Ling Wang

Prof. Ling Wang

State Key Laboratory for Manufacturing System Engineering, Xi’an Jiaotong University

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Seyed Ataollah NaghaviSeyed Ataollah Naghavi
Seyed Ataollah Naghavi
MTMaryam Tamaddon
Maryam Tamaddon
AMArsalan Marghoub
Arsalan Marghoub
KWKatherine Wang
Katherine Wang
BBBehzad Bahrami Babamiri
Behzad Bahrami Babamiri
Chaozong LiuChaozong Liu
Chaozong Liu
Additive manufacturing has been used to develop a variety of scaffold designs for clinical and industrial applications. Mechanical properties (i.e., compression, tension, bending, and torsion response) of these scaffolds are significantly important for load-bearing orthopaedic implants. In this study, we designed and additively manufactured porous metallic biomaterials based on two different types of triply periodic minimal surface structures (i.e., gyroid and diamond) that mimic the mechanical properties of bone, such as porosity, stiffness, and strength. Physical and mechanical properties, including compressive, tensile, bending, and torsional stiffness and strength of the developed scaffolds, were then characterised experimentally and numerically using finite element method. Sheet thickness was constant at 300 μm, and the unit cell size was varied to generate different pore sizes and porosities. Gyroid scaffolds had a pore size in the range of 600–1200 μm and a porosity in the range of 54–72%, respectively. Corresponding values for the diamond were 900–1500 μm and 56–70%. Both structure types were validated experimentally, and a wide range of mechanical properties (including stiffness and yield strength) were predicted using the finite element method. The stiffness and strength of both structures are comparable to that of cortical bone, hence reducing the risks of scaffold failure. The results demonstrate that the developed scaffolds mimic the physical and mechanical properties of cortical bone and can be suitable for bone replacement and orthopaedic implants. However, an optimal design should be chosen based on specific performance requirements.
1

1 September 2021 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
JZJibao Zheng
Jibao Zheng
HZHuiyu Zhao
Huiyu Zhao
EDEnchun Dong
Enchun Dong
JKJianfeng Kang
Jianfeng Kang
CLChaozong Liu
Chaozong Liu
LWLing Wang
Ling Wang

13 April 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
BYBin Yu
Bin Yu
HLHekai Li
Hekai Li
ZZZhaowenbin Zhang
Zhaowenbin Zhang
PCPeier Chen
Peier Chen
LWLing Wang
Ling Wang
COCaiwen Ou
Caiwen Ou
Extracellular vesicles have shown good potential in disease treatments including ischemic injury such as myocardial infarction. However, the efficient production of highly active extracellular vesicles is one of the critical limitations for their clinical applications. Here, we demonstrate a biomaterial-based approach to prepare high amounts of extracellular vesicles with high bioactivity from endothelial progenitor cells (EPCs) by stimulation with silicate ions derived from bioactive silicate ceramics. We further show that hydrogel microspheres containing engineered extracellular vesicles are highly effective in the treatment of myocardial infarction in male mice by significantly enhancing angiogenesis. This therapeutic effect is attributed to significantly enhanced revascularization by the high content of miR-126a-3p and angiogenic factors such as VEGF and SDF-1, CXCR4 and eNOS in engineered extracellular vesicles, which not only activate endothelial cells but also recruit EPCs from the circulatory system.

29 October 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Seyed Ataollah NaghaviSeyed Ataollah Naghavi
Seyed Ataollah Naghavi
CLChurun Lin
Churun Lin
CSChangning Sun
Changning Sun
MTMaryam Tamaddon
Maryam Tamaddon
MBMariam Basiouny
Mariam Basiouny
Chaozong LiuChaozong Liu
Chaozong Liu
Stress shielding secondary to bone resorption is one of the main causes of aseptic loosening, which limits the lifespan of the hip prostheses and increases the rates of revision surgery. This study proposes a low stiffness polyether–ether–ketone (PEEK) hip prostheses, produced by fused deposition modelling to minimize the stress difference after the hip replacement. The stress shielding effect and the potential bone resorption of the PEEK implant was investigated through both experimental tests and FE simulation. A generic Ti6Al4V implant was incorporated in this study to allow fair comparison as control group. Attributed to the low stiffness, the proposed PEEK implant showed a more natural stress distribution, less stress shielding (by 104%), and loss in bone mass (by 72%) compared with the Ti6Al4V implant. The stiffness of the Ti6Al4V and the PEEK implant were measured through compression tests to be 2.76 kN/mm and 0.276 kN/mm. The factor of safety for the PEEK implant in both static and dynamic loading scenarios were obtained through simulation. Most of the regions in the PEEK implant were tested to be safe (FoS larger than 1) in terms of representing daily activities (2300 N), while the medial neck and distal restriction point of the implant attracts large von Mises stress 82 MPa and 76 MPa, respectively, and, thus, may possibly fail during intensive activities by yield and fatigue. Overall, considering the reduction in stress shielding and bone resorption in cortical bone, PEEK could be a promising material for the patient–specific femoral implants.
1

5 May 2018 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
JKJianfeng Kang
Jianfeng Kang
LWLing Wang
Ling Wang
CYChuncheng Yang
Chuncheng Yang
LWLei Wang
Lei Wang
CYCao Yi
Cao Yi
DLDichen Li
Dichen Li
A tumour resection normally involves a large tissue resection and bone replacement. Polyether ether ketone (PEEK) has become a suitable candidate for use in various prostheses owing to its lightness in weight, modulus close to that of natural bone, and good biocompatibility, among other factors. This study proposes a new design method for a rib prosthesis using the centroid trajectory of the natural replaced rib, where the strength can be adjusted by monitoring the cross-sectional area, shape, and properties. A custom-designed rib prosthesis was manufactured using fused deposition modelling (FDM) manufacturing technology, and the mechanical behaviour was found to be close to that of a natural rib. A finite element analysis of the designed rib was carried out under similar loading conditions to those used in mechanical testing. The results indicate that the centroid trajectory derived from a natural rib diaphysis can provide reliable guidance for the design of a rib prosthesis. Such methodology not only offers considerable design freedom in terms of shape and required strength, but also benefits the quality of the surface finishing for samples manufactured using the FDM technique. FDM-printed PEEK rib prostheses have been successfully implanted, and good clinical performances have been achieved.

18 November 2021 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
XWXiaoqi Wu
Xiaoqi Wu
WGWeihong Guo
Weihong Guo
LWLing Wang
Ling Wang
YXYichao Xu
Yichao Xu
ZWZihan Wang
Zihan Wang
HWHuang Wenhua
Huang Wenhua