Zhen Ding

Mr. Zhen Ding


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ZDZhen Ding
Zhen Ding
CYChifu Yang
Chifu Yang
ZWZhipeng Wang
Zhipeng Wang
XYXunfeng Yin
Xunfeng Yin
Feng JiangFeng Jiang
Feng Jiang
Accurate and reliable motion intention perception and prediction are keys to the exoskeleton control system. In this paper, a motion intention prediction algorithm based on sEMG signal is proposed to predict joint angle and heel strike time in advance. To ensure the accuracy and reliability of the prediction algorithm, the proposed method designs the sEMG feature extraction network and the online adaptation network. The feature extraction utilizes the convolution autoencoder network combined with muscle synergy characteristics to get the high-compression sEMG feature to aid motion prediction. The adaptation network ensures the proposed prediction method can still maintain a certain prediction accuracy even the sEMG signals distribution changes by adjusting some parameters of the feature extraction network and the prediction network online. Ten subjects were recruited to collect surface EMG data from nine muscles on the treadmill. The proposed prediction algorithm can predict the knee angle 101.25 ms in advance with 2.36 degrees accuracy. The proposed prediction algorithm also can predict the occurrence time of initial contact 236±9 ms in advance. Meanwhile, the proposed feature extraction method can achieve 90.71±3.42% accuracy of sEMG reconstruction and can guarantee 73.70±5.01% accuracy even when the distribution of sEMG is changed without any adjustment. The online adaptation network enhances the accuracy of sEMG reconstruction of CAE to 87.65±3.83% and decreases the angle prediction error from 4.03∘ to 2.36∘. The proposed method achieves effective motion prediction in advance and alleviates the influence caused by the non-stationary of sEMG.

20 June 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
ZWZhipeng Wang
Zhipeng Wang
CYChifu Yang
Chifu Yang
Shengping ZhangShengping Zhang
Shengping Zhang
SZShihao Zhang
Shihao Zhang
CYChunzhi Yi
Chunzhi Yi
Feng JiangFeng Jiang
Feng Jiang
The knee has gradually become an important research target for the lower extremity exoskeleton. However, the issue that whether the flexion-assisted profile based on the contractile element (CE) is effective throughout the gait is still a research gap. In this study, we first analyze the effective flexion-assisted method through the passive element’s (PE) energy storage and release mechanism. Specifically, ensuring assisting within an entire joint power period and the human’s active movement is a prerequisite for the CE-based flexion-assisted method. Second, we design the enhanced adaptive oscillator (EAO) to ensure the human’s active movement and the integrity of the assistance profile. Third, a fundamental frequency estimation based on discrete Fourier transform (DFT) is proposed to shorten the convergence time of EAO significantly. The finite state machine (FSM) is designed to improve the stability and practicality of EAO. Finally, we demonstrate the effectiveness of the prerequisite condition for the CE-based flexion-assisted method by using electromyography (EMG) and metabolic indicators in experiments. In particular, for the knee joint, CE-based flexion assistance should be within an entire joint power period rather than just in the negative power phase. Ensuring the human’s active movement will also significantly reduce the activation of antagonistic muscles. This study will aid in designing assistive methods from the perspective of natural human actuation and apply the EAO to the human-exoskeleton system.

18 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CYChunzhi Yi
Chunzhi Yi
SRSeungmin Rho
Seungmin Rho
BWBaichun Wei
Baichun Wei
CYChifu Yang
Chifu Yang
ZDZhen Ding
Zhen Ding
Feng JiangFeng Jiang
Feng Jiang
Inertial measurement units (IMUs) increasingly function as a basic component of a wearable sensor network (WSN). The IMU-based joint angle estimation (JAE) is a typical usage of IMUs for WSN, with extensive applications. However, the issue that IMUs move with respect to their original placement during JAE is still a research gap and limits the robustness of deploying the technique in real-world application scenarios. In this study, we propose to detect and correct the IMU movement online in a computationally lightweight manner. In particular, we first experimentally investigate the influence of IMU movements. Second, we design the metrics for detecting IMU movements by mathematically formulating how the IMU movement affects the IMU’s measurements. Third, we determine the optimal thresholds of metrics by synthetic IMU data from a significantly amended simulation model. Finally, a correction method is proposed to correct the effects of IMU movements. We demonstrate our method on both synthetic data and real-user data. Our proposed method achieves a detection rate of 94.8%, a misdetection rate of 9.8%, and the calculation time of 2.15 ms for detecting IMU movements and can restore the accuracy of JAE. All of the results significantly outperform the intuitive method. The results demonstrate our method is a promising solution to detect and correct IMU movements during JAE. This study will aid the deployment of IMU-based JAE in real-world applications.

