Xuemei sun

Prof. Dr. Xuemei sun


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XPXueyong Pan
Xueyong Pan
CXChuntian Xu
Chuntian Xu
XSXuemei sun
Xuemei sun
JSJianhui Shi
Jianhui Shi
ZZZhilong Zhou
Zhilong Zhou
YLYunlong Liu
Yunlong Liu
An efficient battery pack-level thermal management system was crucial to ensuring the safe driving of electric vehicles. To address the challenges posed by insufficient heat dissipation in traditional liquid cooled plate battery packs and the associated high system energy consumption. This study proposes three distinct channel liquid cooling systems for square battery modules, and compares and analyzes their heat dissipation performance to ensure battery safety during high-rate discharge. The results demonstrated that the extruded multi-channel liquid cooled plate exhibits the highest heat dissipation efficiency. Subsequently, response surface experiments were conducted to analyze the width parameters of various flow channels in the liquid cooled plate Finally, the Design of Experiment (DOE) was employed to conduct optimal Latin hypercube sampling on the flow channel depth (H), mass flow (Q), and inlet and outlet diameter (d), combined with a genetic algorithm for multi-objective analysis. The Tmax of the battery module decreased by 6.84% from 40.94°C to 38.14°C and temperature mean square deviation decreased (TSD) by 62.13% from 1.69 to 0.64. Importantly, the battery thermal management model developed in this study successfully met heat dissipation requirements without significantly increasing pump energy consumption.

10 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZhilong Zhou
Zhilong Zhou
XZXu Zhang
Xu Zhang
XSXuemei sun
Xuemei sun
FXFaqiang Xia
Faqiang Xia
JZJinhao Zeng
Jinhao Zeng
In advanced manufacturing, accurate and reliable 3D geometry measurement is vital for the quality control of large-sized components with multiple small key local features. To obtain both the geometric form and spatial position of these local features, a hybrid robot-assisted laser scanning strategy is introduced, combining a laser tracker, a fringe-projection 3D scanner, and a mobile robotic unit that integrates an industrial robot with an Automated Guided Vehicle. As for improving the overall measurement accuracy, we propose an accuracy-enhanced calibration method that incorporates both error control and compensation strategies. Firstly, an accurate extrinsic parameter calibration method is proposed, which integrates robust target sphere center estimation with distance-constrained-based optimization of local common point coordinates. Subsequently, to construct a high-accuracy, large-scale spatial measurement field, an improved global calibration method is proposed, incorporating coordinate optimization and a hierarchical strategy for error control. Finally, a robot-assisted laser scanning hybrid measurement system is developed, followed by calibration and validation experiments to verify its performance. Experiments verify its high precision over 14 m (maximum error: 0.117 mm; mean: 0.112 mm) and its strong applicability in large-scale scanning of key geometric features, providing reliable data for quality manufacturing of large-scale components.

27 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZhilong Zhou
Zhilong Zhou
JSJinyong Shangguan
Jinyong Shangguan
XSXuemei sun
Xuemei sun
YLYunlong Liu
Yunlong Liu
XZXu Zhang
Xu Zhang
HLHaoran Liu
Haoran Liu
Large-sized components with numerous small key local features are essential in advanced manufacturing. Achieving high-precision quality control necessitates accurate and highly efficient three-dimensional (3D) measurement techniques. A flexible measurement system integrating a fringe-projection-based 3D scanner with an industrial robot is developed to enable the rapid measurement of large object surfaces. To enhance overall measurement accuracy, we propose an enhanced calibration method utilizing a multidimensional ball-based calibrator to simultaneously calibrate for hand-eye transformation and robot kinematic parameters. Firstly, a preliminary hand-eye calibration method is introduced to compensate for measurement errors at observation points, leveraging geometric-constraint-based optimization and a virtual single point derived via the barycentric calculation method. Subsequently, a distance-constrained calibration method is proposed to jointly estimate the hand-eye transformation and robot kinematic parameters, wherein a distance error model is constructed to link parameter errors with the measured deviations of a virtual single point. Finally, calibration and validation experiments were carried out, and the results indicate that the maximum and average measurement errors were reduced from 1.053 mm and 0.814 mm to 0.421 mm and 0.373 mm, respectively, thereby confirming the effectiveness of the proposed method.

