Jonghun Kim

Dr. Jonghun Kim

Korea Institute of Energy Research

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
SKSeo-Hoon Kim
Seo-Hoon Kim
JKJonghun Kim
Jonghun Kim
Hakgeun JeongHakgeun Jeong
Hakgeun Jeong
KSKyoo-Dong Song
Kyoo-Dong Song
This study proposes the air–surface temperature ratio (ASTR) method as an in situ measurement method to rapidly and accurately measure wall U-values in existing houses. Herein, the wall U-values were measured in situ applying the heat flow meter (HFM) method of ISO 9869-1 and the ASTR method. The results obtained using the HFM and ASTR methods were compared, and the relative error rate and accuracy of the measurements were analyzed. The aging rates of the wall U-values were compared and analyzed by comparing them with the wall U-values before and after the installation of retrofit insulation. Subsequently, the ASTR method was used to analyze the U-value measurement error rates according to the number of measurement days (one day to seven days). In addition, this method calculated the appropriate measurement period required to satisfy the measurement conditions. As a result, the mean relative measurement errors rates of the HFM and ASTR methods were ±3.21%. The short-term (one day) and long-term (seven days or longer) measurement results indicated the average error rates as approximately ±2.63%. These results were included in the tolerance range. Therefore, it was determined that the ASTR method can rapidly and accurately measure wall U-values.

30 June 2015 in Energies
Verified
Journal Article
Open access
PDF file
BAByung-Lip Ahn
Byung-Lip Ahn
JPJi-Woo Park
Ji-Woo Park
SYSeunghwan Yoo
Seunghwan Yoo
JKJonghun Kim
Jonghun Kim
SLSeung-Bok Leigh
Seung-Bok Leigh
CJCheol-Yong Jang
Cheol-Yong Jang
Light-emitting diode (LED) lighting should be considered for lighting efficiency enhancement, however, waste heat from light-emitting diode (LED) lighting increases the internal cooling load during the summer season. In order to solve this problem we propose a thermal management system for light-emitting diode (LED) lighting with a heat exchanger module integrated with the building’s heating, ventilation, and air conditioning (HVAC) system to move the lighting’s waste heat outdoors. An experiment was carried out to investigate the thermal effects in a test chamber and the heat exchange rate between the heat sink and the duct air. The heat generated by the light-emitting diode (LED) lighting was calculated as 78.1% of light-emitting diode (LED) input power and the heat exchange rate of the lighting heat exchange module was estimated to be between 86.5% and 98.1% according to the light-emitting diode (LED) input power and the flow rate of air passing the heat sink. As a result, the average light-emitting diode (LED) lighting heat contribution rate for internal heat gain was determined as 0.05; this value was used to calculate the heating and cooling energy demand of the office building through an energy simulation program. In the simulation results, the cooling energy demand was reduced by 19.2% compared with the case of conventionally installed light-emitting diode (LED) lighting.

30 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
SPSeyoung Park
Seyoung Park
SKSeo Hoon Kim
Seo Hoon Kim
Hakgeun JeongHakgeun Jeong
Hakgeun Jeong
SDSung Lok Do
Sung Lok Do
JKJonghun Kim
Jonghun Kim
The amount of heat lost through the envelope of a building is one of the most important variables that affects the energy performance evaluation of a house. In addition, it is especially important to estimate and accurately diagnose the amount of heat produced by windows. In Korea, windows’ U-values reflect a building’s initial design values and thermal characteristics that determine the thermal performance of an existing building, and is a factor that can overestimate the energy performance of a building. Therefore, there is a need for a field measurement method that can accurately measure the total U-value of windows in an existing house. This study provides a method of quantitatively measuring the total U-value of windows using the infrared (IR) method in ISO 9869-2. As a result of measuring the U-value using the infrared (IR) method, the Korean Standard (KS F 2278) for window performance test result values and the root mean square error (cvRMSE) for the U-value measurements using the IR method showed a high accuracy of about 3.29%. In addition, we confirmed that the IR method is an effective (cvRMSE about 7% improvement) method that can measure the comparison result faster than the heat flow meter (HFM) method, which is a conventional thermal performance measurement method.

