Ambre Dauba

Ms. Ambre Dauba

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
ADAmbre Dauba
Ambre Dauba
ADAnthony Delalande
Anthony Delalande
HKHermes Arytto Salles Kamimura
Hermes Arytto Salles Kamimura
Allegra ContiAllegra Conti
Allegra Conti
BLBenoit Larrat
Benoit Larrat
ANAnthony Novell
Anthony Novell
The blood-brain barrier is the primary obstacle to efficient intracerebral drug delivery. Focused ultrasound, in conjunction with microbubbles, is a targeted and non-invasive way to disrupt the blood-brain barrier. Many commercially available ultrasound contrast agents and agents specifically designed for therapeutic purposes have been investigated in ultrasound-mediated blood-brain barrier opening studies. The new generation of sono-sensitive agents, such as liquid-core droplets, can also potentially disrupt the blood-brain barrier after their ultrasound-induced vaporization. In this review, we describe the different compositions of agents used for ultrasound-mediated blood-brain barrier opening in recent studies, and we discuss the challenges of the past five years related to the optimal formulation of agents.

12 August 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MFMarie-Solenne Felix
Marie-Solenne Felix
EBEmilie Borloz
Emilie Borloz
KMKhaled METWALLY
Khaled METWALLY
ADAmbre Dauba
Ambre Dauba
BLBenoit Larrat
Benoit Larrat
JRJean Christophe Roux
Jean Christophe Roux
Gene therapy represents a powerful therapeutic tool to treat diseased tissues and provide a durable and effective correction. The central nervous system (CNS) is the target of many gene therapy protocols, but its high complexity makes it one of the most difficult organs to reach, in part due to the blood-brain barrier that protects it from external threats. Focused ultrasound (FUS) coupled with microbubbles appears as a technological breakthrough to deliver therapeutic agents into the CNS. While most studies focus on a specific targeted area of the brain, the present work proposes to permeabilize the entire brain for gene therapy in several pathologies. Our results show that, after i.v. administration and FUS sonication in a raster scan manner, a self-complementary AAV9-CMV-GFP vector strongly and safely infected the whole brain of mice. An increase in vector DNA (19.8 times), GFP mRNA (16.4 times), and GFP protein levels (17.4 times) was measured in whole brain extracts of FUS-treated GFP injected mice compared to non-FUS GFP injected mice. In addition to this increase in GFP levels, on average, a 7.3-fold increase of infected cells in the cortex, hippocampus, and striatum was observed. No side effects were detected in the brain of treated mice. The combining of FUS and AAV-based gene delivery represents a significant improvement in the treatment of neurological genetic diseases.

20 October 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
GHGaëlle Hugon
Gaëlle Hugon
SGSébastien Goutal
Sébastien Goutal
ADAmbre Dauba
Ambre Dauba
LBLouise Breuil
Louise Breuil
BLBenoit Larrat
Benoit Larrat
NTNicolas Tournier
Nicolas Tournier
Focused ultrasound in combination with microbubbles (FUS) provides an effective means to locally enhance the delivery of therapeutics to the brain. Translational and quantitative imaging techniques are needed to noninvasively monitor and optimize the impact of FUS on blood-brain barrier (BBB) permeability in vivo. Positron-emission tomography (PET) imaging using [18F]2-fluoro-2-deoxy-sorbitol ([18F]FDS) was evaluated as a small-molecule (paracellular) marker of blood-brain barrier (BBB) integrity. [18F]FDS was straightforwardly produced from chemical reduction of commercial [18F]2-deoxy-2-fluoro-D-glucose. [18F]FDS and the invasive BBB integrity marker Evan’s blue (EB) were i.v. injected in mice after an optimized FUS protocol designed to generate controlled hemispheric BBB disruption. Quantitative determination of the impact of FUS on the BBB permeability was determined using kinetic modeling. A 2.2 ± 0.5-fold higher PET signal (n = 5; p < 0.01) was obtained in the sonicated hemisphere and colocalized with EB staining observed post mortem. FUS significantly increased the blood-to-brain distribution of [18F]FDS by 2.4 ± 0.8-fold (VT; p < 0.01). Low variability (=10.1%) of VT values in the sonicated hemisphere suggests reproducibility of the estimation of BBB permeability and FUS method. [18F]FDS PET provides a readily available, sensitive and reproducible marker of BBB permeability to noninvasively monitor the extent of BBB disruption induced by FUS in vivo.

