Lei Dong

Dr. Lei Dong

Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
DKDeborah A. Kuban
Deborah A. Kuban
STSusan L. Tucker
Susan L. Tucker
Lei DongLei Dong
Lei Dong
GSGeorge Starkschall
George Starkschall
EHEugene H. Huang
Eugene H. Huang
APAlan Pollack
Alan Pollack

1 July 2004 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JBJerry L. Barker
Jerry L. Barker
AGAdam S. Garden
Adam S. Garden
KAK.KIan Ang
K.KIan Ang
JOJennifer C. O'DAniel
Jennifer C. O'DAniel
HWHe Wang
He Wang
Lei DongLei Dong
Lei Dong

1 June 2005 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
HWHe Wang
He Wang
Lei DongLei Dong
Lei Dong
JOJennifer O'DAniel
Jennifer O'DAniel
RMRadhe Mohan
Radhe Mohan
AGAdam S Garden
Adam S Garden
RCRex Cheung
Rex Cheung
A greyscale-based fully automatic deformable image registration algorithm, originally known as the 'demons' algorithm, was implemented for CT image-guided radiotherapy. We accelerated the algorithm by introducing an 'active force' along with an adaptive force strength adjustment during the iterative process. These improvements led to a 40% speed improvement over the original algorithm and a high tolerance of large organ deformations. We used three methods to evaluate the accuracy of the algorithm. First, we created a set of mathematical transformations for a series of patient's CT images. This provides a 'ground truth' solution for quantitatively validating the deformable image registration algorithm. Second, we used a physically deformable pelvic phantom, which can measure deformed objects under different conditions. The results of these two tests allowed us to quantify the accuracy of the deformable registration. Validation results showed that more than 96% of the voxels were within 2 mm of their intended shifts for a prostate and a head-and-neck patient case. The mean errors and standard deviations were 0.5 mm+/-1.5 mm and 0.2 mm+/-0.6 mm, respectively. Using the deformable pelvis phantom, the result showed a tracking accuracy of better than 1.5 mm for 23 seeds implanted in a phantom prostate that was deformed by inflation of a rectal balloon. Third, physician-drawn contours outlining the tumour volumes and certain anatomical structures in the original CT images were deformed along with the CT images acquired during subsequent treatments or during a different respiratory phase for a lung cancer case. Visual inspection of the positions and shapes of these deformed contours agreed well with human judgment. Together, these results suggest that the accelerated demons algorithm has significant potential for delineating and tracking doses in targets and critical structures during CT-guided radiotherapy.

16 February 2011 in Medical Physics
Verified
Journal Article
Closed access
DLDaniel Low
Daniel Low
JMJean M. Moran
Jean M. Moran
JDJames F. Dempsey
James F. Dempsey
Lei DongLei Dong
Lei Dong
MOMark Oldham
Mark Oldham

31 May 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
HWHongpeng Wu
Hongpeng Wu
Lei DongLei Dong
Lei Dong
HZHuadan Zheng
Huadan Zheng
YYYajun Yu
Yajun Yu
WMWeiguang Ma
Weiguang Ma
FTFrank K. Tittel
Frank K. Tittel
Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a sensitive gas detection technique which requires frequent calibration and has a long response time. Here we report beat frequency (BF) QEPAS that can be used for ultra-sensitive calibration-free trace-gas detection and fast spectral scan applications. The resonance frequency and Q-factor of the quartz tuning fork (QTF) as well as the trace-gas concentration can be obtained simultaneously by detecting the beat frequency signal generated when the transient response signal of the QTF is demodulated at its non-resonance frequency. Hence, BF-QEPAS avoids a calibration process and permits continuous monitoring of a targeted trace gas. Three semiconductor lasers were selected as the excitation source to verify the performance of the BF-QEPAS technique. The BF-QEPAS method is capable of measuring lower trace-gas concentration levels with shorter averaging times as compared to conventional PAS and QEPAS techniques and determines the electrical QTF parameters precisely.

1 July 2005 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
RCRenaud de Crevoisier
Renaud de Crevoisier
STSusan L. Tucker
Susan L. Tucker
Lei DongLei Dong
Lei Dong
RMRadhe Mohan
Radhe Mohan
RCRex Cheung
Rex Cheung
DKDeborah A. Kuban
Deborah A. Kuban