Assisted bilateral rehabilitation has been proven to help patients improve their paretic limb ability and promote motor recovery, especially in upper limbs, after suffering a cerebrovascular accident (ACV). Robotic-assisted bilateral rehabilitation based on sEMG-driven control has been previously addressed in other studies to improve hand mobility; however, low-cost embedded solutions for the real-time bio-cooperative control of robotic rehabilitation platforms are lacking. This paper presents the RobHand (Robot for Hand Rehabilitation) system, which is an exoskeleton that supports EMG-driven assisted bilateral by using a custom-made low-cost EMG real-time embedded solution. A threshold non-pattern recognition EMG-driven control for RobHand has been developed, and it detects hand gestures of the healthy hand and replicates the gesture on the exoskeleton placed on the paretic hand. A preliminary study with ten healthy subjects is conducted to evaluate the performance in reliability, tracking accuracy and response time of the proposed EMG-driven control strategy using the EMG real-time embedded solution, and the findings could be extrapolated to stroke patients. A systematic review has been carried out to compare the results of the study, which present a 97% of overall accuracy for the detection of hand gestures and indicate the adequate time responsiveness of the system.
Real-time hand segmentation is a key process in applications that require human–computer interaction, such as gesture recognition or augmented reality systems. However, the infinite shapes and orientations that hands can adopt, their variability in skin pigmentation and the self-occlusions that continuously appear in images make hand segmentation a truly complex problem, especially with uncontrolled lighting conditions and backgrounds. The development of robust, real-time hand segmentation algorithms is essential to achieve immersive augmented reality and mixed reality experiences by correctly interpreting collisions and occlusions. In this paper, we present a simple but powerful algorithm based on the MediaPipe Hands solution, a highly optimized neural network. The algorithm processes the landmarks provided by MediaPipe using morphological and logical operators to obtain the masks that allow dynamic updating of the skin color model. Different experiments were carried out comparing the influence of the color space on skin segmentation, with the CIELab color space chosen as the best option. An average intersection over union of 0.869 was achieved on the demanding Ego2Hands dataset running at 90 frames per second on a conventional computer without any hardware acceleration. Finally, the proposed segmentation procedure was implemented in an augmented reality application to add hand occlusion for improved user immersion. An open-source implementation of the algorithm is publicly available at https://github.com/itap-robotica-medica/lightweight-hand-segmentation.
1 September 2021 in Robotics and Autonomous Systems
The effectiveness of EMG biofeedback with neurorehabilitation robotic platforms has not been previously addressed. The present work evaluates the influence of an EMG-based visual biofeedback on the user performance when performing EMG-driven bilateral exercises with a robotic hand exoskeleton. Eighteen healthy subjects were asked to perform 1-min randomly generated sequences of hand gestures (rest, open and close) in four different conditions resulting from the combination of using or not (1) EMG-based visual biofeedback and (2) kinesthetic feedback from the exoskeleton movement. The user performance in each test was measured by computing similarity between the target gestures and the recognized user gestures using the L2 distance. Statistically significant differences in the subject performance were found in the type of provided feedback (p-value 0.0124). Pairwise comparisons showed that the L2 distance was statistically significantly lower when only EMG-based visual feedback was present (2.89 ± 0.71) than with the presence of the kinesthetic feedback alone (3.43 ± 0.75, p-value = 0.0412) or the combination of both (3.39 ± 0.70, p-value = 0.0497). Hence, EMG-based visual feedback enables subjects to increase their control over the movement of the robotic platform by assessing their muscle activation in real time. This type of feedback could benefit patients in learning more quickly how to activate robot functions, increasing their motivation towards rehabilitation.
The design of safe stimulation protocols for functional electrostimulation requires knowledge of the “maximum reversible charge injection capacity” of the implantable microelectrodes. One of the main difficulties encountered in characterizing such microelectrodes is the calculation of the access voltage Va. This paper proposes a method to calculate Va that does not require prior knowledge of the overpotential terms and of the electrolyte (or excitable tissue) resistance, which is an advantage for in vivo electrochemical characterization of microelectrodes. To validate this method, we compare the calculated results with those obtained from conventional methods for characterizing three flexible platinum microelectrodes by cyclic voltammetry and voltage transient measurements. This paper presents the experimental setup, the required instrumentation, and the signal processing.
Medical instruments detection in laparoscopic video has been carried out to increase the autonomy of surgical robots, evaluate skills or index recordings. However, it has not been extended to surgical gauzes. Gauzes can provide valuable information to numerous tasks in the operating room, but the lack of an annotated dataset has hampered its research. In this article, we present a segmentation dataset with 4003 hand-labelled frames from laparoscopic video. To prove the dataset potential, we analyzed several baselines: detection using YOLOv3, coarse segmentation, and segmentation with a U-Net. Our results show that YOLOv3 can be executed in real time but provides a modest recall. Coarse segmentation presents satisfactory results but lacks inference speed. Finally, the U-Net baseline achieves a good speed-quality compromise running above 30 FPS while obtaining an IoU of 0.85. The accuracy reached by U-Net and its execution speed demonstrate that precise and real-time gauze segmentation can be achieved, training convolutional neural networks on the proposed dataset.