28 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
SLSungjin Lee
Sungjin Lee
SCSoo Cho
Soo Cho
SKSeo-Hoon Kim
Seo-Hoon Kim
JKJonghun Kim
Jonghun Kim
SCSuyong Chae
Suyong Chae
TKTaeyoen Kim
Taeyoen Kim
Neural network models are data-driven and are effective for predicting and interpreting nonlinear or unexplainable physical phenomena. This study collected building information and heating energy consumption data from 16,158 old houses, selected key input variables that affect the heating energy consumption based on the collected datasets, and developed a deep neural network (DNN) model that showed the highest accuracy for the prediction of heating energy consumption in an old house. As a result, 11 key input variables were selected, and an optimal DNN model was developed. This optimal DNN model showed the highest prediction accuracy (R2 = 0.961) when the number of hidden layers was five and the number of neurons was 22. When the optimal DNN model was applied for the standard model of low-income detached houses, the prediction accuracy (Cv(RMSE)) of the optimal DNN model, compared to the EnergyPlus calculation result, was 8.74%, which satisfied the ASHRAE standard sufficiently.

19 July 2018 in Energies
Verified
Journal Article
Open access
PDF file
SKSeo-Hoon Kim
Seo-Hoon Kim
JLJung-Hun Lee
Jung-Hun Lee
JKJonghun Kim
Jonghun Kim
SYSeung-Hwan Yoo
Seung-Hwan Yoo
Hakgeun JeongHakgeun Jeong
Hakgeun Jeong
This paper reports on a feasibility study conducted to improve the in situ measurement accuracy of the air-surface temperature ratio (ASTR) method. The measured relative error rate was analyzed using the ISO 6946 [7.69 W/(m2·K)] and Korea Energy Saving Design Standard [9.09 W/(m2·K)] indoor total surface heat transfer coefficients. The relative error rate was analyzed according to fluctuations in outdoor temperature data. The relative error rate obtained using the ISO 6946 standard was analyzed about 6.3% and that obtained using the Korea Energy Saving Design Standard was about 9.5%. The relative error rate measured for outdoor temperature fluctuations of less than 1 K was about 4.62% and that for temperatures greater than 1 K was about 14.31%. The study results confirmed the cause of the error in the measurement of the ASTR. It was also found that the accuracy of the latter can be improved when the ISO 6946 indoor total surface heat transfer coefficient is applied and when outdoor temperature fluctuations less than 1 K are sampled and analyzed.

7 October 2015 in Energies
Verified
Journal Article
Open access
PDF file
JKJeong-Gook Kim
Jeong-Gook Kim
JLJunghun Lee
Junghun Lee
BAByung-Lip Ahn
Byung-Lip Ahn
HSHwayeon Shin
Hwayeon Shin
SYSeunghwan Yoo
Seunghwan Yoo
JKJonghun Kim
Jonghun Kim
Temporary housing must be developed to support the long-term residence needs of disaster victims. The present study assesses a temporary housing unit, the so-called Mobile Energy Shelter House (MeSH), incorporating the “Korean Dwelling Insulation Standard” in order to reduce energy usage for cooling and heating. To assess energy performance, the characteristics of the indoor thermal environment were measured during the winter and summer seasons. In summer, at maximum insolation, the outdoor temperature was 37.6 °C and the indoor temperature of the MeSH ranged from 18 to 24 °C when the cooling system was not used. Conversely, during winter, the average outdoor temperature was −11.3 °C and the indoor temperature ranged from 16.09 to 20.63 °C when a temperature-controlled floor-heating was installed. Furthermore, the Predicted Mean Vote (PMV) was adopted to determine whether the ISO 7730 comfort criterion (i.e., PMV range from −0.5 to +0.5) was achieved. Based on the calculations presented here, PMV in summer ranged from −1.21 to +1.07 and that in winter ranged from −0.08 to −0.85, suggesting that the thermal environment is not always comfortable for occupants in either summer or winter. Nevertheless, the ISO comfort criterion can be achieved through varying air velocity in summer and changing clothing characteristics in winter. A comparison between yearly energy demand of existing characteristic temporary housing (Shelter House) and the MeSH modules used in this study was performed. The simulation results show a 60% difference in energy demand between MeSH and existing temporary housing shelter houses.