Yongchan kim

Prof. Yongchan kim

Korea University

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2008 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
JCJongmin Choi
Jongmin Choi
YKYoon-Ho Kim
Yoon-Ho Kim
YLYongtaek Lee
Yongtaek Lee
KLKyu-Jung Lee
Kyu-Jung Lee
YKYongchan kim
Yongchan kim

12 March 2014 in International Journal of Refrigeration
Verified
Journal Article
Closed access
HJHae Won Jung
Hae Won Jung
HKHoon Kang
Hoon Kang
HCHyunjoon Chung
Hyunjoon Chung
JAJae Hwan Ahn
Jae Hwan Ahn
YKYongchan kim
Yongchan kim

1 December 2007 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
YLYongtaek Lee
Yongtaek Lee
YKYongchan kim
Yongchan kim
YJYonghee Jang
Yonghee Jang
JCJong Min Choi
Jong Min Choi

13 December 2008 in International Journal of Refrigeration
Verified
Journal Article
Closed access
RYRin Yun
Rin Yun
JHJaehyeok Heo
Jaehyeok Heo
YKYongchan kim
Yongchan kim

10 September 2012 in Energies
Verified
Journal Article
Open access
PDF file
Mooyeon LeeMooyeon Lee
Mooyeon Lee
YKYongchan kim
Yongchan kim
DLDong-Yeon Lee
Dong-Yeon Lee
The objective of this study was to provide experimental data that could be used to predict frost growth and frost performance of a round plate fin-tube heat exchanger for low temperature heat pumps used in zero emission vehicles under cold weather conditions. In this study, round plate fin-tube heat exchangers were tested with variation of the fin space, air flow rate, relative humidity, and inlet air temperature. Frost height was measured and considered with the boundary layer interruption between fins. Frost height for 8.0 mm of fin space was increased by approximately 91.9% with an increase of relative humidity from 50.0% to 80.0%. The growth rate of frost height at 1.2 m3/min was observed to be 13.0% greater than that at 0.8 m3/min. Finally, the variation of the blockage ratio with fin space would be an important reference for designing advanced heat exchangers that operate under cold weather conditions.

25 October 2018 in Open Physics
Verified
Journal Article
Open access
PDF file
SYSUNGHO YUN
SUNGHO YUN
DCDowon Cha
Dowon Cha
KSKang Sub Song
Kang Sub Song
SHSeong Ho Hong
Seong Ho Hong
SLSang Hun Lee
Sang Hun Lee
YKYongchan kim
Yongchan kim
PEMFC needs to be maintained at an appropriate temperature and humidity in a rapidly changing environment for automobile applications. In this study, a pseudo-multi-dimensional dynamic model for predicting the heat and mass transfer performance of a plate-and-frame membrane humidifier for PEMFC vehicles is developed. Based on the developed model, the variations in the temperature and relative humidity at the dry air outlet are investigated according to the air flow acceleration. Moreover, the dynamic response is analyzed as a function of the amplitude and period of the sinusoidal air flow rate at actual operating conditions. The effects of heat transfer on the dynamic response are more dominant than those of mass transfer. The settling time of the temperature and relative humidity at the dry air outlet decrease with the increase in air flow acceleration. In addition, the variations in the temperature and relative humidity at the dry air outlet increase with the increases in the amplitude and period of the sinusoidal air flow rate.