Reimund Bayerlein

Dr. Reimund Bayerlein

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2018 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
JAJ. B. Albert
J. B. Albert
GAG. Anton
G. Anton
IBI. Badhrees
I. Badhrees
PBP. S. Barbeau
P. S. Barbeau
RBReimund Bayerlein
Reimund Bayerlein
ECEXO-200 Collaboration
EXO-200 Collaboration
Results from a search for neutrinoless double-beta decay (0νββ) of Xe136 are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to σ/E=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between 0νββ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level 0νββ half-life sensitivity after combining with the full data set acquired before the upgrade has increased twofold to 3.7×1025  yr. No statistically significant evidence for 0νββ is observed, leading to a lower limit on the 0νββ half-life of 1.8×1025  yr at the 90% confidence level.

1 August 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
SDS. Delaquis
S. Delaquis
MJM.J. Jewell
M.J. Jewell
IOIgor Ostrovskiy
Igor Ostrovskiy
MWM. Weber
M. Weber
TZT. Ziegler
T. Ziegler
OZO.YA. Zeldovich
O.YA. Zeldovich
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters—total energy and position—directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.

1 November 2017 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
DLD.S. Leonard
D.S. Leonard
DAD.J. Auty
D.J. Auty
TDT. Didberidze
T. Didberidze
RGR. Gornea
R. Gornea
PGP. Grinberg
P. Grinberg
TZT. Ziegler
T. Ziegler

10 April 2018 in Physical Review D
Verified
Journal Article
Open access
PDF file
JAJ Albert
J Albert
GAG Anton
G Anton
IBI Badhrees
I Badhrees
PBP Barbeau
P Barbeau
RBReimund Bayerlein
Reimund Bayerlein
TZT Ziegler
T Ziegler
A search for instability of nucleons bound in Xe136 nuclei is reported with 223 kg·yr exposure of Xe136 in the EXO-200 experiment. Lifetime limits of 3.3×1023 and 1.9×1023  yr are established for nucleon decay to Sb133 and Te133, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.

3 November 2017 in Physical Review D
Verified
Journal Article
Open access
PDF file
JAJ. B. Albert
J. B. Albert
GAG. Anton
G. Anton
IBI. Badhrees
I. Badhrees
PBP. S. Barbeau
P. S. Barbeau
RBReimund Bayerlein
Reimund Bayerlein
ECEXO-200 Collaboration
EXO-200 Collaboration
Searches for double beta decay of Xe134 were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of Xe136. Using an exposure of 29.6  kg·yr, the lower limits of T1/22νββ>8.7×1020  yr and T1/20νββ>1.1×1023  yr at 90% confidence level were derived, with corresponding half-life sensitivities of 1.2×1021  yr and 1.9×1023  yr. These limits exceed those in the literature for Xe134, improving by factors of nearly 105 and 2 for the two antineutrino and neutrinoless modes, respectively.

16 February 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
RBReimund Bayerlein
Reimund Bayerlein
BSBenjamin A Spencer
Benjamin A Spencer
ELEdwin K Leung
Edwin K Leung
NONegar Omidvari
Negar Omidvari
YAYasser G Abdelhafez
Yasser G Abdelhafez
RBRamsey D Badawi
Ramsey D Badawi
Objective. This study presents and evaluates a robust Monte Carlo-based scatter correction (SC) method for long axial field of view (FOV) and total-body positron emission tomography (PET) using the uEXPLORER total-body PET/CT scanner. Approach. Our algorithm utilizes the Monte Carlo (MC) tool SimSET to compute SC factors in between individual image reconstruction iterations within our in-house list-mode and time-of-flight-based image reconstruction framework. We also introduced a unique scatter scaling technique at the detector block-level for optimal estimation of the scatter contribution in each line of response. First image evaluations were derived from phantom data spanning the entire axial FOV along with image data from a human subject with a large body mass index. Data was evaluated based on qualitative inspections, and contrast recovery, background variability, residual scatter removal from cold regions, biases and axial uniformity were quantified and compared to non-scatter-corrected images. Main results. All reconstructed images demonstrated qualitative and quantitative improvements compared to non-scatter-corrected images: contrast recovery coefficients improved by up to 17.2% and background variability was reduced by up to 34.3%, and the residual lung error was between 1.26% and 2.08%. Low biases throughout the axial FOV indicate high quantitative accuracy and axial uniformity of the corrections. Up to 99% of residual activity in cold areas in the human subject was removed, and the reliability of the method was demonstrated in challenging body regions like in the proximity of a highly attenuating knee prosthesis. Significance. The MC SC method employed was demonstrated to be accurate and robust in TB-PET. The results of this study can serve as a benchmark for optimizing the quantitative performance of future SC techniques.