Wesley Baker

Dr. Wesley Baker

The Children's Hospital of Philadelphia, Philadelphia, USA
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2010 in Reports on Progress in Physics
Verified
Journal Article
Closed access
Turgut DurduranTurgut Durduran
Turgut Durduran
RCR Choe
R Choe
Wesley BakerWesley Baker
Wesley Baker
AYA G Yodh
A G Yodh
This review describes the diffusion model for light transport in tissues and the medical applications of diffuse light. Diffuse optics is particularly useful for measurement of tissue hemodynamics, wherein quantitative assessment of oxy- and deoxy-hemoglobin concentrations and blood flow are desired. The theoretical basis for near-infrared or diffuse optical spectroscopy (NIRS or DOS, respectively) is developed, and the basic elements of diffuse optical tomography (DOT) are outlined. We also discuss diffuse correlation spectroscopy (DCS), a technique whereby temporal correlation functions of diffusing light are transported through tissue and are used to measure blood flow. Essential instrumentation is described, and representative brain and breast functional imaging and monitoring results illustrate the workings of these new tissue diagnostics.

28 October 2014 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Wesley BakerWesley Baker
Wesley Baker
APAshwin B. Parthasarathy
Ashwin B. Parthasarathy
DBDavid R Busch
David R Busch
Rickson C. MesquitaRickson C. Mesquita
Rickson C. Mesquita
JGJoel H. Greenberg
Joel H. Greenberg
AYA. G. Yodh
A. G. Yodh
We develop and validate a Modified Beer-Lambert law for blood flow based on diffuse correlation spectroscopy (DCS) measurements. The new formulation enables blood flow monitoring from temporal intensity autocorrelation function data taken at single or multiple delay-times. Consequentially, the speed of the optical blood flow measurement can be substantially increased. The scheme facilitates blood flow monitoring of highly scattering tissues in geometries wherein light propagation is diffusive or non-diffusive, and it is particularly well-suited for utilization with pressure measurement paradigms that employ differential flow signals to reduce contributions of superficial tissues.

30 August 2022 in Neurophotonics
Verified
Journal Article
Open access
PDF file
Hasan AyazHasan Ayaz
Hasan Ayaz
Wesley BakerWesley Baker
Wesley Baker
GBGiles Blaney
Giles Blaney
DBDavid A. Boas
David A. Boas
Heather BortfeldHeather Bortfeld
Heather Bortfeld
WZWenjun Zhou
Wenjun Zhou
We have come a long way since Jöbsis first demonstrated that noninvasive cerebral monitoring was possible in humans within the near-infrared light window (approximately 700 to 1000 nm) in the late 1970s.1 What started as a tool to quantify blood oxygenation in the brain has exploded into a whole field of study that aims to exploit this window to reveal a battery of information related to human brain physiology, including brain metabolism, blood flow, autoregulation, perfusion pressure, water concentration, light scattering, exogenous contrast agents, and more. In this text, we use the term “diffuse optics” to broadly describe any technique that employs a near-infrared light source and a photodetector to capture multiply scattered photons in the diffusion limit (i.e., in the limit wherein the absorption coefficient, μa, is much less than the reduced scattering coefficient, μs′, and the source-detector separation is much greater than the photon mean free path). The term “diffuse” has historical connotations in the field and reflects how near-infrared photons propagate through biological tissue. However, it should be noted that this term is in no way associated with how the field/community is organized or conducts its science. On the contrary, the breadth and depth of the progress made in the field over the past decade could only be accomplished by a cohesive, focused, and tight-knit community of researchers!