20 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
ZZZhilong Zhou
Zhilong Zhou
JSJinyong Shangguan
Jinyong Shangguan
XSXuemei sun
Xuemei sun
YLYunlong Liu
Yunlong Liu
XZXu Zhang
Xu Zhang
HLHaoran Liu
Haoran Liu
Large-sized components with numerous small key local features are essential in advanced manufacturing. Achieving high-precision quality control necessitates accurate and high-efficiency three-dimensional (3D) measurement techniques. A flexible measurement system integrating a fringe-projection-based 3D scanner with an industrial robot is developed to enable the rapid measurement of large object surfaces. To enhance overall measurement accuracy, we propose an online calibration method utilizing a multidimensional ball-based calibrator to simultaneously calibrate for hand-eye transformation and robot kinematic parameters. Firstly, a preliminary hand–eye calibration method is introduced to compensate for measurement errors at observation points, leveraging angular-constraint-based optimization and a virtual single point derived via the barycentric calculation method. Subsequently, a distance-constrained calibration method is proposed to jointly estimate the hand–eye transformation and robot kinematic parameters, wherein a distance error model is constructed to link parameter errors with the measured deviations of a virtual single point. Finally, calibration and validation experiments were carried out, and the results indicate that the maximum and average measurement errors were reduced from 1.041 mm and 0.809 mm to 0.428 mm and 0.394 mm, respectively, thereby confirming the effectiveness of the proposed method.

1 December 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
SLShuai Li
Shuai Li
XMXiaofei Ma
Xiaofei Ma
RWRui Wang
Rui Wang
XSXuemei sun
Xuemei sun
CSChengtong Sun
Chengtong Sun
Gas counter pressure (GCP) technology can increase the pressure of melt before flowing effectively. Therefore, it has a potential to reduce shrinkage ratio and improve dimensional accuracy of conventional injection molding part. The effect of different process parameters on the shrinkage ratio of molded parts was studied by means of S/N ratio and ANOVA. The results showed that GCP pressure was the most important factor affecting the shrinkage ratio of molded parts, followed by packing time, injection pressure, mold temperature, melt temperature and packing pressure. Meanwhile, the most optimal combination of process parameters and 1.27% shrinkage ratio of parts were obtained. Finally, the influence of different process parameters on the shrinkage ratio of molded parts was also analyzed.

24 September 2026 in Physica Scripta
Verified
Journal Article
Closed access
PMPing Ma
Ping Ma
FHFeng Han
Feng Han
XSXuemei sun
Xuemei sun
JSJianhui Shi
Jianhui Shi
ZZZhijun Zhang
Zhijun Zhang
Rarefied gas mixtures can be separated by thermally induced flows in microchannels, a technique of relevance to microelectromechanical systems (MEMSs). The paper proposes a microchannel that exploits rightward/leftward flow as its primary mechanism; every component of the channel is held at a constant temperature, so that separation is achieved without wall temperature gradients or surface-property gradients, and no special surface material or treatment is required. By connecting such units periodically, a multi-stage separator is formed. The separation of He–Xe mixtures in a single microchannel unit and in the multi-stage separator is analyzed using the direct simulation Monte Carlo (DSMC) method, focusing on the influences of the Knudsen number, temperature difference, and geometric parameters. Results show that, within a microchannel unit, the lighter gas accumulates in hot regions and the heavier gas in cold regions; the diffusive velocities of He and Xe are oppositely directed, with He diffusing considerably faster, demonstrating the separation capability of the proposed configuration. In the multi-stage separator, separation degrades when the aspect ratio, row distance, or Knudsen number deviates too far from its optimum. The separation factor reaches about 1.28 at a Knudsen number of about 0.9 in the transitional flow regime, about 1.329 at an aspect ratio a / b of about 0.375, and about 1.29 at a row distance h / b of about 0.1, while it increases monotonically with the temperature difference, up to about 1.77 at the largest temperature difference tested. These results may inform the design of thermally driven gas separators in MEMS-related applications.