Air velocity is one of the key parameters affecting the sensation of thermal comfort. In mixing ventilation, the air is most often supplied above the occupied zone, and the air movement in a room is caused by jets that generate recirculating flows. An effective tool for predicting airflow in a room is CFD numerical modeling. In order to reproduce the air velocity distribution, it is essential to select a proper turbulence model. In this paper, seven Eddy–Viscosity RANS turbulence models were used to carry out CFD simulations of a sidewall air jet supplied into a room through a wall diffuser. The goal was to determine which model was the most suitable to adopt in this type of airflow. The CFD results were validated using experimental data by comparing the gross and integral parameters, along with the parameters of the quasi-free jet model. The numerical results obtained for Std k-ε and EVTM models were most consistent with the measurements. Their error values slightly exceeded 15%. On the contrary, the k-ω and RNG k-ε models did not reproduce the quasi-free jet parameters correctly. The research findings can prove beneficial for simulating air distribution in supplied air jets during the initial conceptual phases of HVAC system design.
In mixing ventilation systems, diffusers are often located on side walls and supply quasi-free air jets above the occupied zone. The data presented in this paper shows a new CFD 3D benchmark with two well-defined characteristic zones in the room, i.e., the quasi-free jet zone and the occupied zone. Measurement methods adequate for air velocity and speed measurement were applied: laser Doppler anemometry for the axial velocity component in the jet and low velocity thermal anemometry for the air speed in the occupied zone. Measurements were performed in a physical scale model (1:5) of the room. The kinematic similarity criterion was fulfilled by the equality of the Reynolds numbers in the model and in the prototype. To identify boundary conditions, additional measurements were carried out in the inlet region (as close as possible to the supply opening). The CFD results validation and reporting methods applicable for the benchmark data are proposed in Hurnik et al. (2015) [1].