Low-cost air quality sensors (LCS) are increasingly used to complement traditional air quality monitoring yet concerns about their accuracy and fitness-for-purpose persist. This scoping review investigates topics, methods, and technologies in the application of LCS networks in recent years that are gaining momentum, focusing on LCS networks (LCSN) operation, drone-based and mobile monitoring, data fusion/assimilation, and community engagement. We identify several key challenges remaining. A major limitation is the absence of unified performance metrics and cross-validation methods to compare different LCSN calibration and imputation techniques and meta-analyses. LCSN still face challenges in effectively sharing and interpreting data due to a lack of common protocols and standardized definitions, which can hinder collaboration and data integration across different systems. In mobile monitoring, LCS siting, orientation, and platform speed are challenges to data consistency of different LCS types and limit the transferability of static calibration models to mobile settings. For drone-based monitoring, rotor downwash, LCS placement, flight pattern, and environmental variability complicate accurate measurements. In integrating LCS data with air quality models or data assimilation, realistic uncertainty quantification, ideally at the individual measurement level, remains a major obstacle. Finally, citizen science initiatives often encounter motivational, technological, economic, societal, and regulatory barriers that hinder their scalability and long-term impact.
27 September 2021 in International Journal of Infectious Diseases
The second wave of COVID-19 due to the delta variant (B.1.617.2) led to a rapid rise in total coronavirus and COVID-associated mucormycosis cases reported from India. Hence, our study explored the possible causes of a rapid upsurge in COVID-associated mucormycosis, which has accounted for over 70% of global cases. Factors associated with the increase in mucormycosis cases in COVID-19 patients include diabetes mellitus, steroid overdose, high iron levels, and immunosuppression, combined with other possible factors, such as unhygienic conditions, prolonged hospitalization, use of ventilators, and leaky humidifiers in oxygen cylinders. These create an ideal environment for contracting mucormycosis. However, these cases could be reduced by disseminating simple preventive measures and creating awareness among the medical society and general public of this rare and deadly contagion of COVID-associated mucormycosis. The identification of early symptoms will also help to restrict the spread of lethal fungal diseases. Furthermore, a collaborative team of surgeons, ophthalmologists, physicians, and otolaryngologists would be required in the hospital wards to accelerate surgeries on severely impacted patients.
The first case of the coronavirus disease 2019 (COVID-19), the novel contagious disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), was reported in Wuhan, China in December 2019
Black carbon (BC) is emitted into the atmosphere during combustion processes, often in conjunction with emissions such as nitrogen oxides (NOx) and ozone (O3 ), which are also by-products of combustion. In highly polluted regions, combustion processes are one of the main sources of aerosols and particulate matter (PM) concentrations, which affect the radiative budget. Despite the high relevance of this air pollution metric, BC monitoring is quite expensive in terms of instrumentation and of maintenance and servicing. With the aim to provide tools to estimate BC while minimising instrumentation costs, we use machine learning approaches to estimate BC from air pollution and meteorological parameters (NOx, O3, PM2.5, relative humidity (RH), and solar radiation (SR)) from currently available networks. We assess the effectiveness of various machine learning models, such as random forest (RF), support vector regression (SVR), and multilayer perceptron (MLP) artificial neural network, for predicting black carbon (BC) mass concentrations in areas with high BC levels such as Northern Indian cities (Delhi and Agra), across different seasons. The results demonstrate comparable effectiveness among the models, with the multilayer perceptron (MLP) showing the most promising results. In addition, the comparability between estimated and monitored BC concentrations was high. In Delhi, the MLP shows high correlations between measured and modelled concentrations during winter (R 2: 0.85) and post-monsoon (R2: 0.83) seasons, and notable metrics in the pre-monsoon (R2: 0.72). The results from Agra are consistent with those from Delhi, highlighting the consistency of the neural network's performance. These results highlight the usefulness of machine learning, particularly MLP, as a valuable tool for predicting BC concentrations. This approach provides critical new opportunities for urban air quality management and mitigation strategies and may be especially valuable for megacities in medium- and low-income regions.
Understanding airborne particle mass deposition in the lungs is crucial for assessing health effects, particularly in regions with severe air pollution. While several studies have modelled lung deposition, there is limited information on lung tissue deposition that incorporates factors like hygroscopicity and density in polluted environments or source-specific exposures. This study examines the impact of atmospheric aerosol properties, including particle number size distribution, effective density, and hygroscopic growth, on lung tissue deposition using data from a measurement campaign in Delhi, India. Using the Hygroscopic Particle Lung Deposition (HPLD) model, the number (TDn) and mass (TDm) of tissue-deposited particles were calculated for various episodes: biomass burning (BB), chloride (Cl), hydrocarbon-like organic aerosol (HOA), and relatively clean (RC) periods. Chloride episodes, linked to industrial and waste burning activities, showed the highest tissue deposition mass (28 pg cm-2h-1), followed by BB (22 pg cm-2h-1), HOA (17 pg cm-2h-1), and RC (14 pg cm-2h-1) on total inner lung surface area. In addition, incorporating hygroscopicity and density increased deposition estimates by 1.8-2.8 times. This study underscores the importance of quantifying tissue deposition doses for improving exposure assessments, particularly in highly polluted regions where elevated particulate levels exacerbate lung inflammation, respiratory issues, and cancer risk.