Juan Peris Vicente

Dr. Juan Peris Vicente


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2009 in Analytical Chemistry
Verified
Journal Article
Closed access
JVJuan Peris Vicente
Juan Peris Vicente
UBU. Baumer
U. Baumer
HSH. Stege
H. Stege
KLK. Lutzenberger
K. Lutzenberger
JAJ. V. Gimeno Adelantado
J. V. Gimeno Adelantado

8 October 2018 in Journal of the Science of Food and Agriculture
Verified
Journal Article
Closed access
PDF file
JVJuan Peris Vicente
Juan Peris Vicente
JIJesús Javier Iborra‐Millet
Jesús Javier Iborra‐Millet
JAJaume Albiol‐Chiva
Jaume Albiol‐Chiva
SCSamuel Carda-Broch
Samuel Carda-Broch
JEJosep Esteve‐Romero
Josep Esteve‐Romero

7 November 2011 in The Analyst
Verified
Journal Article
Closed access
PDF file
BBBeatriz Beltrán-Martinavarro
Beatriz Beltrán-Martinavarro
JVJuan Peris Vicente
Juan Peris Vicente
SMSergio Marco-Peiró
Sergio Marco-Peiró
JEJosep Esteve-Romero
Josep Esteve-Romero
MRMaria Rambla-Alegre
Maria Rambla-Alegre
SCSamuel Carda-Broch
Samuel Carda-Broch
Melamine is a nitrogen-rich industrial chemical which is occasionally used to increase the apparent protein content of different products destined for human and animal consumption. In this work, a liquid chromatographic procedure that uses micellar mobile phases of sodium dodecyl sulfate (SDS) buffered at pH 3, a C18 column and UV detection is reported for the determination of melamine in dietetic supplements. Samples were reconstituted with a SDS solution and were directly injected, thus avoiding long extraction and experimental procedures. Melamine was eluted in less than 10 min with no interference by other compounds of the matrices. The optimum mobile phase composition was taken by a chemometrical approach that considers the retention factor, efficiency and peak shape. Validation was performed following the indications of the European Commission (Decision 2002/657/EC). The following parameters were considered: linearity (0.02–100 μg mL−1; R2 = 0.9996), intra- and inter-day precisions (<12.4%), accuracy (90.0–101.3%), and robustness (less than 9.8% and 5.1%, for retention time and peak area, respectively). The limits of detection and quantification were 9 and 20 ng mL−1, respectively. Recoveries for several spiked samples were in the 85.8–114.3% range. These results indicate that the proposed methodology is useful for routine analysis of control quality of infant formula and adult dietetic supplements.

1 February 2018 in Journal of Chromatography B
Verified
Journal Article
Closed access
JAJaume Albiol-Chiva
Jaume Albiol-Chiva
JEJosep Esteve-Romero
Josep Esteve-Romero
JVJuan Peris Vicente
Juan Peris Vicente

11 December 2018 in Antibiotics
Verified
Journal Article
Open access
PDF file
PMPOOJA MISHRA
POOJA MISHRA
JAJaume Albiol-Chiva
Jaume Albiol-Chiva
DBDevasish Bose
Devasish Bose
ADAbhilasha Durgbanshi
Abhilasha Durgbanshi
JVJuan Peris Vicente
Juan Peris Vicente
Josep Esteve-RomeroJosep Esteve-Romero
Josep Esteve-Romero
Isoniazid is a drug that is widely used against tuberculosis. However, it shows high interpatient variability in metabolism kinetics and clinical effect, which complicates the prescription of the medication and jeopardizes the success of the therapy. Therefore, in a specific patient, the pharmacokinetics of the drug must be elucidated to decide the proper dosage and intake frequency to make the drug suitable for therapeutic drug monitoring. This can be performed by the quantification of the drug in urine as this process is non-invasive and allows the effects of long-time exposure to be inferred. The paper describes the development of a micellar liquid chromatographic method to quantify isoniazid in urine samples. Extraction steps were avoided, making the procedure easy to handle and reducing the waste of toxic organic solvents. Isoniazid was eluted in less than 5 min without interference from other compounds of the urine using a mobile phase containing 0.15 SDS–12.5% 1-propanol (v/v)–Na2HPO4 0.01 M buffered at pH 7, running at 1 mL/min under isocratic mode through a C18 column with the detection wavelength at 265 nm. The method was validated by following the requirements of the Guidelines on Bioanalytical Method Validation issued by the European Medicines Agency (EMA) in terms of selectivity, calibration curve (r2 = 0.9998 in the calibration range (0.03–10.0 μg/mL), limit of detection and quantification (10 and 30 ng/mL respectively), precision (<16.0%), accuracy (−0.9 to +8.5%), carry-over, matrix effect, and robustness. The developed method was applied to quantify isoniazid in urine samples of patients of an Indian hospital with good results. The method was found to be useful for routine analysis to check the amount of isoniazid in these patients and could be used in its therapeutic monitoring.

14 February 2020 in Antibiotics
Verified
Journal Article
Open access
PDF file
RPRajendra Prasad Pawar
Rajendra Prasad Pawar
PMPooja Mishra
Pooja Mishra
ADAbhilasha Durgbanshi
Abhilasha Durgbanshi
DBDevasish Bose
Devasish Bose
JAJaume Albiol-Chiva
Jaume Albiol-Chiva
Josep Esteve-RomeroJosep Esteve-Romero
Josep Esteve-Romero
Mebendazole is an anthelmintic drug used in cattle production. However, residues may occur in produced food and in excretions, jeopardizing population health. A method based on micellar liquid chromatography (MLC) was developed to determine mebendazole in dairy products (milk, cheese, butter, and curd) and nitrogenous waste (urine and dung) from bovine animals. Sample treatment was expedited to simple dilution or solid-to-liquid extraction, followed by filtration and direct injection of the obtained solution. The analyte was resolved from matrix compounds in less than 8 min, using a C18 column and a mobile phase made up of 0.15 M sodium dodecyl sulfate (SDS)–6% 1-pentanol phosphate buffered at pH 7, and running at 1 mL/min under isocratic mode. Detection was performed by absorbance at 292 nm. The procedure was validated according to the guidelines of the EU Commission Decision 2002/657/EC in terms of: specificity, method calibration range (from the limit of quantification to 25–50 ppm), sensitivity (limit of detection 0.1–0.2 ppm; limit of quantification, 0.3–0.6 ppm), trueness (92.5–102.3%), precision (<7.5%, expressed at RSD), robustness, and stability. The method is reliable, sensitive, easy-to-handle, eco-friendly, safe, inexpensive, and provides a high sample-throughput. Therefore, it is useful for routine analysis as a screening or quantification method in a laboratory for drug-residue control.