14 October 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CCCorentin Cornu
Corentin Cornu
LJLaurène Jourdain
Laurène Jourdain
FBFlavien Barcella
Flavien Barcella
LCLaurent Colin
Laurent Colin
ZEZoé Edon
Zoé Edon
ANAnthony Novell
Anthony Novell
Objective. Cavitation dose monitoring plays a key role in ultrasound drug delivery to the brain. The use of capacitive micromachined ultrasonic transducer (CMUT) technology has a great potential for passive cavitation detection (PCD). Approach. Here, a circular (diameter 7 mm) CMUT centered at 5 MHz was designed to be inserted into a therapeutic transducer (1.5 MHz) used for ultrasound-induced blood–brain barrier (BBB) disruption on mice. CMUT-based real-time cavitation detection was performed during the ultrasound procedure (50 μl intravenous injection of SonoVue microbubbles, frequency 1.5 MHz, PNP 480 kPa, duty Cycle 10%, PRF 10 Hz, duration 60 s). BBB disruption were confirmed by contrast-enhanced 7T-MRI. Main results. The CMUT device has a fractional bandwidth of 140%, almost twice a conventional piezocomposite PCD transducer. As expected, the CMUT device was able to detect the occurrence of harmonic, subharmonic and ultraharmonic frequencies as well as the increase of broadband signal indicating inertial cavitation in a wide frequency range (from 0.75 to 6 MHz). Signal-to-noise ratio was high enough (>40 dB) to perform ultrafast monitoring and follow the subtle intrapulse variations of frequency components at a rate of 10 kHz. Significance. This first in vivo proof of concept demonstrates the interest of CMUT for PCD and encourages us to develop devices for PCD in larger animals by integrating an amplifier directly to the CMUT front-end to considerably increase the signal-to-noise ratio.

31 August 2025 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
ADAmbre Dauba
Ambre Dauba
TNThi Hong Van Nguyen
Thi Hong Van Nguyen
TAThomas Ador
Thomas Ador
CSClaire Spitzlei
Claire Spitzlei
EPEstelle Porret
Estelle Porret
ANAnthony Novell
Anthony Novell
Microbubble-mediated focused ultrasound is a promising strategy for transient and localized blood-brain barrier (BBB) permeabilization, enabling drug delivery to the brain. Optimizing microbubble stability and acoustic response is essential to maximize treatment efficiency and minimize potential damage. This study introduces an innovative microbubble formulation with a phospholipid-fluoropolymer shell (LIP-POL), designed to enhance circulation persistence while maintaining a low cavitation threshold. The physicochemical and acoustic properties of LIP-POL microbubbles were systematically compared with phospholipid-shell microbubbles (LIP) and the commercial agent SonoVue®. Both SonoVue and LIP-POL microbubbles have similar concentrations and sizes (approximately 5 × 108 bubbles/mL, mean size of 2.5-2.7 µm), whereas LIP microbubbles are around 100 times more concentrated (7.3 × 1010 bubbles/mL) and slightly smaller (1.9 µm). In vitro, ultra-harmonics appeared at 120 kPa for LIP, 150 kPa for LIP-POL, and 200 kPa for SonoVue (fc = 1 MHz, PRF = 10 kHz, 40 cycles). Consistent with microbubbles' acoustic signature, the BBB opening threshold (fc = 1.5 MHz) occurred at lower Mechanical Indices (MI) for LIP and LIP-POL microbubbles (MI = 0.16) compared to SonoVue (MI = 0.20). Stability of circulating microbubbles was assessed using BBB permeabilization protocol at various time points post microbubble-injection. LIP-POL microbubbles remained effective for up to 15 min post-injection, compared to 7.5 min for LIP and 5 min for SonoVue (2 × 107 microbubbles injected). The prolonged efficacy of LIP-POL microbubbles (three times longer than SonoVue) opens the possibility for extended ultrasound treatments, particularly for BBB permeabilization across larger areas in large animal models or humans.

25 November 2024 in Annals of Work Exposures and Health
Verified
Journal Article
Closed access
PDF file
LTLéa Touri
Léa Touri
ATAdeline Tarantini
Adeline Tarantini
CSCarey Suehs
Carey Suehs
ENErika Nogue
Erika Nogue
CMCaroline Marie-Desvergne
Caroline Marie-Desvergne
NMNicolas Molinari
Nicolas Molinari
As differential exposure to airport-generated aerosols may affect employee lung function, the main objective of this study was to longitudinally evaluate spirometry measures among Air France employees. In addition, an exploratory exposure assessment to airport aerosol was performed in a small cohort of workers using personal monitoring devices. Change in lung function over a ~6.6-yr period was documented for office workers (n = 68) and mechanics (n = 83) at Paris-Roissy airport, France and terminal (n = 29), or apron (n = 35) workers at Marseille airport, France. Overall, an excessive decline in lung function was found for 24.75% of airport workers; excessive decline occurred more often for terminal workers (44.83%) as compared to mechanics (14.47%; P = 0.0056), with a similar tendency for apron workers (35.29%) as compared to mechanics (P = 0.0785). Statistically significant differences/tendencies were detected among the yearly rates of change for %-predicted values of forced expiratory volume in 1 s, forced vital capacity, peak expiratory flow, and from 25% to 75% forced expiratory flow. For the latter variables, the terminal and/or apron workers at Marseille generally had significantly faster lung function decline as compared to office workers and/or mechanics in Paris, although the latter were exposed to a higher level of elemental carbon. No relation between lung function decline and exposure to airport tarmac environments was evidenced. Multivariate exploration of individual variables representing sex, smoking, atopy, respiratory disease, residential PM2.5 pollution, the peak size of particles in lung exhalates or exhaled carbon monoxide at the time of follow-up failed to explain the observed differences. In conclusion, this study documents the first evidence of excessive lung function decline among certain airport workers in France, although the identification of emission sources (environmental factors, aircraft exhaust, etc) remains challenging.