Mihaela Carmen CHEREGI

Dr. Mihaela Carmen CHEREGI

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2022 in Processes
Verified
Journal Article
Open access
PDF file
Iulia Gabriela DavidIulia Gabriela David
Iulia Gabriela David
MBMihaela Buleandra
Mihaela Buleandra
Dana Elena PopaDana Elena Popa
Dana Elena Popa
MCMihaela Carmen CHEREGI
Mihaela Carmen CHEREGI
VDVasile David
Vasile David
GTGeorgiana Oana Tartareanu
Georgiana Oana Tartareanu
The even growing production of both well-known and new derivatives with pharmaceutical action involves the need for developing facile and reliable methods for the analysis of these compounds. Among the widely used instrumental techniques, the electrochemical ones are probably the simplest and the most rapid, also having good performance characteristics. However, the key tool in electroanalysis is the working electrode. Due to the inherent electrochemical and economic advantages of the pencil graphite electrode (PGE), the interest in its applicability in the analysis of different analytes has continuously increased in recent years. Thus, this paper aims to review the scientific reports published in the last 10 years on the use of the disposable eco- and user-friendly PGEs in the electroanalysis of compounds of pharmaceutical importance in different matrices. The PGE characteristics and designs (bare or modified with various types of materials), along with their applications and performance parameters (e.g., linear range, limit of detection, and reproducibility), will be discussed, and their advantages and limitations will be critically emphasized.

1 July 2001 in Critical Reviews in Analytical Chemistry
Verified
Journal Article
Closed access
ADAndrei Florin Danet
Andrei Florin Danet
MCMihaela Carmen CHEREGI
Mihaela Carmen CHEREGI
JCJose Martinez Calatayud
Jose Martinez Calatayud
JMJose Vicente Garcia Mateo
Jose Vicente Garcia Mateo
HEHassan Y. Aboul Enein
Hassan Y. Aboul Enein
A comprehensive, critical, and an updated review of the applications of flow-injection analysis (FIA) techniques for the analysis of inorganic cations and anions in several types of water samples except marine waters is presented. The preconcentration of metals in water samples and automaton of FIA systems for monitoring water quality are also discussed. The review is documented with 280 references.

22 August 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
Iulia Gabriela DavidIulia Gabriela David
Iulia Gabriela David
Dana Elena PopaDana Elena Popa
Dana Elena Popa
MBMihaela Buleandra
Mihaela Buleandra
MCMihaela Carmen CHEREGI
Mihaela Carmen CHEREGI
Rosmarinic acid (RA) is an important bioactive phenolic acid with significant biochemical activities, including the antioxidant one. It is widely found in plants of the families Lamiaceae and Boraginaceae and has many uses in the food, pharmaceutical and cosmetics industries. RA is an electroactive species owing to the presence of the two catechol groups in its structure. Due to their inherent characteristics, such as sensitivity, selectivity, ease of operation and not too high costs, electrochemical methods of analysis are interesting tools for the assessment of redox-active compounds. Moreover, there is a good correlation between the redox potential of the analyte and its capability to donate electrons and, consequently, its antioxidant activity. Therefore, this paper presents a detailed overview of the electrochemical (bio)sensors and methods, in both stationary and dynamic systems, applied for RA investigation under different aspects. These comprise its antioxidant activity, its interaction with biological important molecules and the quantification of RA or total polyphenolic content in different samples.

27 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Iulia Gabriela DavidIulia Gabriela David
Iulia Gabriela David
MBMihaela Buleandra
Mihaela Buleandra
Dana Elena PopaDana Elena Popa
Dana Elena Popa
MCMihaela Carmen CHEREGI
Mihaela Carmen CHEREGI
EIEmilia-Elena Iorgulescu
Emilia-Elena Iorgulescu
Amphenicols are broad-spectrum antibiotics. Despite their benefits, they also present toxic effects and therefore their presence in animal-derived food was regulated. Various analytical methods have been reported for their trace analysis in food and environmental samples, as well as in the quality control of pharmaceuticals. Among these methods, the electrochemical ones are simpler, more rapid and cost-effective. The working electrode is the core of any electroanalytical method because the selectivity and sensitivity of the determination depend on its surface activity. Therefore, this review offers a comprehensive overview of the electrochemical sensors and methods along with their performance characteristics for chloramphenicol, thiamphenicol and florfenicol detection, with a focus on those reported in the last five years. Electrode modification procedures and analytical applications of the recently described devices for amphenicol electroanalysis in various matrices (pharmaceuticals, environmental, foods), together with the sample preparation methods were discussed. Therefore, the information and the concepts contained in this review can be a starting point for future new findings in the field of amphenicol electrochemical detection.

25 October 2023 in Antioxidants
Verified
Journal Article
Open access
PDF file
Iulia Gabriela DavidIulia Gabriela David
Iulia Gabriela David
EIEmilia-Elena Iorgulescu
Emilia-Elena Iorgulescu
Dana Elena PopaDana Elena Popa
Dana Elena Popa
MBMihaela Buleandra
Mihaela Buleandra
MCMihaela Carmen CHEREGI
Mihaela Carmen CHEREGI
HNHassan Noor
Hassan Noor
Curcumin (CU) is a polyphenolic compound extracted from turmeric, a well-known dietary spice. Since it has been shown that CU exerts beneficial effects on human health, interest has increased in its use but also in its analysis in different matrices. CU has an antioxidant character and is electroactive due to the presence of phenolic groups in its molecule. This paper reviews the data reported in the literature regarding the use of electrochemical techniques for the assessment of CU antioxidant activity and the investigation of the voltammetric behavior at different electrodes of free or loaded CU on various carriers. The performance characteristics and the analytical applications of the electrochemical methods developed for CU analysis are compared and critically discussed. Examples of voltammetric investigations of CU interaction with different metallic ions or of CU or CU complexes with DNA as well as the CU applications as electrode modifiers for the enhanced detection of various chemical species are also shown.

17 January 2025 in Molecules
Verified
Journal Article
Open access
PDF file
MBMihaela Buleandra
Mihaela Buleandra
LVLavinia Georgiana Voica
Lavinia Georgiana Voica
Dana Elena PopaDana Elena Popa
Dana Elena Popa
Irinel Adriana BadeaIrinel Adriana Badea
Irinel Adriana Badea
EIEmilia-Elena Iorgulescu
Emilia-Elena Iorgulescu
MCMihaela Carmen CHEREGI
Mihaela Carmen CHEREGI
This paper summarizes the main findings of a study which aimed to examine the electrochemical oxidation of homovanillic acid (HVA), the final metabolite of dopamine. A pencil graphite electrode (PGE) was used as working electrode and the measurements were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The type and the composition of the graphite leads used as PGE, the pH of the supporting electrolyte, as well as the scan rates were optimized by CV. The analyte was irreversibly oxidized in Britton–Robinson buffer (BRB) solutions. The interpretation of the voltammetric signals and the correlation of the acquired information were the key to addressing the electrode process undergone by HVA at the PGE. The outcomes of the pH and scan rate studies led to the conclusion that two electrons and two protons were involved in the diffusion-controlled process. Using the PGE, a linear relationship between peak current and HVA concentration was obtained between 1.0 × 10−6 M and 5.0 × 10−5 M by DPV in BRB with pH 2.0. The detection limit of 3.84 × 10−7 M was calculated. The accuracy, the precision, and the selectivity of the quantitative method have successfully undergone evaluation. The practical application of the developed voltammetric method was checked by determining the HVA concentration in spiked plasma samples, yielding good recovery values.