Microelectromechanical system (MEMS)-based thermal flow sensors are well known for their fast response and compact size in gas flow measurement. Nevertheless, these sensors exhibit superior performance at low gas flow rates, encountering significant limitations in accuracy and anti-disturbance under high gas flow conditions. This paper presents a bypass thermal mass flowmeter (TMF) based on MEMS sensor core that extended the measurement range by optimizing the length and hole diameter of the restrictor to determine the suitable bypass ratio. Meanwhile, by combining the Sage-Husa adaptive robust KF with the strong tracking KF, we propose a Modified Sage-Husa Adaptive Robust-Strong Tracking Kalman Filter (MSHAR-STKF) to ensure high accuracy and rapid response in flow measurement. The results indicate that the flowmeter achieves a measurement range of 0-15 m 2 /h with a relative error within 1.5%. By comparing the Root Mean Square Error (RMSE) and Mean Absolute Error (MAE) of static signals under various disturbances, the MSHAR-STKF exceeds the Kalman Filter (KF), Sage-Husa Adaptive Kalman Filter (SHAKF), Strong Tracking Kalman Filter (STKF), and Adaptive Robust Kalman Filter (ARKF) in suppressing outliers and biases. Additionally, the dynamic response time of MSHAR-STKF is also the fastest among above algorithms with about 1s of rise and fall times.
4 February 2025 in Sensors and Actuators B: Chemical