Mohamed Amr

Mr. Mohamed Amr

Canadian International College (CIC), Department of Electronics and Communications Engineering
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Mohamed AmrMohamed Amr
Mohamed Amr
HEHussein m. ElAttar
Hussein m. ElAttar
MEMohamed H. Abd ElAzeem
Mohamed H. Abd ElAzeem
Hesham ElbadawyHesham Elbadawy
Hesham Elbadawy
Indoor positioning has become a very promising research topic due to the growing demand for accurate node location information for indoor environments. Nonetheless, current positioning algorithms typically present the issue of inaccurate positioning due to communication noise and interferences. In addition, most of the indoor positioning techniques require additional hardware equipment and complex algorithms to achieve high positioning accuracy. This leads to higher energy consumption and communication cost. Therefore, this paper proposes an enhanced indoor positioning technique based on a novel received signal strength indication (RSSI) distance prediction and correction model to improve the positioning accuracy of target nodes in indoor environments, with contributions including a new distance correction formula based on RSSI log-distance model, a correction factor (Beta) with a correction exponent (Sigma) for each distance between unknown node and beacon (anchor nodes) which are driven from the correction formula, and by utilizing the previous factors in the unknown node, enhanced centroid positioning algorithm is applied to calculate the final node positioning coordinates. Moreover, in this study, we used Bluetooth Low Energy (BLE) beacons to meet the principle of low energy consumption. The experimental results of the proposed enhanced centroid positioning algorithm have a significantly lower average localization error (ALE) than the currently existing algorithms. Also, the proposed technique achieves higher positioning stability than conventional methods. The proposed technique was experimentally tested for different received RSSI samples’ number to verify its feasibility in real-time. The proposed technique’s positioning accuracy is promoted by 80.97% and 67.51% at the office room and the corridor, respectively, compared with the conventional RSSI trilateration positioning technique. The proposed technique also improves localization stability by 1.64 and 2.3-fold at the office room and the corridor, respectively, compared to the traditional RSSI localization method. Finally, the proposed correction model is totally possible in real-time when the RSSI sample number is 50 or more.

19 December 2022 in International Journal of Electronics and Telecommunications
Verified
Journal Article
Open access
PDF file
AEAhmed H. Eldeeb
Ahmed H. Eldeeb
Mohamed AmrMohamed Amr
Mohamed Amr
AIAmin S. Ibrahim
Amin S. Ibrahim
HKHesham Kamel
Hesham Kamel
SFSara Fouad
Sara Fouad
The 2019 Coronavirus (COVID-19) virus has caused damage on people's respiratory systems over the world. Computed Tomography (CT) is a faster complement for RT-PCR during peak virus spread times. Nowadays, Deep Learning (DL) with CT provides more robust and reliable methods for classifying patterns in medical pictures. In this paper, we proposed a simple low training proposed customized Convolutional Neural Networks (CNN) customized model based on CNN architecture that layers which are optionals may be included such as the layer of batch normalization to reduce time taken for training and a layer with a dropout to deal with overfitting. We employed a huge dataset of chest CT slices images from diverse sources COVIDx-CT, which consists of a 16,146-image dataset with 810 patients of various nationalities. The proposed customized model's classification results compared to the VGG-16, Alex Net, and ResNet50 Deep Learning models. The proposed CNN model shows robustness by achieving an overall accuracy of 93% compared to 88%, 89%, and 95% for the VGG-16, Alex Net, and ResNet50 DL models for the classification of 3 classes. When this relates to binary classification, the classification accuracy of the proposed model and the VGG-16 models were identical (almost 100% accurate), with 0.17% of misclassification in the class of Non-Covid-19, the Alex Net model achieved almost 100% classification accuracy with 0.33% misclassification in the class of Non-Covid-19. Finally, ResNet50 achieved 95% classification accuracy with 5% misclassification in the Non-Covid-19 class.