3 February 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
DWDetian Wang
Detian Wang
APAshwin B. Parthasarathy
Ashwin B. Parthasarathy
Wesley BakerWesley Baker
Wesley Baker
KGKimberly Gannon
Kimberly Gannon
VKVenki Kavuri
Venki Kavuri
AYArjun G. Yodh
Arjun G. Yodh
We introduce, validate and demonstrate a new software correlator for high-speed measurement of blood flow in deep tissues based on diffuse correlation spectroscopy (DCS). The software correlator scheme employs standard PC-based data acquisition boards to measure temporal intensity autocorrelation functions continuously at 50 – 100 Hz, the fastest blood flow measurements reported with DCS to date. The data streams, obtained in vivo for typical source-detector separations of 2.5 cm, easily resolve pulsatile heart-beat fluctuations in blood flow which were previously considered to be noise. We employ the device to separate tissue blood flow from tissue absorption/scattering dynamics and thereby show that the origin of the pulsatile DCS signal is primarily flow, and we monitor cerebral autoregulation dynamics in healthy volunteers more accurately than with traditional instrumentation as a result of increased data acquisition rates. Finally, we characterize measurement signal-to-noise ratio and identify count rate and averaging parameters needed for optimal performance.

14 May 2019 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Closed access
PDF file
Wesley BakerWesley Baker
Wesley Baker
RBRamani Balu
Ramani Balu
LHLian He
Lian He
VKVenkaiah C Kavuri
Venkaiah C Kavuri
DBDavid R Busch
David R Busch
WKW Andrew Kofke
W Andrew Kofke
Rapid detection of ischemic conditions at the bedside can improve treatment of acute brain injury. In this observational study of 11 critically ill brain-injured adults, we employed a monitoring approach that interleaves time-resolved near-infrared spectroscopy (TR-NIRS) measurements of cerebral oxygen saturation and oxygen extraction fraction (OEF) with diffuse correlation spectroscopy (DCS) measurement of cerebral blood flow (CBF). Using this approach, we demonstrate the clinical promise of non-invasive, continuous optical monitoring of changes in CBF and cerebral metabolic rate of oxygen (CMRO2). In addition, the optical CBF and CMRO2 measures were compared to invasive brain tissue oxygen tension (PbtO2), thermal diffusion flowmetry CBF, and cerebral microdialysis measures obtained concurrently. The optical CBF and CMRO2 information successfully distinguished between ischemic, hypermetabolic, and hyperemic conditions that arose spontaneously during patient care. Moreover, CBF monitoring during pressor-induced changes of mean arterial blood pressure enabled assessment of cerebral autoregulation. In total, the findings suggest that this hybrid non-invasive neurometabolic optical monitor (NNOM) can facilitate clinical detection of adverse physiological changes in brain injured patients that are otherwise difficult to measure with conventional bedside monitoring techniques.

1 July 2015 in Neurophotonics
Verified
Journal Article
Open access
PDF file
Wesley BakerWesley Baker
Wesley Baker
APAshwin B. Parthasarathy
Ashwin B. Parthasarathy
Tiffany S. KoTiffany S. Ko
Tiffany S. Ko
DBDavid R Busch
David R Busch
KAKenneth Abramson
Kenneth Abramson
AYArjun Yodh
Arjun Yodh
We introduce and validate a pressure measurement paradigm that reduces extracerebral contamination from superficial tissues in optical monitoring of cerebral blood flow with diffuse correlation spectroscopy (DCS). The scheme determines subject-specific contributions of extracerebral and cerebral tissues to the DCS signal by utilizing probe pressure modulation to induce variations in extracerebral blood flow. For analysis, the head is modeled as a two-layer medium and is probed with long and short source-detector separations. Then a combination of pressure modulation and a modified Beer-Lambert law for flow enables experimenters to linearly relate differential DCS signals to cerebral and extracerebral blood flow variation without a priori anatomical information. We demonstrate the algorithm’s ability to isolate cerebral blood flow during a finger-tapping task and during graded scalp ischemia in healthy adults. Finally, we adapt the pressure modulation algorithm to ameliorate extracerebral contamination in monitoring of cerebral blood oxygenation and blood volume by near-infrared spectroscopy.