Currently, the implementation of hybrid proton-exchange membrane fuel cell (PEMFC)-battery-supercapacitor systems for hybrid tramways to replace conventional internal combustion engines and reduce greenhouse gas emissions has triggered an upward trend in developing energy management strategies (EMSs) to effectively deploy this integration. For this purpose, this paper introduces a comprehensive EMS consisting of high-level and low-level controls to achieve appropriate power distribution and stabilize the operating voltage of the powertrain. In the high-level control, a fuzzy logic technique and adaptive control loop are proposed to determine the reference power for energy sources under different working conditions. Meanwhile, the low-level control aims to generate a pulse-width-modulation (PWM) signal for DC/DC converter, associated with each electric source, to regulate the device’s output performance and guarantee the DC bus voltage. Comparisons between the proposed strategy with available approaches are conducted to verify the effectiveness of the proposed EMS through MATLAB/Simulink environment. The simulation results confirm that the proposed EMS not only sufficiently ensures powers distribution even when the abrupt changes of load or high peak power, but also enhance the efficiency of the PEMFC, in which the PEMFC stack efficiency can be exhibited up to 53% with hydrogen consumption less than 21.4%. Moreover, the DC bus voltage can be regulated with a small ripple of around 1%.
This paper presents a new control strategy that combines classical control and an optimization scheme to regulate the output voltage of the bidirectional converter under the presence of matched and mismatched disturbances. In detail, a control-oriented modeling method is presented first to capture the system dynamics in a common canonical form, allowing different disturbances to be considered. To estimate and compensate for unknown disturbances, an extended state observer (ESO)-based continuous sliding mode control is then proposed, which can guarantee high tracking precision, fast disturbance rejection, and chattering reduction. Next, an extremum seeking (ES)-based adaptive scheme is introduced to ensure system robustness as well as optimal control effort under different working scenarios. Finally, comparative simulations with classical proportional-integral-derivative (PID) control and constant switching gains are conducted to verify the effectiveness of the proposed adaptive control methodology through three case studies of load resistance variations, buck/boost mode switching, and input voltage variation.
Developing an energy management strategy (EMS) is an important requirement to satisfy the load power demand for a proton-exchange membrane fuel cell (PEMFC) hybrid system under different working conditions. For this objective, this paper proposes an EMS to control the power distribution between the PEMFC, battery (BAT), and supercapacitor (SC) and regulate the DC bus voltage for matching the load power demand. In this strategy, fuzzy logic rules (FLRs) and low-pass filters (LPFs) are utilized to determine the reference currents for energy sources based on their dynamic response. In addition, current and voltage control loops are designed to provide the appropriate gains for compensators that can maintain a stable voltage on the DC bus. Finally, simulations are conducted in the MATLAB/Simulink environment to validate and compare the effectiveness of the proposed strategy with others. The simulation results present that the proposed EMS achieves the highest distributed power accuracy with an error of W, while reducing the DC bus voltage ripple by 1% under various load working conditions in comparison to the other approaches.
This paper proposes a fault estimation and fault-tolerant control strategy with two observers for a pump-controlled electro-hydraulic system (PCEHS) under the presence of internal leakage faults and an external loading force. The mathematical model of the PCEHS is dedicatedly derived in the state-space form for developing control methodology. Two different observers are developed in which an extended state observer is applied to estimate the internal leakage flow rate, and a disturbance observer is used to deal with the external loading force. Then, the proposed control is designed based on the backstepping sliding mode technique in which estimated information from the observers is taken into consideration to guarantee the working performance of the system. With the proposed methodology, the robustness and stability of the controlled system are theoretically analyzed and proven by the Lyapunov theorem. Comparative simulation results are given to demonstrate the effectiveness of the proposed methodology through different testing conditions.