Morten Andreas Geday

Prof. Morten Andreas Geday

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2003 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
LJLee-Way Jin
Lee-Way Jin
KCKacey A. Claborn
Kacey A. Claborn
MKMiki Kurimoto
Miki Kurimoto
MGMorten Andreas Geday
Morten Andreas Geday
IMIzumi Maezawa
Izumi Maezawa
Bart KahrBart Kahr
Bart Kahr
New advances in polarized light microscopy were used to image Congo red-stained cerebral amyloidosis in sharp relief. The rotating-polarizer method was used to separate the optical effects of transmission, linear birefringence, extinction, linear dichroism, and orientation of the electric dipole transition moments and to display them as false-color maps. These effects are typically convolved in an ordinary polarized light microscope. In this way, we show that the amyloid deposits in Alzheimer's disease plaques contain structurally disordered centers, providing clues to mechanisms of crystallization of amyloid in vivo . Comparisons are made with plaques from tissues of subjects having Down's syndrome and a prion disease. In plaques characteristic of each disease, the Congo red molecules are oriented radially. The optical orientation in amyloid deposited in blood vessels from subjects having cerebral amyloid angiopathy was 90° out of phase from that in the plaques, suggesting that the fibrils run tangentially with respect to the circumference of the blood vessels. Our result supports an early model in which Congo red molecules are aligned along the long fiber axis and is in contrast to the most recent binding models that are based on computation. This investigation illustrates that the latest methods for the optical analysis of heterogeneous substances are useful for in situ study of amyloid.

25 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MCManuel Caño-García
Manuel Caño-García
XQX. Quintana
X. Quintana
JSJOSE MANUEL OTON SANCHEZ
JOSE MANUEL OTON SANCHEZ
MGMorten Andreas Geday
Morten Andreas Geday
The design and characterisation of a reconfigurable multi-level spiral phase plate is shown. The device is based on a pie-shape liquid-crystal structure with 24 slices driven by custom electronics that allow independent excitation control of each electrode. The electrooptical cell was manufactured using maskless laser ablation lithography and has shown an unprecedented high fill factor. The topological charge can be dynamically changed between 1, 2, 3, 4, 6, 8 and 12. The device has been calibrated and characterised at 632.8 nm but can be employed at any wavelength in the visible and near infrared spectrum, just modifying the driving parameters of the electrodes. The experimental results have been compared to predictions derived from simulations. An excellent correspondence between theoretical and experimental result has been found in all cases.

1 January 2002 in Ferroelectrics
Verified
Journal Article
Closed access
GJG. O. Jones
G. O. Jones
JKJ. Kreisel
J. Kreisel
VJV. Jennings
V. Jennings
MGMorten Andreas Geday
Morten Andreas Geday
PTP. A. Thomas
P. A. Thomas
AGA. M. Glazer
A. M. Glazer
The relaxor ferroelectric, Sodium Bismuth Titanate, (Na 0.5 Bi 0.5 TiO 3 ), NBT is an A-site substituted distorted perovskite. An extensive temperature-, pressure- and substitution-dependent study of the crystal structure and phase transitions in this compound has been carried out using neutron/x-ray diffraction techniques. This has been complemented with optical, Raman and computational modelling studies. The temperature-dependent investigation shows that NBT undergoes a first phase transition from the high-temperature cubic prototype (Pm &3macr; m) Phase I to Phase II of tetragonal symmetry (P4bm) and then a second one with strong diffuse character to Phase III of rhombohedral symmetry (R3c). The high-pressure study of NBT has revealed an interesting and unusual relaxor-to-antiferroelectric (R3c M Pnma) phase transition. Structural variations as a function of temperature and doping across the (Na 1 m x K x ) 0.5 Bi 0.5 TiO 3 (NKBT) series have also been established.

6 May 2004 in Journal of Physics: Condensed Matter
Verified
Journal Article
Closed access
MGMorten Andreas Geday
Morten Andreas Geday
AGA M Glazer
A M Glazer

1 October 2018 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
JSJOSE MANUEL OTON SANCHEZ
JOSE MANUEL OTON SANCHEZ
EOEva Oton
Eva Oton
XQXabier Quintana
Xabier Quintana
MGMorten Andreas Geday
Morten Andreas Geday

12 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
CVCésar Vega-Colado
César Vega-Colado
BABelen Arredondo
Belen Arredondo
Juan Carlos Torres ZafraJuan Carlos Torres Zafra
Juan Carlos Torres Zafra
ELEduardo López-Fraguas
Eduardo López-Fraguas
RVRicardo Vergaz
Ricardo Vergaz
JSJose Manuel Sanchez-Pena
Jose Manuel Sanchez-Pena
Visible light communication systems can be used in a wide variety of applications, from driving to home automation. The use of wearables can increase the potential applications in indoor systems to send and receive specific and customized information. We have designed and developed a fully organic and flexible Visible Light Communication system using a flexible OLED, a flexible P3HT:PCBM-based organic photodiode (OPD) and flexible PCBs for the emitter and receiver conditioning circuits. We have fabricated and characterized the I-V curve, modulation response and impedance of the flexible OPD. As emitter we have used a commercial flexible organic luminaire with dimensions 99 × 99 × 0.88 mm, and we have characterized its modulation response. All the devices show frequency responses that allow operation over 40 kHz, thus enabling the transmission of high quality audio. Finally, we integrated the emitter and receiver components and its electronic drivers, to build an all-organic flexible VLC system capable of transmitting an audio file in real-time, as a proof of concept of the indoor capabilities of such a system.