Esther Udabe

Ms. Esther Udabe

POLYMAT - University of the Basque Country UPV/EHU
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2017 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
EUEsther Udabe
Esther Udabe
MIMehmet Isik
Mehmet Isik
Haritz SardonHaritz Sardon
Haritz Sardon
LILourdes Irusta
Lourdes Irusta
MSMaitane Salsamendi
Maitane Salsamendi
David MecerreyesDavid Mecerreyes
David Mecerreyes

29 July 2019 in Chemistry of Materials
Verified
Journal Article
Open access
CPChristopher M. Proctor
Christopher M. Proctor
CCChung Yuen Chan
Chung Yuen Chan
Luca PorcarelliLuca Porcarelli
Luca Porcarelli
EUEsther Udabe
Esther Udabe
ASAna Sanchez-Sanchez
Ana Sanchez-Sanchez
GMGeorge Malliaras
George Malliaras
Local drug delivery directly to the source of a given pathology using retrodialysis is a promising approach to treating otherwise untreatable diseases. As the primary material component in retrodialysis, the semipermeable membrane represents a critical point for innovation. This work presents a new ionic hydrogel based on polyethylene glycol and acrylate with dopamine counterions. The ionic hydrogel membrane is shown to be a promising material for controlled diffusive delivery of dopamine. The ionic nature of the membrane accelerates uptake of cationic species compared to a nonionic membrane of otherwise similar composition. It is demonstrated that the increased uptake of cations can be exploited to confer an accelerated transport of cationic species between reservoirs as is desired in retrodialysis applications. This effect is shown to enable nearly 10-fold increases in drug delivery rates from low concentration solutions. The processability of the membrane is found to allow for integration with microfabricated devices which will in turn accelerate adaptation into both existing and emerging device modalities. It is anticipated that a similar materials design approach may be broadly applied to a variety of cationic and anionic compounds for drug delivery applications ranging from neurological disorders to cancer.

17 June 2020 in Materials Advances
Verified
Journal Article
Open access
PDF file
EUEsther Udabe
Esther Udabe
Maria ForsythMaria Forsyth
Maria Forsyth
ASAnthony Somers
Anthony Somers
David MecerreyesDavid Mecerreyes
David Mecerreyes
Mild steel is used extensively in infrastructure and its corrosion susceptibility is a severe issue both economically and with regards to safety. The toxicity of traditional chromate inhibitors requires the discovery of new non-toxic anti-corrosion solutions. Here we show metal-free organic ionic liquids that can be used as direct anodic and cathodic corrosion inhibitors or incorporated into a polymer coating. New p-coumarate methacrylic UV curable ionic liquids that can be used as direct corrosion inhibitors or incorporated into a polymer coating are reported.

6 November 2020 in Polymers
Verified
Journal Article
Open access
PDF file
EUEsther Udabe
Esther Udabe
ASAnthony Somers
Anthony Somers
Maria ForsythMaria Forsyth
Maria Forsyth
David MecerreyesDavid Mecerreyes
David Mecerreyes
Chromate free corrosion inhibitors are searched for to mitigate the economic loss caused by mid-steel corrosion. Here, we show metal-free organic inhibitors having free coumarate anions that can be used either as direct corrosion inhibitors or incorporated into a polymer coating obtained by UV-curing. Four different ionic liquid monomers and polymer coatings with hexoxycoumarate anion and different polymerizable counter cations were investigated. Potentiodynamic polarization, electrochemical impedance spectroscopy, and surface analyses have verified their corrosion inhibition performance on a mild steel AS1020 surface. In the case of the coumarate ionic liquid monomers, the most promising inhibitor is the one coupled with the ammonium cation, showing an inhibition efficiency of 99.1% in solution followed by the imidazolium, pyridinium, and anilinium. Next, the ionic liquid monomers were covalently integrated into an acrylic polymer coating by UV-photopolymerization. In this case, the barrier effect of the polymer coating is combined with the corrosion inhibitor effect of the pendant coumarate anion. Here, the best polymer coatings are those containing 20% imidazolium and pyridinium cations, presenting a greater impedance in the EIS (Electrochemical Impedance Spectroscopy) measurements and less evidence of corrosion in the scribe tests. This article shows that the cationic moiety of coumarate based ionic liquids and poly(ionic liquid)s has a significant effect on their excellent corrosion inhibition properties for a mild steel surface exposed to aqueous chloride solutions.

10 April 2021 in Advanced Science
Verified
Journal Article
Open access
PDF file
SCShao-Tuan Chen
Shao-Tuan Chen
MRMegan N. Renny
Megan N. Renny
Liliana ToméLiliana Tomé
Liliana Tomé
Jorge L. Olmedo-MartínezJorge L. Olmedo-Martínez
Jorge L. Olmedo-Martínez
EUEsther Udabe
Esther Udabe
CPChristopher M. Proctor
Christopher M. Proctor
Implantable electrophoretic drug delivery devices have shown promise for applications ranging from treating pathologies such as epilepsy and cancer to regulating plant physiology. Upon applying a voltage, the devices electrophoretically transport charged drug molecules across an ion‐conducting membrane out to the local implanted area. This solvent‐flow‐free “dry” delivery enables controlled drug release with minimal pressure increase at the outlet. However, a major challenge these devices face is limiting drug leakage in their idle state. Here, a method of reducing passive drug leakage through the choice of the drug co‐ion is presented. By switching acetylcholine's associated co‐ion from chloride to carboxylate co‐ions as well as sulfopropyl acrylate‐based polyanions, steady‐state drug leakage rate is reduced up to sevenfold with minimal effect on the active drug delivery rate. Numerical simulations further illustrate the potential of this method and offer guidance for new material systems to suppress passive drug leakage in electrophoretic drug delivery devices.