Beatriz Monteiro

Dr. Beatriz Monteiro


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MEMarina C. Evangelista
Marina C. Evangelista
RWRyota Watanabe
Ryota Watanabe
VLVivian S. Y. Leung
Vivian S. Y. Leung
BMBeatriz Monteiro
Beatriz Monteiro
EOElizabeth O’tOole
Elizabeth O’tOole
PSPaulo V Steagall
Paulo V Steagall
Grimace scales have been used for pain assessment in different species. This study aimed to develop and validate the Feline Grimace Scale (FGS) to detect naturally-occurring acute pain. Thirty-five client-owned and twenty control cats were video-recorded undisturbed in their cages in a prospective, case-control study. Painful cats received analgesic treatment and videos were repeated one hour later. Five action units (AU) were identified: ear position, orbital tightening, muzzle tension, whiskers change and head position. Four observers independently scored (0–2 for each AU) 110 images of control and painful cats. The FGS scores were higher in painful than in control cats; a very strong correlation with another validated instrument for pain assessment in cats was observed (rho = 0.86, p < 0.001) as well as good overall inter-rater reliability [ICC = 0.89 (95% CI: 0.85–0.92)], excellent intra-rater reliability (ICC > 0.91), and excellent internal consistency (Cronbach’s alpha = 0.89). The FGS detected response to analgesic treatment (scores after analgesia were lower than before) and a cut-off score was determined (total pain score > 0.39 out of 1.0). The FGS is a valid and reliable tool for acute pain assessment in cats.

1 September 2013 in Journal of Veterinary Internal Medicine
Verified
Journal Article
Closed access
PDF file
BMBeatriz Monteiro
Beatriz Monteiro
PSPaulo V Steagall
Paulo V Steagall
BLB. Duncan Lascelles
B. Duncan Lascelles

27 October 2022 in Journal of Small Animal Practice
Verified
Journal Article
Closed access
BMBeatriz Monteiro
Beatriz Monteiro
BLB. Duncan Lascelles
B. Duncan Lascelles
JMJ. Murrell
J. Murrell
SRS. Robertson
S. Robertson
PSPaulo V Steagall
Paulo V Steagall
BWB. Wright
B. Wright

1 May 2014 in Journal of Veterinary Internal Medicine
Verified
Journal Article
Open access
PDF file
PSPaulo V Steagall
Paulo V Steagall
BMBeatriz Monteiro
Beatriz Monteiro
PTP.M. Taylor
P.M. Taylor
Pain management is a crucial component of feline medicine and surgery. This review critically evaluates studies using buprenorphine in cats and highlights the clinical application of the opioid in this species. The pharmacokinetic-pharmacodynamic (PK-PD) modeling of IV buprenorphine has been best described by a combined effect compartmental/receptor association-dissociation model with negative hysteresis. Therefore, plasma concentrations of the drug are not correlated with analgesia, and clinicians should not expect to observe pain relief immediately after drug administration. In addition, a ceiling effect has not been demonstrated after administration of clinical doses of buprenorphine in cats; dosages of up to 0.04 mg/kg have been reported. The route of administration influences the onset, duration, and magnitude of antinociception and analgesia when using this drug in cats. At clinical dosages, the SC route of administration does not appear to provide adequate antinociception and analgesia whereas the buccal route has produced inconsistent results. Intravenous or IM administration at a dosage of 0.02–0.04 mg/kg is the preferred for treatment of pain in the acute setting. A literature search found 14 clinical trials evaluating buprenorphine sedation, analgesia, or both in cats. There were 22 original research studies reporting the antinociceptive effects of buprenorphine by means of thermal threshold, mechanical threshold, or both, minimal alveolar concentration, or PK-PD. Individual variability in response to buprenorphine administration has been reported, indicating that buprenorphine may not provide sufficient analgesia in some cats. Pain assessment is important when evaluating the efficacy of buprenorphine and determining whether additional analgesic treatment is needed.

