A conventional ground-coupled heat pump (GCHP) can be used to supplement heat rejection or extraction, creating a hybrid system that is cost-effective for certainly unbalanced climes. This research explores the possibility for a hybrid GCHP to use excess heat from a combined heat power (CHP) unit of natural gas in a heating-dominated environment for smart cities. A design for a multi-family residential building is considered, with a CHP sized to meet the average electrical load of the building. The constant electric output of the CHP is used directly, stored for later use in a battery, or sold back to the grid. Part of the thermal output provides the building with hot water, and the rest is channeled into the GCHP borehole array to support the building’s large heating needs. Consumption and weather data are used to predict hourly loads over a year for a specific multi-family residence. Simulations of the energies exchanged between system components are performed, and a cost model is minimized over CHP size, battery storage capacity, number of boreholes, and depth of the borehole. Results indicate a greater cost advantage for the design in a severely heated (Canada) climate than in a moderately imbalanced (Ohio) climate.
Energy savings based upon use of smart WiFi thermostats ranging from 10 to 15% have been documented, as new features such as geofencing have been added. Here, a new benefit of smart WiFi thermostats is identified and investigated; namely, as a tool to improve the estimation accuracy of residential energy consumption and, as a result, estimation of energy savings from energy system upgrades, when only monthly energy consumption is metered. This is made possible from the higher sampling frequency of smart WiFi thermostats. In this study, collected smart WiFi data are combined with outdoor temperature data and known residential geometrical and energy characteristics. Most importantly, unique power spectra are developed for over 100 individual residences from the measured thermostat indoor temperature in each and used as a predictor in the training of a singular machine learning models to predict consumption in any residence. The best model yielded a percentage mean absolute error (MAE) for monthly gas consumption ±8.6%. Applied to two residences to which attic insulation was added, the resolvable energy savings percentage is shown to be approximately 5% for any residence, representing an improvement in the ASHRAE recommended approach for estimating savings from whole-building energy consumption that is deemed incapable at best of resolving savings less than 10% of total consumption. The approach posited thus offers value to utility-wide energy savings measurement and verification.