Seungho Baek

Mr. Seungho Baek


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
SBSeungho Baek
Seungho Baek
CPChanyong Park
Chanyong Park
JJJaehyung Jeon
Jaehyung Jeon
Sungsu ParkSungsu Park
Sungsu Park
Paper-based microfluidic analysis devices (μPADs) have attracted attention as a cost-effective platform for point-of-care testing (POCT), food safety, and environmental monitoring. Recently, three-dimensional (3D)-μPADs have been developed to improve the performance of μPADs. For accurate diagnosis of diseases, however, 3D-μPADs need to be developed to simultaneously detect multiple biomarkers. Here, we report a 3D-μPADs platform for the detection of multiple biomarkers that can be analyzed and diagnosed with a smartphone. The 3D-μPADs were fabricated using a 3D digital light processing printer and consisted of a sample reservoir (300 µL) connected to 24 detection zones (of 4 mm in diameter) through eight microchannels (of 2 mm in width). With the smartphone application, eight different biomarkers related to various diseases were detectable in concentrations ranging from normal to abnormal conditions: glucose (0–20 mmol/L), cholesterol (0–10 mmol/L), albumin (0–7 g/dL), alkaline phosphatase (0–800 U/L), creatinine (0–500 µmol/L), aspartate aminotransferase (0–800 U/L), alanine aminotransferase (0–1000 U/L), and urea nitrogen (0–7.2 mmol/L). These results suggest that 3D-µPADs can be used as a POCT platform for simultaneous detection of multiple biomarkers.

1 May 2020 in medRxiv
Verified
Preprint
Open access
PDF file
JLJinyeop Lee
Jinyeop Lee
CBCheolwoo Bong
Cheolwoo Bong
PBPan Kee Bae
Pan Kee Bae
AAAbdurhaman Teyib Abafogi
Abdurhaman Teyib Abafogi
SBSeungho Baek
Seungho Baek
Sungsu ParkSungsu Park
Sungsu Park
Face masks are one of the currently available options for preventing the transmission of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which has caused the 2019 pandemic. However, with the increasing demand for protection, face masks are becoming limited in stock, and the concerned individuals and healthcare workers from many countries are now facing the issue of the reuse of potentially contaminated masks. Although various technologies already exist for the sterilization of medical equipment, most of them are not applicable for eliminating virus from face masks. Thus, there is an urgent need to develop a fast and easy method of disinfecting contaminated face masks. In this study, using a human coronavirus (HCoV-229E) as a surrogate for SARS-CoV-2 contamination on face masks, we show that the virus loses its infectivity to a human cell line (MRC-5) when exposed for a short period of time (1 min) to ozone gas produced by a dielectric barrier discharge plasma generator. Scanning electron microscopy and particulate filtration efficiency (PFE) tests revealed that there was no structural or functional deterioration observed in the face masks even after they underwent excessive exposure to ozone (five 1-minute exposures). Interestingly, for face masks exposed to ozone gas for 5 min, the amplification of HCoV-229E RNA by reverse transcription polymerase chain reaction suggested a loss of infectivity under the effect of ozone, primarily owing to the damage caused to viral envelopes or envelope proteins. Ozone gas is a strong oxidizing agent with the ability to kill viruses on hard-to-reach surfaces, including the fabric structure of face masks. These results suggest that it may be possible to rapidly disinfect contaminated face masks using a plasma generator in a well-ventilated place.