9 September 2021 in Pain
Verified
Journal Article
Closed access
MEMarina C. Evangelista
Marina C. Evangelista
BMBeatriz Monteiro
Beatriz Monteiro
PSPaulo V Steagall
Paulo V Steagall
Facial expressions of pain have been identified in several animal species. The aim of this systematic review was to provide evidence on the measurement properties of grimace scales for pain assessment. The protocol was registered (SyRF#21-November-2019), and the study is reported according to the PRISMA guidelines. Studies reporting the development, validation, and the assessment of measurement properties of grimace scales were included. Data extraction and assessment were performed by 2 investigators, following the COnsensus-based Standards for the Selection of Health Measurement INstruments guidelines. Six categories of measurement properties were assessed: internal consistency, reliability, measurement error, criterion and construct validity, and responsiveness. Overall strength of evidence (high, moderate, and low) of each instrument was based on methodological quality, number of studies, and studies' findings. Twelve scales for 9 species were included (mice, rats, rabbits, horses, piglets, sheep or lamb, ferrets, cats, and donkeys). Considerable variability regarding their development and measurement properties was observed. The Mouse, Rat, Horse and Feline Grimace Scales exhibited high level of evidence. The Rabbit, Lamb, Piglet and Ferret Grimace Scales and Sheep Pain Facial Expression Scale exhibited moderate level of evidence. The Sheep Grimace Scale, EQUUS-FAP, and EQUUS-Donkey-FAP exhibited low level of evidence for measurement properties. Construct validity was the most reported measurement property. Reliability and other forms of validity have been understudied. This systematic review identified gaps in knowledge on the measurement properties of grimace scales. Further studies should focus on improving psychometric testing, instrument refinement, and the use of grimace scales for pain assessment in nonhuman mammals.

12 April 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BMBeatriz Monteiro
Beatriz Monteiro
MKMary P. Klinck
Mary P. Klinck
MMMaxim Moreau
Maxim Moreau
MGMartin Guillot
Martin Guillot
PSPaulo V Steagall
Paulo V Steagall
ETEric Troncy
Eric Troncy
This study aimed to (1) compare outcome assessments in normal and osteoarthritic cats and (2) evaluate the analgesic efficacy of tramadol in feline osteoarthritis (OA), in a prospective, randomised, blinded, placebo-controlled, crossover design. Twenty cats were included after clinical examination, blood work and full body radiographs were performed. In Phase 1, outcome assessments aimed to differentiate normal (n = 5; i.e. exempt of any radiographic and clinical sign of OA) from OA (n = 15) cats. In Phase 2, OA cats were treated twice daily with a placebo (PG: cornstarch 15 mg) or tramadol (TG: 3 mg/kg) orally for 19 days, with a 3-month washout period between treatments. Evaluations were performed in normal and OA cats at baseline and consisted of: 1) peak vertical force (PVF) after staircase exercise; 2) telemetered night-time motor activity (NMA); and 3) response to mechanical temporal summation (RMTS). After treatment, PVF, NMA and RMTS evaluations were repeated in OA cats. Data were analysed with mixed model methods with an alpha-threshold of 5%. Phase 1: 1) PVF (% of body weight; mean ± SD) was higher in normal (59 ± 10.5) than in OA cats (50.6 ± 5.7) (p = 0.005); 2) NMA (no unit) was not different between groups; 3) RMTS (number of stimuli; median (range)) was higher in normal [29.5 (23.5–30)] than in OA cats [14 (8.5–28)] (p < 0.0001). Phase 2: PVF, NMA and RMTS presented a treatment effect (p = 0.024, p = 0.008 and p = 0.018, respectively). No clinically important adverse-effects were observed. Outcome assessments such as kinetics (PVF) and evaluation of central sensitisation (RMTS) are discriminant of OA status. Mobility measured by NMA was not discriminant of OA status, however it increased in OA cats with tramadol treatment. Nociceptive hypersensitivity quantified by RMTS was evident in OA cats and was responsive to tramadol treatment.