The use of networks for communication between electronic control units has increased in car industry over the last two decades. Several types of networks were developed for this purpose. In this study, Ethernet at gigabit speed is tested as a network for such system. The use of Ethernet helps integrating real-time control functions and non-real-time entertainment functions. Two main scenarios were simulated using OPNET. The fist one simulates pure control networks on board of a moving vehicle. The second scenario is the same as the first one with an added video load to simulate on-board entertainment. Both simulations were successful, as the end-to-end delays were below the maximum round-trip delays required by the system
1 November 2006 in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
This paper introduces the idea of using the stigmergic approach to solve traffic problems in congested urban areas and focuses on the communications aspect of the problem. V2I and I2V are based on IEEE 802.11 standard. The urban area is equipped with access points that are wired to a central node. The number of packets lost is investigated at different vehicle speeds as well as different I2V broadcast rates. The best broadcast rate is found in order to reduce the packets lost irrespective of vehicle speed
1 November 2006 in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
Automotive industry is in continuous evolution. Luxury as well as comfort is important. Safety measures are the most important in designing a moving vehicle. Safety can be studied from a mechanical point of view as well as from an electrical point of view. This paper presents a simulation study for fault-tolerant sensor networks for cars' on-board control. On-board communication and control networks are built using gigabit Ethernet. OPNET simulations showed feasibility and success of the proposed model with mixed traffic for real-time and non-real-time applications
This paper investigates the effect of failures on the productivity of fault-tolerant networked control systems under varying loads. Higher speeds of operation are sometimes used to increase production and compensate for down time due to component failures. Improved Markov models are developed and used to calculate system probabilities. When these probabilities are combined with the maximum speed of operation in each system state, the average speed of operation is obtained. If machines cannot be run at maximum speed all the time, the Markov models are used again to find the best speed mix that would yield maximum output capacity
Field programmable gate arrays (FPGAs) are increasingly used in industry (e.g., biomedical, space, and automotive industries). FPGAs are subjected to single, as well as multiple event upsets (SEUs and MEUs), due to the continuous shrinking of transistor dimensions. These upsets inevitably decrease system lifetime. Fault-tolerant techniques are often used to mitigate these problems. In this research, penta and hexa modular redundancy, as well as dynamic partial reconfiguration (DPR), are used to increase system reliability. We show, depending on the relative rates of the SEUs and MEUs, that penta modular redundancy has a higher reliability than hexa modular redundancy, which is a counter-intuitive result in some cases since increasing redundancy is expected to increase reliability. Focusing on penta modular redundancy, an error detection and recovery mechanism (voter) is designed. This mechanism uses the internal configuration access port (ICAP) and its associated controller, as well as DPR to mitigate SEUs and MEUs. Then, it is implemented on Xilinx Vivado tools targeting the Kintex7 7k410tfbg676 device. Finally, we show how to render this design fault secure in the event that SEUs or MEUs affect the voter itself. This fault secure voter either produces the correct output or gives an indication that the output is incorrect.
This paper proposes a fault-tolerant flexible manufacturing system (FMS) that features a dual-level fault tolerance mechanism at both the workcell and system levels to enhance reliability. The workcell controller was implemented on a Field Programmable Gate Array (FPGA). Reconfigurable duplication was used as the first level of fault tolerance at the workcell level. It was shown how to detect and recover from FPGA faults such as Single Event Upsets (SEUs), hard faults, and Single Event Functional Interrupts (SEFIs). The prototype of the workcell controller was successfully implemented using two Zybo Z7-20 AMD boards and an Arduino DUE. Petri Nets were used to prove that controller reliability increased by 346% after 1440 operational hours. The second level of fault tolerance was at the FMS level; the Supervisor (SUP) took over the responsibilities of any malfunctioning workcell controller. Riverbed software was used to prove that the system successfully met the end-to-end delay requirements. Finally, Matlab showed that there is a further increase in performability.