Tomiharu Yamaguchi

Dr. Tomiharu Yamaguchi

Tokyo Denki University
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
KTKeiji Tsukada
Keiji Tsukada
MKMasatoshi Kariya
Masatoshi Kariya
TYTomiharu Yamaguchi
Tomiharu Yamaguchi
Toshihiko KiwaToshihiko Kiwa
Toshihiko Kiwa
HYHironobu Yamada
Hironobu Yamada
SKShinsuke Kunitsugu
Shinsuke Kunitsugu
We developed a dual-gate field-effect transistor (FET) hydrogen gas sensor for application to hydrogen vehicles. The dual-gate FET hydrogen sensor was integrated with a Pt-gate FET to detect hydrogen and a Ti-gate FET as the reference sensor in the same Si chip. The Ti-FET had the same structure as the Pt-FET except for the gate metal. The Pt-FET showed a good response to hydrogen gas above 10 ppm in air, while the Ti-FET did not show any response to hydrogen gas. The differential output voltage between the Pt-FET and the Ti-FET was stable in the temperature range from room temperature to 80 °C because of the same temperature dependence of the current–voltage (I–V) characteristics. In addition, the temperature of the integrated hydrogen sensor was controlled by an integrated system consisting of a heater and a thermometer at any given temperature under severe weather conditions.

30 October 2019 in Electronics and Communications in Japan
Verified
Journal Article
Closed access
PDF file
NYNobuo Yamamoto
Nobuo Yamamoto
TYTomiharu Yamaguchi
Tomiharu Yamaguchi
KHKazuhiro Hara
Kazuhiro Hara

23 July 2007 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KTKeiji Tsukada
Keiji Tsukada
TYTomiharu Yamaguchi
Tomiharu Yamaguchi
Toshihiko KiwaToshihiko Kiwa
Toshihiko Kiwa
A proton pumping field-effect transistor (FET), consisting of a triple layer gate structure of a Pd/proton conducting polymer/Pt, has been developed. The hydrogen sensitivity was controlled by the bias change between Pt and Pd. Furthermore, two kinds of methods for the readout of DC and AC modulation can be achieved. According to the decrement of the bias frequency, the modulated output was increased. This characteristic realizes a gas sensor with a self-check function.

9 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TYTomiharu Yamaguchi
Tomiharu Yamaguchi
AUAkinori Ueno
Akinori Ueno
In this study, we propose a new short-time impedance spectroscopy method with the following three features: (1) A frequency spectrum of complex impedance for the measured object can be obtained even when the measuring electrodes are capacitively coupled with the object and the precise capacitance of the coupling is unknown; (2) the spectrum can be obtained from only one cycle of the non-sinusoidal oscillation waveform without sweeping the oscillation frequency; and (3) a front-end measuring circuit can be built, simply and cheaply, without the need for a digital-to-analog (D-A) converter to synthesize elaborate waveforms comprising multiple frequencies. We built the measurement circuit using the proposed method and then measured the complex impedance spectra of 18 resistive elements connected in series with one of three respective capacitive couplings. With this method, each element’s resistance and each coupling’s capacitance were estimated independently and compared with their nominal values. When the coupling capacitance was set to 10 nF or 1.0 nF, estimated errors for the resistive elements in the range of 2.0–10.0 kΩ were less than 5%.

10 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ATAkihiko Tsukahara
Akihiko Tsukahara
TYTomiharu Yamaguchi
Tomiharu Yamaguchi
YTYuho Tanaka
Yuho Tanaka
AUAkinori Ueno
Akinori Ueno
In principle, the recently proposed capacitive-coupling impedance spectroscopy (CIS) has the capability to acquire frequency spectra of complex electrical impedance sequentially on a millisecond timescale. Even when the measured object with time-varying unknown resistance Rx is capacitively coupled with the measurement electrodes with time-varying unknown capacitance Cx, CIS can be measured. As a proof of concept, this study aimed to develop a prototype that implemented the novel algorithm of CIS and circuit parameter estimation to verify whether the frequency spectra and circuit parameters could be obtained in milliseconds and whether time-varying impedance could be measured. This study proposes a dedicated processor that was implemented as field-programmable gate arrays to perform CIS, estimate Rx and Cx, and their digital-to-analog conversions at a certain time, and to repeat them continually. The proposed processor executed the entire sequence in the order of milliseconds. Combined with a front-end nonsinusoidal oscillator and interfacing circuits, the processor estimated the fixed Rx and fixed Cx with reasonable accuracy. Additionally, the combined system with the processor succeeded in detecting a quick optical response in the resistance of the cadmium sulfide (CdS) photocell connected in series with a capacitor, and in reading out their resistance and capacitance independently as voltages in real-time.

20 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TYTomiharu Yamaguchi
Tomiharu Yamaguchi
EOEmiyu Ogawa
Emiyu Ogawa
AUAkinori Ueno
Akinori Ueno
Herein, we propose an impedance spectroscopy method using a mode-switching nonsinusoidal oscillator and apply this method for measuring the impedance of biological tissues and continuous impedance measurement. To obtain impedance spectra over a wide frequency range, we fabricated a novel nonsinusoidal oscillator incorporating binary counters and analog switches. This oscillator could periodically switch oscillation frequency through the mode switching of the feedback resistor. From the oscillation waveform at each oscillation frequency of this circuit (oscillator), we determined the impedance spectrum of a measured object using the discrete-time Fourier transform. Subsequently, we obtained the broad impedance spectrum of the measured object by merging odd-order harmonic spectral components up to the 19th order for each oscillation frequency. From the measured spectrum, the resistive and capacitive components of the circuit simulating bioimpedance were estimated with high accuracy. Moreover, the proposed method was used to measure the impedance of porcine myocardium; changes in the impedance spectrum of the myocardial tissue due to coagulation could be measured. Furthermore, rapid variations in the resistance value of a CdS photocell could be continuously measured using the proposed method.