29 July 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CYChunzhi Yi
Chunzhi Yi
BWBaichun Wei
Baichun Wei
ZDZhen Ding
Zhen Ding
CYChifu Yang
Chifu Yang
zhiyuan chenzhiyuan chen
zhiyuan chen
Feng JiangFeng Jiang
Feng Jiang
Inertial measurement unit (IMU)-based lower-limb joint angle estimation (JAE) that enables wearable and real-time monitoring of kinematic and biomechanical states has been studied for decades. However, 3-degree-of-freedom (DoF) JAE of lower-limb joints still requires cumbersome calibration procedures. In this article, we propose a self-aligned method by formulating a universal 3-DoF kinematic constraint and solving it by dividing it into three subproblems. Particularly, we divide the issue of optimizing the 3-DoF kinematic constraint by: 1) estimating the main axis following a widely adopted hinge-joint assumption; 2) unifying the reference frames according to a comprehensive metric; and 3) estimating the rest two joint axes. By estimating the coordinates of the three rotational axes of the 3-DoF joint, we further estimate the 3-DoF joint angles by decoupling the joint’s rotations into rotations around the axes. We evaluate our method by accuracy comparison with other methods, test–retest reliability, and ablation experiments. The performance demonstrates that the RMSEs of our method are below 2.9° for hip and knee, below 2.6° for ankle, which are comparable with other methods and able to estimate 3-DoF angles in a self-aligned manner. The agreement between test and retest is good, and the ablation experiments demonstrate the effectiveness of sequentially solving the three subproblems. The proposed method is feasible for self-aligned JAE of 3-DoF lower-limb joints. This study may aid the wider application of IMU-based JAE in field conditions and provide a powerful component for wearable human intent decoding.

28 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ZWZhipeng Wang
Zhipeng Wang
CYChifu Yang
Chifu Yang
ZDZhen Ding
Zhen Ding
TYTao Yang
Tao Yang
HGHao Guo
Hao Guo
BTBowen Tian
Bowen Tian
The advantages of exoskeletons based on the Bowden cable include being lightweight and flexible, thus being convenient in assisting humans. However, the performance of an exoskeleton is limited by the structure and human–exoskeleton interaction, which is analyzed from the established mathematical model of the human–exoskeleton system. In order to improve the auxiliary accuracy, corresponding control methods are proposed. The disturbance observer is designed to compensate for disturbances and parameter perturbations in the inner loop. The human–exoskeleton interaction feedforward model is integrated into the admittance control, which overcomes the limitation of the force loading caused by the friction of the Bowden cable and the change in stiffness of the human–exoskeleton interaction. Furthermore, an angle prediction method using the encoder as the signal source is designed to reduce the disturbance of the force loading caused by human motion. Finally, the effectiveness of the design method proposed in this paper is verified through experiments.

24 May 2021 in Actuators
Verified
Journal Article
Open access
PDF file
ZWZhipeng Wang
Zhipeng Wang
SRSeungmin Rho
Seungmin Rho
CYChifu Yang
Chifu Yang
Feng JiangFeng Jiang
Feng Jiang
ZDZhen Ding
Zhen Ding
BWBaichun Wei
Baichun Wei
Exoskeletons with a Bowden cable for power transmission have the advantages of a concentrated mass and flexible movement. However, their integrated motor is disturbed by the Bowden cable’s friction, which limits the performance of the force loading response. In this paper, we solve this problem by designing an outer-loop feedforward-feedback proportion-differentiation controller based on an inner loop disturbance observer. Firstly, the inner loop’s dynamic performance is equivalent to the designed nominal model using the proposed disturbance observer, which effectively compensates for the parameter perturbation and friction disturbance. Secondly, based on an analysis of the stability of the inner loop controller, we obtain the stability condition and discuss the influence of modeling errors on the inner loop’s dynamic performance. Thirdly, to avoid excessive noise from the force sensors being introduced into the designed disturbance observer, we propose the feedforward-feedback proportion-differentiation controller based on the nominal model and pole configuration, which improves the outer loop’s force loading performance. Experiments are conducted, which verify the effectiveness of the proposed methods.