We report on an experimental characterization of the spatial resolution of a commercial X-ray micro-computed tomography scanner. We have measured the full modulation transfer function (MTF) to assess the spatial resolution. The MTF and those spatial frequencies corresponding to a contrast loss of 50% were determined as a function of different applied X-ray tube parameters and magnification-dependent pixel sizes. A significant influence of the focal spot enlargement on the achievable spatial resolution could be shown. Our results allow for the designation of optimal X-ray tube parameters for a specific application requirement.
Objectives: We hypothesized that published performances of algorithms for artificial intelligence (AI) pneumothorax (PTX) detection in chest radiographs (CXRs) do not sufficiently consider the influence of PTX size and confounding effects caused by thoracic tubes (TTs). Therefore, we established a radiologically annotated benchmarking cohort (n = 6446) allowing for a detailed subgroup analysis. Materials and Methods: We retrospectively identified 6434 supine CXRs, among them 1652 PTX-positive cases and 4782 PTX-negative cases. Supine CXRs were radiologically annotated for PTX size, PTX location, and inserted TTs. The diagnostic performances of 2 AI algorithms (“AI_CheXNet” [Rajpurkar et al], “AI_1.5” [Guendel et al]), both trained on publicly available datasets with labels obtained from automatic report interpretation, were quantified. The algorithms' discriminative power for PTX detection was quantified by the area under the receiver operating characteristics (AUROC), and significance analysis was based on the corresponding 95% confidence interval. A detailed subgroup analysis was performed to quantify the influence of PTX size and the confounding effects caused by inserted TTs. Results: Algorithm performance was quantified as follows: overall performance with AUROCs of 0.704 (AI_1.5) / 0.765 (AI_CheXNet) for unilateral PTXs, AUROCs of 0.666 (AI_1.5) / 0.722 (AI_CheXNet) for unilateral PTXs smaller than 1 cm, and AUROCs of 0.735 (AI_1.5) / 0.818 (AI_CheXNet) for unilateral PTXs larger than 2 cm. Subgroup analysis identified TTs to be strong confounders that significantly influence algorithm performance: Discriminative power is completely eliminated by analyzing PTX-positive cases without TTs referenced to control PTX-negative cases with inserted TTs. Contrarily, AUROCs increased up to 0.875 (AI_CheXNet) for large PTX-positive cases with inserted TTs referenced to control cases without TTs. Conclusions: Our detailed subgroup analysis demonstrated that the performance of established AI algorithms for PTX detection trained on public datasets strongly depends on PTX size and is significantly biased by confounding image features, such as inserted TTS. Our established, clinically relevant and radiologically annotated benchmarking cohort might be of great benefit for ongoing algorithm development.
Objectives: Diagnostic accuracy of artificial intelligence (AI) pneumothorax (PTX) detection in chest radiographs (CXR) is limited by the noisy annotation quality of public training data and confounding thoracic tubes (TT). We hypothesize that in-image annotations of the dehiscent visceral pleura for algorithm training boosts algorithm’s performance and suppresses confounders. Methods: Our single-center evaluation cohort of 3062 supine CXRs includes 760 PTX-positive cases with radiological annotations of PTX size and inserted TTs. Three step-by-step improved algorithms (differing in algorithm architecture, training data from public datasets/clinical sites, and in-image annotations included in algorithm training) were characterized by area under the receiver operating characteristics (AUROC) in detailed subgroup analyses and referenced to the well-established “CheXNet” algorithm. Results: Performances of established algorithms exclusively trained on publicly available data without in-image annotations are limited to AUROCs of 0.778 and strongly biased towards TTs that can completely eliminate algorithm’s discriminative power in individual subgroups. Contrarily, our final “algorithm 2” which was trained on a lower number of images but additionally with in-image annotations of the dehiscent pleura achieved an overall AUROC of 0.877 for unilateral PTX detection with a significantly reduced TT-related confounding bias. Conclusions: We demonstrated strong limitations of an established PTX-detecting AI algorithm that can be significantly reduced by designing an AI system capable of learning to both classify and localize PTX. Our results are aimed at drawing attention to the necessity of high-quality in-image localization in training data to reduce the risks of unintentionally biasing the training process of pathology-detecting AI algorithms. Key Points: • Established pneumothorax-detecting artificial intelligence algorithms trained on public training data are strongly limited and biased by confounding thoracic tubes.• We used high-quality in-image annotated training data to effectively boost algorithm performance and suppress the impact of confounding thoracic tubes.• Based on our results, we hypothesize that even hidden confounders might be effectively addressed by in-image annotations of pathology-related image features.
Objectives: Chest radiographs (CXRs) are commonly performed in emergency units (EUs), but the interpretation requires radiology experience. We developed an artificial intelligence (AI) system (precommercial) that aims to mimic board-certified radiologists' (BCRs') performance and can therefore support non–radiology residents (NRRs) in clinical settings lacking 24/7 radiology coverage. We validated by quantifying the clinical value of our AI system for radiology residents (RRs) and EU-experienced NRRs in a clinically representative EU setting. Materials and Methods: A total of 563 EU CXRs were retrospectively assessed by 3 BCRs, 3 RRs, and 3 EU-experienced NRRs. Suspected pathologies (pleural effusion, pneumothorax, consolidations suspicious for pneumonia, lung lesions) were reported on a 5-step confidence scale (sum of 20,268 reported pathology suspicions [563 images × 9 readers × 4 pathologies]) separately by every involved reader. Board-certified radiologists' confidence scores were converted into 4 binary reference standards (RFSs) of different sensitivities. The RRs' and NRRs' performances were statistically compared with our AI system (trained on nonpublic data from different clinical sites) based on receiver operating characteristics (ROCs) and operating point metrics approximated to the maximum sum of sensitivity and specificity (Youden statistics). Results: The NRRs lose diagnostic accuracy to RRs with increasingly sensitive BCRs' RFSs for all considered pathologies. Based on our external validation data set, the AI system/NRRs' consensus mimicked the most sensitive BCRs' RFSs with areas under ROC of 0.940/0.837 (pneumothorax), 0.953/0.823 (pleural effusion), and 0.883/0.747 (lung lesions), which were comparable to experienced RRs and significantly overcomes EU-experienced NRRs' diagnostic performance. For consolidation detection, the AI system performed on the NRRs' consensus level (and overcomes each individual NRR) with an area under ROC of 0.847 referenced to the BCRs' most sensitive RFS. Conclusions: Our AI system matched RRs' performance, meanwhile significantly outperformed NRRs' diagnostic accuracy for most of considered CXR pathologies (pneumothorax, pleural effusion, and lung lesions) and therefore might serve as clinical decision support for NRRs.
1 June 2021 in Quantitative Imaging in Medicine and Surgery