oman zuas

oman zuas


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014 in Materials Letters
Verified
Journal Article
Closed access
OZoman zuas
oman zuas
NHNuryatini Hamim
Nuryatini Hamim
YSYulianti Sampora
Yulianti Sampora

1 August 2021 in Chemosphere
Verified
Journal Article
Closed access
ANAndreas
Andreas
Tony HadibarataTony Hadibarata
Tony Hadibarata
PSPalanivel Sathishkumar
Palanivel Sathishkumar
HPHafiizh Prasetia
Hafiizh Prasetia
HIHikmat
Hikmat
ASAjeng Arum Sari
Ajeng Arum Sari

1 January 2014 in Processing and Application of Ceramics
Verified
Journal Article
Open access
OZoman zuas
oman zuas
HAHAZNAN ABIMANYU
HAZNAN ABIMANYU
WWWidayanti Wibowo
Widayanti Wibowo
The nanostructured cerium dioxide (CeO2) has been successfully fabricated using a simple precipitation method. Its characteristics were evaluated using TG-DTA, DR-UV-Vis, XRD, FTIR and TEM. The results showed that the nanostructured CeO2 has high purity and good crystalline nature, with face centered cubic (fcc) phase and the average diameter of CeO2 single crystal about 14 nm. Performance evaluation of the synthesized CeO2 samples showed that the nanostructured CeO2 has a strong adsorption toward acid orange-10 (AO-10) and congo red (CR) in aqueous solution. Under given experimental conditions (dye concentration of 15 mg/l, adsorbent dosage of 1 g/l, reaction temperature of 30 ? 1?C), it was estimated that the adsorption equilibrium for AO-10 and CR occurred at 60 min and 90 min of reaction time, respectively, with total removal of 96.82% for AO-10 dye and 93.55% for CR dye. The results suggested that the CeO2 nanopowder could be potentially used as an efficient adsorbent for the removal of synthetic organic dyes in aqueous solution and may address for future concern in the area.

10 March 2013 in Nano-Micro Letters
Verified
Journal Article
Open access
PDF file
OZoman zuas
oman zuas
HBHarry Budiman
Harry Budiman
Nanostructured pure-TiO2and Cu3%-TiO2were successfully synthesized via co-precipitation method. The X-ray diffraction (XRD) result proves that the synthesized sample were predominantly in anatase phase with size in the range of 8∼16 nm, which are in good agreement with the transmission electron microscopy data. Owing to doping of copper, not only did the thermal stability of the TiO2decrease, but also a significant decrease in its particle size and a shift of the adsorption edge to a higher wavelength region appear. The activity of both pure-TiO2and Cu3%-doped TiO2was tested to study their ability to decolorize congo red (CR) dye in aqueous solution. We observed that the CR dye was decolorized faster by Cu3%-TiO2than pure-TiO2. Results of this study demonstrate a potential application of the synthesized sample for decolorizing dye pollutants from aqueous waste.

1 January 2015 in Procedia Chemistry
Verified
Journal Article
Open access
HBHarry Budiman
Harry Budiman
NUNuryatini
Nuryatini
OZoman zuas
oman zuas
A method comparison between gas chromatography-thermal conductivity detector (GC-TCD) and chromatography-flame ionization detector (GC-FID) for the analysis of propane (C3H8) are reported in this study. To achieve the study purpose for producing valid and reliable result, the method comparison process was conducted by investigating several keys of analytical parameter of both GC-TCD and GC-FID method including method sensitivity, precision, accuracy, and method linearity. Investigation of the GC's parameter were conducted by analyzing the C3H8 (% mol/mol) in nitrogen (N2) balance (known as C3H8 certified reference material). The results show that the GC-FID method was found to display more sensitive, precise, and accurate than GC-TCD method for the analysis of C3H8. The sensitivity of the GC-FID are 66 times higher than GC-TCD method. In addition, the GC-FID exhibits a wider linear range (0.161 -2.18%mol/mol) than the GC-TCD method (0.242 – 2.18%mol/mol)

1 January 2016 in Hemijska industrija
Verified
Journal Article
Open access
PDF file
OZoman zuas
oman zuas
HBHarry Budiman
Harry Budiman
Investigation on precision and accuracy of gas chromatography equipped with thermal conductivity detector (GC-TCD) method for the measurement of CO2, C3H8, and CO as pollutant models at different flow rate of helium (He) carrier gas ranging from 17.50 to 36.25 ml/min were conducted. It was found that percentage of relative standard deviation (%RSD) values for both precision an accuracy show an overall gradual decrease as the carrier gas flow rates increased up to 25 ml/min. After that, the %RSD was found to increase with a further increase in the flow rate. These findings indicate that the flow rate of 25 ml/min was found to be the most precise and accurate level among all flow rates tested under experimental conditions of this study. While the %RSD values obtained at all flow rate are given in details. Consequently, our results suggest that the flow rate of carrier gas was a determining parameter for varying the precision and accuracy of the GC-TCD method. Owing to the fact that carrier gas act as a transporter of components of the mixture in the form of vapor or gas through the column, setting of the flow rate of carrier gas should in proper level achieve a precision and accuracy of the GC-TCD method.