Keivan Maghooli

Keivan Maghooli


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2022 in Cognitive Neurodynamics
Verified
Journal Article
Closed access
PDF file
SBSara Bagherzadeh
Sara Bagherzadeh
KMKeivan Maghooli
Keivan Maghooli
ASAhmad Shalbaf
Ahmad Shalbaf
AMArash Maghsoudi
Arash Maghsoudi

1 October 2018 in International Clinical Neuroscience Journal
Verified
Journal Article
Open access
PDF file
MSMorteza Zangeneh Soroush
Morteza Zangeneh Soroush
KMKeivan Maghooli
Keivan Maghooli
SSSeyed Kamaledin Setarehdan
Seyed Kamaledin Setarehdan
ANAli Motie Nasrabadi
Ali Motie Nasrabadi
Background: Emotion recognition, as a subset of affective computing, has received considerable attention in recent years. Emotions are key to human-computer interactions. Electroencephalogram (EEG) is considered a valuable physiological source of information for classifying emotions. However, it has complex and chaotic behavior. Methods: In this study, an attempt is made to extract important nonlinear features from EEGs with the aim of emotion recognition. We also take advantage of machine learning methods such as evolutionary feature selection methods and committee machines to enhance the classification performance. Classification performed concerning both arousal and valence factors. Results: Results suggest that the proposed method is successful and comparable to the previous works. A recognition rate equal to 90% achieved, and the most significant features reported. We apply the final classification scheme to 2 different databases including our recorded EEGs and a benchmark dataset to evaluate the suggested approach. Conclusion: Our findings approve of the effectiveness of using nonlinear features and a combination of classifiers. Results are also discussed from different points of view to understand brain dynamics better while emotion changes. This study reveals useful insights about emotion classification and brain-behavior related to emotion elicitation.

1 January 2014 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
SHSepideh Hatamikia
Sepideh Hatamikia
KMKeivan Maghooli
Keivan Maghooli
ANAli Motie Nasrabadi
Ali Motie Nasrabadi
Electroencephalogram (EEG) is one of the useful biological signals to distinguish different brain diseases and mental states. In recent years, detecting different emotional states from biological signals has been merged more attention by researchers and several feature extraction methods and classifiers are suggested to recognize emotions from EEG signals. In this research, we introduce an emotion recognition system using autoregressive (AR) model, sequential forward feature selection (SFS) and K-nearest neighbor (KNN) classifier using EEG signals during emotional audio-visual inductions. The main purpose of this paper is to investigate the performance of AR features in the classification of emotional states. To achieve this goal, a distinguished AR method (Burg's method) based on Levinson-Durbin's recursive algorithm is used and AR coefficients are extracted as feature vectors. In the next step, two different feature selection methods based on SFS algorithm and Davies-Bouldin index are used in order to decrease the complexity of computing and redundancy of features; then, three different classifiers include KNN, quadratic discriminant analysis and linear discriminant analysis are used to discriminate two and three different classes of valence and arousal levels. The proposed method is evaluated with EEG signals of available database for emotion analysis using physiological signals, which are recorded from 32 participants during 40 1 min audio visual inductions. According to the results, AR features are efficient to recognize emotional states from EEG signals, and KNN performs better than two other classifiers in discriminating of both two and three valence/arousal classes. The results also show that SFS method improves accuracies by almost 10-15% as compared to Davies-Bouldin based feature selection. The best accuracies are %72.33 and %74.20 for two classes of valence and arousal and %61.10 and %65.16 for three classes, respectively.

1 June 2019 in Medical Hypotheses
Verified
Journal Article
Closed access
MSMorteza Zangeneh Soroush
Morteza Zangeneh Soroush
KMKeivan Maghooli
Keivan Maghooli
SSSeyed Kamaledin Setarehdan
Seyed Kamaledin Setarehdan
ANAli Motie Nasrabadi
Ali Motie Nasrabadi

21 August 2017 in Neurophotonics
Verified
Journal Article
Closed access
ZEZahra Einalou
Zahra Einalou
KMKeivan Maghooli
Keivan Maghooli
SSSeyaed Kamaledin Setarehdan
Seyaed Kamaledin Setarehdan
AAAta Akin
Ata Akin
Functional near-infrared spectroscopy (fNIRS) has been proposed as an affordable, fast, and robust alternative to many neuroimaging modalities yet it still has long way to go to be adapted in the clinic. One request from the clinicians has been the delivery of a simple and straightforward metric (a so-called biomarker) from the vast amount of data a multichannel fNIRS system provides. We propose a simple-straightforward signal processing algorithm derived from fNIRS-HbO2 data collected during a modified version of the color-word matching Stroop task that consists of three different conditions. The algorithm starts with a wavelet-transform-based preprocessing, then uses partial correlation analysis to compute the functional connectivity matrices at each condition and then computes the global efficiency values. To this end, a continuous wave 16 channels fNIRS device (ARGES Cerebro, Hemosoft Inc., Turkey) was used to measure the changes in HbO2 concentrations from 12 healthy volunteers. We have considered 10% of strongest connections in each network. A strong Stroop interference effect was found between the incongruent against neutral condition (p=0.01) while a similar significance was observed for the global efficiency values decreased from neutral to congruent to incongruent conditions [F(2,33)=3.46, p=0.043]. The findings bring us closer to delivering a biomarker derived from fNIRS data that can be reliably and easily adopted by the clinicians.

1 March 2016 in Optik
Verified
Journal Article
Closed access
ZEZahra Einalou
Zahra Einalou
KMKeivan Maghooli
Keivan Maghooli
SSSeyed Kamaledin Setarehdan
Seyed Kamaledin Setarehdan
AAAta Akin
Ata Akin