Jan Loskot

Dr. Jan Loskot

Department of Physics, University of Hradec Králové, 500-03 Rokitanského 62, Hradec Králové, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2023 in Polymer Testing
Verified
Journal Article
Open access
JLJan Loskot
Jan Loskot
DJDaniel Jezbera
Daniel Jezbera
RLRoman Loskot
Roman Loskot
DBDamián Bušovský
Damián Bušovský
Adrian BarylskiAdrian Barylski
Adrian Barylski
MZMaciej Zubko
Maciej Zubko

1 March 2020 in Solar Energy
Verified
Journal Article
Closed access
KDKishore Kumar Devarepally
Kishore Kumar Devarepally
JLJan Loskot
Jan Loskot
JKJan Kříž
Jan Kříž
NBNick Bennett
Nick Bennett
HUHari M. Upadhyaya
Hari M. Upadhyaya
RKRaghava Reddy Kakarla
Raghava Reddy Kakarla

18 May 2022 in Journal of Drug Delivery Science and Technology
Verified
Journal Article
Closed access
ESEva Snejdrova
Eva Snejdrova
JLJan Loskot
Jan Loskot
JMJuraj Martiska
Juraj Martiska
TSTomáš Soukup
Tomáš Soukup
LPLibor Prokes
Libor Prokes
TKTomas Kucera
Tomas Kucera

28 November 2022 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
JPJolanta Pyteraf
Jolanta Pyteraf
Witold JamrózWitold Jamróz
Witold Jamróz
MKMateusz Kurek
Mateusz Kurek
UBUrszula Bąk
Urszula Bąk
JLJan Loskot
Jan Loskot
RJRenata Jachowicz
Renata Jachowicz
Due to the possibility of designing various spatial structures, three-dimensional printing can be implemented in the production of customized medicines. Nevertheless, the use of these methods for the production of dosage forms requires further optimization, understanding, and development of printouts' quality verification mechanisms. Therefore, the goal of our work was the preparation and advanced characterization of 3D printed orodispersible tablets (ODTs) containing fluconazole, printed by the fused deposition modeling (FDM) method. We prepared and analyzed 7 printable filaments containing from 10% to 70% fluconazole, used as model API. Obtaining a FDM-printable filament with such a high API content makes our work unique. In addition, we confirmed the 12-month stability of the formulation, which, to our knowledge, is the first study of this type. Next, we printed 10 series of porous tablets containing 50 mg of API from both fresh and stored filaments containing 20 %, 40 %, or 70 % fluconazole. We confirmed the high quality and precision of the printouts using scanning electron microscopy. The detailed analysis of the tablets' disintegration process included the Pharmacopeial test, but also the surface dissolution imaging analysis (SDI) and the test simulating oral conditions performed in own-constructed apparatus. For each composition, we obtained tablets disintegrating in less than 3 min, i.e., meeting the criteria for ODTs required by the European Pharmacopeia. The filaments' storage at ambient conditions did not affect the quality of the tablets. All printed tablets released over 95% of the fluconazole within 30 min. Moreover, the printouts were stable for two weeks.

26 February 2022 in Polymers
Verified
Journal Article
Open access
PDF file
JLJan Loskot
Jan Loskot
DJDaniel Jezbera
Daniel Jezbera
ZZZuzana Olmrová Zmrhalová
Zuzana Olmrová Zmrhalová
MNMartina Nalezinková
Martina Nalezinková
DADino Alferi
Dino Alferi
ABAleš Bezrouk
Aleš Bezrouk
Biodegradable biliary stents are promising treatments for biliary benign stenoses. One of the materials considered for their production is polydioxanone (PPDX), which could exhibit a suitable degradation time for use in biodegradable stents. Proper material degradation characteristics, such as sufficient stiffness and disintegration resistance maintained for a clinically relevant period, are necessary to ensure stent safety and efficacy. The hydrolytic degradation of commercially available polydioxanone biliary stents (ELLA-CS, Hradec Králové, Czech Republic) in phosphate-buffered saline (PBS) was studied. During 9 weeks of degradation, structural, physical, and surface changes were monitored using Raman spectroscopy, differential scanning calorimetry, scanning electron microscopy, and tensile and torsion tests. It was found that the changes in mechanical properties are related to the increase in the ratio of amorphous to crystalline phase, the so-called amorphicity. Monitoring the amorphicity using Raman spectroscopy has proven to be an appropriate method to assess polydioxanone biliary stent degradation. At the 1732 cm−1 Raman peak, the normalized shoulder area is less than 9 cm−1 which indicates stent disintegration. The stent disintegration started after 9 weeks of degradation in PBS, which agrees with previous in vitro studies on polydioxanone materials as well as with in vivo studies on polydioxanone biliary stents.

21 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
JLJan Loskot
Jan Loskot
DJDaniel Jezbera
Daniel Jezbera
ABAleš Bezrouk
Aleš Bezrouk
RDRafael Doležal
Rafael Doležal
RARudolf Andrýs
Rudolf Andrýs
Alena Myslivcova FučíkováAlena Myslivcova Fučíková
Alena Myslivcova Fučíková
Polydioxanone (PPDX), as an FDA approved polymer in tissue engineering, is an important component of some promising medical devices, e.g., biodegradable stents. The hydrolytic degradation of polydioxanone stents plays a key role in the safety and efficacy of treatment. A new fast and convenient method to quantitatively evaluate the hydrolytic degradation of PPDX stent material was developed. PPDX esophageal stents were degraded in phosphate-buffered saline for 24 weeks. For the first time, the changes in Raman spectra during PPDX biodegradation have been investigated here. The level of PPDX hydrolytic degradation was determined from the Raman spectra by calculating the area under the 1732 cm−1 peak shoulder. Raman spectroscopy, unlike Fourier transform infrared (FT-IR) spectroscopy, is also sensitive enough to monitor the decrease in the dye content in the stents during the degradation. Observation by a scanning electron microscope showed gradually growing cracks, eventually leading to the stent disintegration. The material crystallinity was increasing during the first 16 weeks, suggesting preferential degradation of the amorphous phase. Our results show a new easy and reliable way to evaluate the progression of PPDX hydrolytic degradation. The proposed approach can be useful for further studies on the behavior of PPDX materials, and for clinical practice.