Carlo Gonzato

Dr. Carlo Gonzato

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
NLNadja Leibl
Nadja Leibl
Karsten HauptKarsten Haupt
Karsten Haupt
CGCarlo Gonzato
Carlo Gonzato
LDLuminita Duma
Luminita Duma
The field of molecularly imprinted polymer (MIP)-based chemosensors has been experiencing constant growth for several decades. Since the beginning, their continuous development has been driven by the need for simple devices with optimum selectivity for the detection of various compounds in fields such as medical diagnosis, environmental and industrial monitoring, food and toxicological analysis, and, more recently, the detection of traces of explosives or their precursors. This review presents an overview of the main research efforts made so far for the development of MIP-based chemosensors, critically discusses the pros and cons, and gives perspectives for further developments in this field.

30 September 2021 in ACS Applied Polymer Materials
Verified
Journal Article
Closed access
EPErnesto Iii Paruli
Ernesto Iii Paruli
Olivier SopperaOlivier Soppera
Olivier Soppera
Karsten HauptKarsten Haupt
Karsten Haupt
CGCarlo Gonzato
Carlo Gonzato

1 October 2020 in Bioelectrochemistry
Verified
Journal Article
Closed access
NLNadja Leibl
Nadja Leibl
LDLuminita Duma
Luminita Duma
CGCarlo Gonzato
Carlo Gonzato
Karsten HauptKarsten Haupt
Karsten Haupt

20 July 2017 in Polymer Chemistry
Verified
Journal Article
Closed access
PDF file
MGMariano J. Garcia-Soto
Mariano J. Garcia-Soto
Karsten HauptKarsten Haupt
Karsten Haupt
CGCarlo Gonzato
Carlo Gonzato
A new prospect for the synthesis of molecularly imprinted polymers: photo-iniferter polymerization under visible light.

1 December 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
JYJyoti
Jyoti
CGCarlo Gonzato
Carlo Gonzato
TŻTeresa Żołek
Teresa Żołek
DMDorota Maciejewska
Dorota Maciejewska
Andrzej KutnerAndrzej Kutner
Andrzej Kutner
WKWlodzimierz Kutner
Wlodzimierz Kutner
Molecularly imprinted polymer (MIP) nanoparticles-based differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) chemosensors for antiplatelet drug substance, cilostazol (CIL), and its pharmacologically active primary metabolite, 3,4-dehydrocilostazol (dhCIL), selective determination in human plasma were devised, prepared, and tested. Molecular mechanics (MM), molecular dynamics (MD), and density functional theory (DFT) simulations provided the optimum structure and predicted the stability of the pre-polymerization complex of the CIL template with the chosen functional acrylic monomers. Moreover, they accounted for the MIP selectivity manifested by the molecularly imprinted cavity with the CIL molecule complex stability higher than that for each interference. On this basis, a fast and reliable method for determining both compounds was developed to meet an essential requirement concerning the personalized drug dosage adjustment. The limit of detection (LOD) at the signal-to-noise ratio of S/N = 3 in DPV and EIS determinations using the ferrocene redox probe in a "gate effect" mode was 93.5 (±2.2) and 86.5 (±4.6) nM CIL, respectively, and the linear dynamic concentration range extended from 134 nM to 2.58 μM in both techniques. The chemosensor was highly selective to common biological interferences, including cholesterol and glucose, and less selective to structurally similar dehydroaripiprazole. Advantageously, it responded to dhCIL, thus allowing for the determination of CIL and dhCIL together. The EIS chemosensor appeared slightly superior to the DPV chemosensor concerning its selectivity to interferences. The CIL DPV sorption data were fitted with Langmuir, Freundlich, and Langmuir-Freundlich isotherms. The determined sorption parameters indicated that the imprinted cavities were relatively homogeneous and efficiently interacted with the CIL molecule.

28 June 2022 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
QZQi Zhou
Qi Zhou
YSYui Sasaki
Yui Sasaki
KOKohei Ohshiro
Kohei Ohshiro
HFHaonan Fan
Haonan Fan
VMValentina Montagna
Valentina Montagna
Tsuyoshi MinamiTsuyoshi Minami
Tsuyoshi Minami
This study proposes a chemical sensing approach for the selective detection of tropane alkaloid drugs based on an extended-gate-type organic field-effect transistor (OFET) functionalized with a molecularly imprinted polymer (MIP). From the viewpoint of pharmaceutical chemistry, the development of versatile chemical sensors to determine the enantiomeric purity of over-the-counter (OTC) tropane drugs is important because of their side effects and different pharmacological activities depending on their chirality. To this end, we newly designed an OFET sensor with an MIP (MIP-OFET) as the recognition element for tropane drugs based on a high complementarity among a template (i.e., (S)-hyoscyamine) and functional monomers such as N-isopropylacrylamide and 2,2-dimethyl-4-pentenoic acid. Indeed, the MIP optimized by density functional theory (DFT) has succeeded in the sensitive and selective detection of (S)-hyoscyamine (as low as 1 μM) by the combination of the OFET with highly selective recognition sites in the MIP. The MIP-OFET was further applied to determine the enantiomeric excess (ee) of commercially available (S)-hyoscyamine, and the linearity changes in the threshold voltages of the OFET corresponded to the % ee values of (S)-hyoscyamine. Overall, the validation with tropane alkaloids revealed the potential of the MIP combined with OFET as a chemical sensor chip for OTC drugs in real-world scenarios.