Wen-Fong Wang

Prof. Dr. Wen-Fong Wang

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2015 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
CYChing-Yu Yang
Ching-Yu Yang
WWWen-Fong Wang
Wen-Fong Wang

28 June 2017 in Personal and Ubiquitous Computing
Verified
Journal Article
Closed access
PDF file
WWWen-Fong Wang
Wen-Fong Wang
CYChing-Yu Yang
Ching-Yu Yang
YWYan-Fu Wu
Yan-Fu Wu

2 September 2011 in Sensors
Verified
Journal Article
Open access
PDF file
WWWei-Song Wang
Wei-Song Wang
HHHong-Yi Huang
Hong-Yi Huang
SCShu-Chun Chen
Shu-Chun Chen
KHKuo-Chuan Ho
Kuo-Chuan Ho
Chia-Yu LinChia-Yu Lin
Chia-Yu Lin
CLChing-Hsing Luo
Ching-Hsing Luo
A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC), a microcontroller unit (MCU), a graphical user interface (GUI), and a radio frequency (RF) transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA) to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA). The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR) greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment), a small size of 5.6 cm × 8.7 cm, high portability, and high integration.

13 May 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
WLWei-Chih Lien
Wei-Chih Lien
CCCongo Tak-Shing Ching
Congo Tak-Shing Ching
ZLZheng-Wei Lai
Zheng-Wei Lai
Hui-Min David WangHui-Min David Wang
Hui-Min David Wang
JLJhih-Siang Lin
Jhih-Siang Lin
WWWen-Fong Wang
Wen-Fong Wang
This study aimed to use the k-nearest neighbor (kNN) algorithm, which combines gait stability and symmetry derived from a normalized cross-correlation (NCC) analysis of acceleration signals from the bilateral ankles of older adults, to assess fall risk. Fifteen non-fallers and 12 recurrent fallers without clinically significant musculoskeletal and neurological diseases participated in the study. Sex, body mass index, previous falls, and the results of the 10 m walking test (10 MWT) were recorded. The acceleration of the five gait cycles from the midsection of each 10 MWT was used to calculate the unilateral NCC coefficients for gait stability and bilateral NCC coefficients for gait symmetry, and then kNN was applied for classifying non-fallers and recurrent fallers. The duration of the 10 MWT was longer among recurrent fallers than it was among non-fallers (p < 0.05). Since the gait signals were acquired from tri-axial accelerometry, the kNN F1 scores with the x-axis components were 92% for non-fallers and 89% for recurrent fallers, and the root sum of squares (RSS) of the signals was 95% for non-fallers and 94% for recurrent fallers. The kNN classification on gait stability and symmetry revealed good accuracy in terms of distinguishing non-fallers and recurrent fallers. Specifically, it was concluded that the RSS-based NCC coefficients can serve as effective gait features to assess the risk of falls.

1 March 2017 in Medicine
Verified
Journal Article
Open access
PDF file
WLWei-Chih Lien
Wei-Chih Lien
YCYung-Heng Cheng
Yung-Heng Cheng
TKTa-Shen Kuan
Ta-Shen Kuan
YZYu-Lun Zheng
Yu-Lun Zheng
CHChao-Hsien Hsieh
Chao-Hsien Hsieh
WWWen-Fong Wang
Wen-Fong Wang
To compare the degree of gait symmetry of chronic poststroke fallers with that of nonfallers during level walking using triaxial accelerometry. In this cross-sectional study, a total of 14 patients with chronic stroke were recruited from a community hospital from February 2015 to July 2016. Patient characteristics, including the number of falls in the previous 12 months, were obtained from medical records. The Berg Balance Scale (BBS) and timed up and go (TUG) test were used at the onset of the study. Triaxial accelerometers were attached to the back and bilateral lower extremities of each subject with sampling rates of 120 Hz. The cross-correlation between the acceleration signals of the affected and unaffected feet was measured to assess the degree of gait symmetry. The triaxial acceleration signals of the 5 consecutive and bilateral strides from the middle of each trial were processed to measure the cross-correlation and time delay (Ts) between the magnitude of the acceleration vector of the affected and unaffected foot. After controlling for possible confounding factors, the mixed-effect models showed that cross-correlation was significantly higher among nonfallers than fallers (β = −0.093; standard error [SE] = 0.029; P-value = 0.002), and that the Ts was significantly longer among fallers than nonfallers (β = −1.900; SE = 0.719; P-value = 0.011). Cross-correlation and Ts between the affected and unaffected lower extremities may be useful indicators to distinguish poststroke fallers from nonfallers.

13 November 2024 in BMC Geriatrics
Verified
Journal Article
Open access
PDF file
CSChien-Yao Sun
Chien-Yao Sun
LHLin-Chieh Hsu
Lin-Chieh Hsu
CSChien-Chou Su
Chien-Chou Su
CLChung-Yi Li
Chung-Yi Li
CCChia-Ter Chao
Chia-Ter Chao
WLWei-Chih Lien
Wei-Chih Lien
Background: Sarcopenia, gait disturbance, and intradialytic hypotension are among the various factors that contribute to fall risk. This study aimed to investigate the relationship between risk of sarcopenia, hemodialysis (HD) session, and long-term fall risk in older end-stage kidney disease (ESKD) patients by analyzing their spatiotemporal gait characteristics. Methods: We recruited 22 non-demented patients aged ≥ 65 years who were undergoing maintenance HD. Participants were divided into two groups based on their SARC-F score (< 4 and ≥ 4) to identify those with higher and lower risk of sarcopenia. Demographics, comorbidities, and renal parameters were compared between groups. Inertial measurement unit-based technology equipped with triaxial accelerometry and gyroscope was used to evaluate gait characteristics. The gait task was assessed both before and after dialysis using the Timed-Up and Go (TUG) test and a 10-meter walking test at a regular pace. Essential gait parameters were thoroughly analyzed, including gait speed, stride time, stride length, double-support phase, stability, and symmetry. We investigated the interaction between the dialysis procedure and gait components. Outcome of interest was any occurrence of injurious fall during follow-up period. Logistic regression models were employed to examine the relationship between baseline gait markers and long-term fall risk. Results: The SARC-F ≥ 4 group showed various gait abnormalities, including longer TUG time, slower gait speed, longer stride time, shorter stride length, and longer double support time compared to counterpart (SARC-F < 4). After HD sessions, the SARC-F ≥ 4 group showed a 2.0-second decrease in TUG task time, an 8.0 cm/s increase in gait speed, an 11.6% lower stride time, and a 2.4% increase in gait symmetry with significant group-time interactions. Shorter stride length and longer double support time were associated with injurious falls during the two-year follow-up. Conclusion: Our study demonstrated the utility of triaxial accelerometers in extracting gait characteristics in older HD patients. High-risk sarcopenia (SARC-F ≥ 4) was associated with various gait abnormalities, some of which partially improved after HD sessions. These gait abnormalities were predictive of future falls, highlighting their prognostic significance.