In deep geological repositories, compacted bentonites have been proposed for use as barrier materials for isolating nuclear waste. The prevailing thermo-hydro-mechanical boundary conditions in the repositories may affect the swelling capacity and permeability of the compacted bentonites. In this study, the effect of preliminary desiccation on the subsequent hydro-mechanical behaviour (swelling pressure and hydraulic conductivity) of compacted Calcigel bentonite was investigated experimentally at 22°C and 80°C. In the first stage of the test, the compacted specimens were subjected to suction-controlled desiccation at 22°C and 80°C using the vapour-equilibrium technique. After the water content reached equilibrium at a given suction, the axial, radial and volumetric shrinkage strains were measured. Afterwards, constant-volume swelling-pressure tests were performed on the desiccated specimens (second test stage) by saturating the dried specimens with deionized water at 22°C and 80°C. At the end of the swelling-pressure test, the hydraulic conductivities of four saturated specimens were measured at each temperature. The volumetric shrinkage strain of the compacted bentonite during desiccation is controlled by suction instead of temperature. In addition, the preliminary desiccation increases both the swelling pressure and hydraulic conductivity of compacted bentonite, particularly if compacted bentonite undergoes extreme desiccation at an applied suction of >700 MPa.
Compacted bentonite–sand mixture is proposed widely as backfill in geological repositories for disposal of radioactive waste in many countries because this material has significant swelling capacity and low water permeability. Development of the swelling pressure of backfills upon hydration is related closely to the stability of the host rock in the geological repository. No systematic experimental studies have been carried out to explore the effect of a water phase on the swelling pressure and water retention of bentonite–sand mixtures with insignificant osmotic suction. The objective of the current study was to examine experimentally the influence of a water phase involving liquid water and water vapor on swelling pressure and water retention of a bentonite–sand mixture with insignificant osmotic suction. Swelling-pressure tests with suction control and water-retention measurements under constant-volume conditions were performed on the compacted bentonite–sand mixture with a dry density of 1.80 g/cm3. Osmotic and vapor equilibrium techniques were used to make identical specimens adsorb liquid water and water vapor, respectively. The experimental results showed that the water phase had almost no effect on the swelling-pressure patterns of the unsaturated bentonite–sand mixture upon hydration over a suction range from 27 to 3 MPa. The swelling pressure increased significantly with decreasing suction from 27 to 3 MPa, regardless of the mixture adsorbing either the liquid water or water vapor. Nevertheless, the water phase had a considerable impact on both the swelling pressure and water retention of the unsaturated bentonite–sand mixture upon hydration over the same suction range. For a given value of suction in the range above, the swelling pressure and the water content of the bentonite–sand upon adsorption of liquid water were greater than those upon adsorption of water vapor. The influence of the water phase on the swelling pressure and the water retention of the bentonite–sand mixture with insignificant osmotic suction is related mainly to the hydration or swelling mechanism of Ca-rich bentonite.