Shu Cai

Dr. Shu Cai


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2023 in ACS Nano
Verified
Journal Article
Closed access
YZYou Zuo
You Zuo
TMTengfei Meng
Tengfei Meng
HTHao Tian
Hao Tian
LLLei Ling
Lei Ling
HZHuanlin Zhang
Huanlin Zhang
SCShu Cai
Shu Cai


2 March 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
HZHuan Zhao
Huan Zhao
SCShu Cai
Shu Cai
ZDZetao Ding
Zetao Ding
MZMing Zhang
Ming Zhang
YLYan Li
Yan Li
GXGuohua Xu
Guohua Xu
A simple method has been proposed for the preparation of magnesium phosphate conversion coating on a magnesium alloy (AZ31) to achieve protection against fast degradation in an implant environment.

1 October 2018 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
SJSong Jiang
Song Jiang
SCShu Cai
Shu Cai
FZFeiyang Zhang
Feiyang Zhang
PXPeng Xu
Peng Xu
RLRui Ling
Rui Ling
GXGuohua Xu
Guohua Xu

4 March 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
YLYan Li
Yan Li
SCShu Cai
Shu Cai
GXGuohua Xu
Guohua Xu
SSSibo Shen
Sibo Shen
MZMin Zhang
Min Zhang
XSXiaohong Sun
Xiaohong Sun
In order to decrease the degradation rate and improve the bioactivity of a magnesium alloy, a phytic acid and mesoporous 45S5 bioglass composite coating (PMBC) has been synthesized on the AZ31 magnesium alloy by a two-step method. The phase, surface morphology and structure of the composite coatings were characterized by X-ray diffraction, scanning electron microscopy and Fourier transform infrared spectroscopy. The composite coating consisting of an interior layer of mesoporous 45S5 bioglass and an outer layer of phytic acid/magnesium phytic acid was dense, crack-free and had no remarkable interface between the inner and outer coating. The bonding strength of the composite coating to the magnesium alloy substrate was 15.2 ± 1.5 MPa. The immersion test in simulated body fluid (SBF) showed that the composite coating could provide obvious protection for the substrate and greatly decreased the degradation rate to 0.62 mg per cm2 per day from the uncoated sample of 2.93 mg per cm2 per day on the sixteenth day. And the outer coating of phytic acid could induce the formation of apatite, suggesting good bioactivity of the coated magnesium alloy.

1 February 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
YLYishu Lin
Yishu Lin
SCShu Cai
Shu Cai
SJSong Jiang
Song Jiang
DXDongli Xie
Dongli Xie
RLRui Ling
Rui Ling
GXGuohua Xu
Guohua Xu