrated a potential to be utilized as a complimentary method for assessing BIC compared to the histological gold standard. Overall, both PRP and PPP significantly facilitated bone healing and osseointegration with a higher 3D BIC at follow-up. However, their influence was reduced as the observation period was increased.

12 June 2023 in International Journal of Paediatric Dentistry
Verified
Journal Article
Open access
Sohaib ShujaatSohaib Shujaat
Sohaib Shujaat
AKArtúr Kesztyüs
Artúr Kesztyüs
DSDandan Song
Dandan Song
TRTobias Regnstrand
Tobias Regnstrand
DBDaniel Benchimol
Daniel Benchimol
RJReinhilde Jacobs
Reinhilde Jacobs
Background: A lack of evidence exists comprehensively assessing skeletal dimensions in a Caucasian population group at different ages.Aim: To provide age‐ and gender‐specific normative skeletal dimensional measurements of the maxillary region using cone‐beam computed tomography (CBCT) imaging.Design: Cone‐beam computed tomography images of Caucasian patients were acquired and divided into different age groups ranging from 8 to 20 years. Linear measurements were taken to evaluate seven distance‐based variables, which included anterior nasal spine‐posterior nasal spine (ANS‐PNS) distance, bilateral maxillary first molar's central fossae (CF) distance, palatal vault depth (PVD), bilateral palatal cementoenamel junction (PCEJ) distance, bilateral vestibular CEJ (VCEJ) distance, bilateral jugulare distance (Jug) and arch length (AL).Results: A total of 529 patients (243 male, 286 female) were selected. ANS‐PNS and PVD showed the highest change in dimensions from 8 to 20 years of age. On the contrary, AL had the least variability in all age groups. Male patients had larger dimensions and showed a significant change in all dimensional measurements (p < .001) than female patients.Conclusion: The maxillary linear dimensions varied across different age groups. The presented maxillary normative data could serve as a reference guide for devising patient‐specific CBCT field of views.