Silvia Muceli

Dr. Silvia Muceli

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 February 2016 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
FNFrancesco Negro
Francesco Negro
SMSilvia Muceli
Silvia Muceli
ACAnna Margherita Castronovo
Anna Margherita Castronovo
AHAles Holobar
Ales Holobar
DFDario Farina
Dario Farina
Objective. The study of motor unit behavior has been classically performed by selective recording systems of muscle electrical activity (EMG signals) and decomposition algorithms able to discriminate between individual motor unit action potentials from multi-unit signals. In this study, we provide a general framework for the decomposition of multi-channel intramuscular and surface EMG signals and we extensively validate this approach with experimental recordings. Approach. First, we describe the conditions under which the assumptions of the convolutive blind separation model are satisfied. Second, we propose an approach of convolutive sphering of the observations followed by an iterative extraction of the sources. This approach is then validated using intramuscular signals recorded by novel multi-channel thin-film electrodes on the Abductor Digiti Minimi of the hand and Tibilias Anterior muscles, as well as on high-density surface EMG signals recorded by electrode grids on the First Dorsal Interosseous muscle. The validation was based on the comparison with the gold standard of manual decomposition (for intramuscular recordings) and on the two-source method (for comparison of intramuscular and surface EMG recordings) for the three human muscles and contraction forces of up to 90% MVC. Main results. The average number of common sources identified for the validation was 14 ± 7 (averaged across all trials and subjects and all comparisons), with a rate of agreement in their discharge timings of 92.8 ± 3.2%. The average Decomposability Index, calculated on the automatic decomposed signals, was 16.0 ± 2.2 (7.3–44.1). For comparison, the same index calculated on the manual decomposed signals was 15.0 ± 3.0 (6.3–76.6). Significance. These results show that the method provides a solid framework for the decomposition of multi-channel invasive and non-invasive EMG signals that allows the study of the behavior of a large number of concurrently active motor units.

1 December 2019 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Open access
RMRoberto Merletti
Roberto Merletti
SMSilvia Muceli
Silvia Muceli
This tutorial is aimed to non-engineers using, or planning to use, surface electromyography (sEMG) as an assessment tool in the prevention, monitoring and rehabilitation fields. Its first purpose is to address the issues related to the origin and nature of the signal and to its detection (electrode size, distance, location) by one-dimensional (bipolar and linear arrays) and two-dimensional (grids) electrode systems while avoiding advanced mathematical, physical or physiological issues. Its second purpose is to outline best practices and provide general guidelines for proper signal detection. Issues related to the electrode-skin interface, signal conditioning and interpretation will be discussed in subsequent tutorials.

13 December 2011 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
SMSilvia Muceli
Silvia Muceli
DFDario Farina
Dario Farina
This paper proposes and tests on able-bodied subjects a control strategy that can be practically applied in unilateral transradial amputees for simultaneous and proportional control of multiple degrees-of-freedom (DOFs). We used artificial neural networks to estimate kinematics of the complex wrist/hand from high-density surface electromyography (EMG) signals of the contralateral limb during mirrored bilateral movements in free space. The movements tested involved the concurrent activation of wrist flexion/extension, radial/ulnar deviation, forearm pronation/supination, and hand closing. The accuracy in estimation was in the range 79%-88% (r2 index) for the four DOFs in six able-bodied subjects. Moreover, the estimation of the pronation/supination angle (wrist rotation) was influenced by the reduction in the number of EMG channels used for the estimation to a greater extent than the other DOFs. In conclusion, the proposed method and set-up provide a viable means for proportional and simultaneous control of multiple DOFs for hand prostheses.

1 March 2016 in Physiology
Verified
Journal Article
Closed access
PDF file
DFDario Farina
Dario Farina
FNFrancesco Negro
Francesco Negro
SMSilvia Muceli
Silvia Muceli
RERoger M. Enoka
Roger M. Enoka
Movements are generated by the coordinated activation of motor units. Recent technological advances have made it possible to identify the concurrent activity of several tens of motor units, in contrast with much smaller samples available in classic studies. We discuss how these advances in technology have enabled the development of a population perspective of how the central nervous system controls motor unit activity and thereby the forces exerted by muscles.

1 March 2010 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
SMSilvia Muceli
Silvia Muceli
ABAndreas Trøllund Boye
Andreas Trøllund Boye
ADAndrea d'Avella
Andrea d'Avella
DFDario Farina
Dario Farina
Muscle synergies have been proposed as a simplifying principle of generation of movements based on a low-dimensional control by the CNS. This principle may be useful for movement restoration by, e.g., functional electrical stimulation (FES), if a limited set of synergies can describe several functional tasks. This study investigates the possibility of describing a multijoint reaching task of the upper limb by a linear combination of one set of muscle synergies common to multiple directions. Surface electromyographic (EMG) signals were recorded from 12 muscles of the dominant upper limb of eight healthy men during single-joint movements and a multijoint reaching task in 12 directions in the horizontal plane. The movement kinematics was recorded by a motion analysis system. Muscle synergies were extracted with nonnegative matrix factorization of the EMG envelopes. Synergies were computed either from the single-joint movements to describe the two degrees of freedom independently or from the multijoint movements. On average, the multijoint reaching task could be accurately described in all the directions (coefficient of determination >0.85) by a linear combination of either four synergies extracted from the individual degrees of freedom or three synergies extracted from multijoint movements in at least three reaching directions. These results indicate that a large set of multijoint movements can be generated by a synergy matrix of limited dimensionality and common to all directions if the synergies are extracted from a representative number of directions. The linear combination of synergies may thus be used in strategies for restoring functions, such as FES.

28 June 2012 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
NJNing Jiang
Ning Jiang
JVJohnny Lg Vest-Nielsen
Johnny Lg Vest-Nielsen
SMSilvia Muceli
Silvia Muceli
DFDario Farina
Dario Farina
We propose a method for estimating wrist kinematics during dynamic wrist contractions from multi-channel surface electromyography (EMG). The algorithm extracts features from the surface EMG and uses dedicated multi-layer perceptron networks to estimate individual joint angles of the 3 degrees of freedom (DoFs) of the wrist. The method was designed with the aim of proportional and simultaneous control of multiple DoFs of active prostheses by unilateral amputees. Therefore, the proposed approach was tested in both unilateral transradial amputees and in intact-limbed control subjects. It was shown that the joint angles at the 3 DoFs of amputees can be estimated from surface EMG recordings , during mirrored bi-lateral contractions that simultaneously and proportionally articulated the 3 DoFs. The estimation accuracies of amputee subjects with long stumps were 62.5% ± 8.50% across all 3 DoFs, while accuracies of the intact-limbed control subjects were 72.0% ± 8.29%. The estimation results from intact-limbed subjects were consistent with earlier studies. The results from the current study demonstrated the feasibility of the proposed myoelectric control approach to provide a more intuitive myoelectric control strategy for unilateral transradial amputees.