Nikolaos Gkantidis

Prof. Dr. Nikolaos Gkantidis

University of Bern, Bern, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2018 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
APAikaterini Papadimitriou
Aikaterini Papadimitriou
SMSophia Mousoulea
Sophia Mousoulea
Nikolaos GkantidisNikolaos Gkantidis
Nikolaos Gkantidis
DKDimitrios Kloukos
Dimitrios Kloukos
Aim was to systematically search the literature and assess the available evidence regarding the clinical effectiveness of the Invisalign® system. Electronic database searches of published and unpublished literature were performed. The reference lists of all eligible articles were examined for additional studies. Reporting of this review was based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Three RCTs, 8 prospective, and 11 retrospective studies were included. In general, the level of evidence was moderate and the risk of bias ranged from low to high, given the low risk of bias in included RCTs and the moderate (n = 13) or high (n = 6) risk of the other studies. The lack of standardized protocols and the high amount of clinical and methodological heterogeneity across the studies precluded a valid interpretation of the actual results through pooled estimates. However, there was substantial consistency among studies that the Invisalign® system is a viable alternative to conventional orthodontic therapy in the correction of mild to moderate malocclusions in non-growing patients that do not require extraction. Moreover, Invisalign® aligners can predictably level, tip, and derotate teeth (except for cuspids and premolars). On the other hand, limited efficacy was identified in arch expansion through bodily tooth movement, extraction space closure, corrections of occlusal contacts, and larger antero-posterior and vertical discrepancies. Although this review included a considerable number of studies, no clear clinical recommendations can be made, based on solid scientific evidence, apart from non-extraction treatment of mild to moderate malocclusions in non-growing patients. Results should be interpreted with caution due to the high heterogeneity.

1 May 2010 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
Nikolaos GkantidisNikolaos Gkantidis
Nikolaos Gkantidis
PCP. Christou
P. Christou
NTN. Topouzelis
N. Topouzelis

24 January 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JWJonas Winkler
Jonas Winkler
Nikolaos GkantidisNikolaos Gkantidis
Nikolaos Gkantidis
Intraoral three-dimensional imaging has gained great interest in dentistry as a mean to generate risk-free imprints of the oral cavity. Accurate intraoral models facilitate proper diagnosis, growth assessment, outcome evaluation, and 3D printing applications. Here, in an actual clinical setup on 12 subjects, we evaluate the trueness and precision of two widely used intraoral scanners (TRIOS 3, 3Shape and CS 3600, Carestream), using an industrial scanner (Artec Space Spider) as a reference. Surface based matching was implemented using the iterative closest point algorithm (ICP). Trueness of the intraoral scans was analyzed by measuring their distance from the reference scan, in the upper buccal front area. Precision was tested through the distance of repeated scans regarding the whole dental arch, following superimpositions in the buccal front and in the whole dental arch area. TRIOS 3 displayed slightly higher precision (approximately 10 μm) compared to CS 3600, only after superimposition on the whole dental arch (p < 0.05). Both intraoral scanners showed good performance and comparable trueness (median: 0.0154 mm; p> 0.05). However, in individual cases and in various, not spatially defined areas, higher imprecision was evident. Thus, the intraoral scanners’ appropriateness for highly demanding, spatially extended clinical applications remains questionable.

1 October 2014 in Journal of Dentistry
Verified
Journal Article
Closed access
Nikolaos GkantidisNikolaos Gkantidis
Nikolaos Gkantidis
IMIlias Mistakidis
Ilias Mistakidis
TKThaleia Kouskoura
Thaleia Kouskoura
NPNikolaos Pandis
Nikolaos Pandis

1 January 2014 in The Angle Orthodontist
Verified
Journal Article
Closed access
GTGeorge Tsomos
George Tsomos
BLBjörn Ludwig
Björn Ludwig
JGJohannes Grossen
Johannes Grossen
PPPawel Pazera
Pawel Pazera
Nikolaos GkantidisNikolaos Gkantidis
Nikolaos Gkantidis
Objective: To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. Materials and Methods: Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. Results: There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55–318 days) the actual wear time was 9.0 h/d (range, 0.0–16.0 h/d) and did not differ between distinct prescriptions ( P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0–89.3%) for the 14 h/d and 112.5% (range, 0.0–200.0%) for the 8 h/d prescription wear ( P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = −0.61, P = .00; 8 h/d prescription: n = 24, rho = −0.73, P = .00), while sex did not exert a significant influence on compliance ( P = .58). Conclusions: Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.

23 February 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Nikolaos GkantidisNikolaos Gkantidis
Nikolaos Gkantidis
MSMichael Schauseil
Michael Schauseil
PPPawel Pazera
Pawel Pazera
BZBerna Zorkun
Berna Zorkun
CKChristos Katsaros
Christos Katsaros
BLBjörn Ludwig
Björn Ludwig
To test the applicability, accuracy, precision, and reproducibility of various 3D superimposition techniques for radiographic data, transformed to triangulated surface data. Five superimposition techniques (3P: three-point registration; AC: anterior cranial base; AC + F: anterior cranial base + foramen magnum; BZ: both zygomatic arches; 1Z: one zygomatic arch) were tested using eight pairs of pre-existing CT data (pre- and post-treatment). These were obtained from non-growing orthodontic patients treated with rapid maxillary expansion. All datasets were superimposed by three operators independently, who repeated the whole procedure one month later. Accuracy was assessed by the distance (D) between superimposed datasets on three form-stable anatomical areas, located on the anterior cranial base and the foramen magnum. Precision and reproducibility were assessed using the distances between models at four specific landmarks. Non parametric multivariate models and Bland-Altman difference plots were used for analyses. There was no difference among operators or between time points on the accuracy of each superimposition technique (p>0.05). The AC + F technique was the most accurate (D<0.17 mm), as expected, followed by AC and BZ superimpositions that presented similar level of accuracy (D<0.5 mm). 3P and 1Z were the least accurate superimpositions (0.79<D<1.76 mm, p0.05), the detected structural changes differed significantly between different techniques (p<0.05). Bland-Altman difference plots showed that BZ superimposition was comparable to AC, though it presented slightly higher random error. Superimposition of 3D datasets using surface models created from voxel data can provide accurate, precise, and reproducible results, offering also high efficiency and increased post-processing capabilities. In the present study population, the BZ superimposition was comparable to AC, with the added advantage of being applicable to scans with a smaller field of view.