Xanthan gum is commonly used in drilling fluids to provide viscosity, solid suspension, and fluid-loss control. However, it is sensitive to high temperatures and not tolerant of field contaminants. This paper presents an experimental study on the effects of an eco-friendly biopolymer (diutan gum) on xanthan gum (XC) in a water-based bentonite mud. Laboratory experiments were carried out for different compositions of the biopolymers in water-based bentonite muds formulated without salt and in water-based bentonite muds containing sodium chloride (NaCl). The rheological properties of the water-based bentonite muds formulated with XC (2 Ibm) and those of the water-based bentonite muds prepared using XC (1Ibm) and diutan gum (1Ibm) were measured using Model 1100 viscometer after aging at 25 °C, 100 °C, and 120 °C for 16 h. The API fluid loss and filter cake of the mud formulations were measured using HTHP filter press. The properties of the water-based bentonite muds containing only XC were compared with those of the water-based bentonite muds containing XC and diutan gum. Presented results show that combining diutan gum and xanthan gum in a ratio of 1:1 in a water-based bentonite mud enhances its performance with respect to fluid properties—apparent viscosity, gel strength, yield points, YP/PV ratio, LSRV,n, andK. The fluid formulations also showed favorable mud cake building characteristics. Experimental data also indicate a 16%, 19%, and 34% reduction in API fluid loss values for the water-based benitoite muds containing XC in the presence of diutan gum after aging at 25 °C, 100 °C, and 120 °C for 16 h, respectively. Experimental results also show that the water-based benitoite mud containing XC and diutan gum would cause less formation damage and was tolerant of contamination with a monovalent cation (Na+). The synergy of xanthan gum and diutan gum can, therefore, improve the performance of water-based drilling fluids.
Environmental concern for our planet has changed significantly over time due to climate change, caused by an increasing population and the subsequent demand for electricity, and thus increased power generation. Considering that natural gas is regarded as a promising fuel for such a purpose, the need to integrate carbon capture technologies in such plants is becoming a necessity, if gas power plants are to be aligned with the reduction of CO2 in the atmosphere, through understanding the capturing efficacy of different absorbents under different operating conditions. Therefore, this study provided for the first time the comparison of available absorbents in relation to amine solvents (MEA, DEA, and DEA) CO2 removal efficiency, cost, and recirculation rate to achieve Climate change action through caron capture without causing absorbent disintegration. The study analyzed Flue under different amine-based solvent solutions (monoethanolamine (MEA), diethanolamine (DEA), and methyldiethanolamine (MDEA)), in order to compare their potential for CO2 reduction under different operating conditions and costs. This was simulated using ProMax 5.0 software modeled as a simple absorber tower to absorb CO2 from flue gas. Furthermore, MEA, DEA, and MDEA adsorbents were used with a temperature of 38 °C and their concentration varied from 10 to 15%. Circulation rates of 200–300 m3/h were used for each concentration and solvent. The findings deduced that MEA is a promising solvent compared to DEA and MDEA in terms of the highest CO2 captured; however, it is limited at the top outlet for clean flue gas, which contained 3.6295% of CO2 and less than half a percent of DEA and MDEA, but this can be addressed either by increasing the concentration to 15% or increasing the MEA circulation rate to 300 m3/h.
This investigation was carried out to highlight the influence of the variation of permeability of the porous media with respect to the injection orientations during enhanced gas recovery (EGR) by CO2 injection using different core samples of different petrophysical properties. The laboratory investigation was performed using core flooding technique at 1300 psig and 50 °C. The injection rates were expressed in terms of the interstitial velocities to give an indication of its magnitude and variation based on the petrophysical properties of each core sample tested. Bandera Grey, Grey Berea, and Buff Berea sandstone core samples were used with measured permeabilities of 16.08, 217.04, and 560.63 md, respectively. The dispersion coefficient was observed to increase with a decrease in permeability, with Bandera Grey having the highest dispersion coefficient and invariably higher mixing between the injected CO2 and the nascent CH4. Furthermore, this dispersion was more pronounced in the horizontal injection orientation compared to the vertical orientation with, again, the lowest permeability having a higher dispersion coefficient in the horizontal orientation by about 50%. This study highlights the importance of the permeability variation in the design of the injection strategy of EGR and provides a revision of the CO2 plume propagation at reservoir conditions during injection.
A novel high liquid pressure fine spray swirl atomizer has been developed, which incorporates a spill-return orifice into the rear face of the swirl chamber with the aim of giving a significant reduction in flowrate while maintaining the droplet size. The initial work modified a commercial atomizer to add spill return. However, drop sizes were considered to be too large and a new design was constructed based on an earlier work on efficient high-pressure (up to 120 bar) swirl atomization. The resulting fine sprays can be used for various applications such as humidification, cleaning, coating, cooling, and decontamination. The atomizer has been characterized for different geometries, supply pressures, and spill-return orifice sizes using a Laser Particle Sizer and Phase Doppler Anemometry. For an exit orifice of 0.3mm diameter and spill orifice 0.5mm diameter, the drop size (Sauter mean diameter) is less than 20m for flowrates as low as 0.1litre/min and with a mean axial drop velocity of approximately 12m/s. An average liquid volume flux of 0.014(cm3/s)/cm2 is obtained in the spray at 150mm downstream.