Background and Objective: Guided bone regeneration allows new bone formation in anatomical sites showing defects preventing implant rehabilitation. Material and Methods: The present case series reported the outcomes of five patients treated with customized titanium meshes manufactured with a digital workflow for achieving bone regeneration at future implant sites. A significant gain in both width and thickness was achieved for all patients. Results: From a radiographic point of view (CBTC), satisfactory results were reached both in horizontal and vertical defects. An average horizontal gain of 3.6 ± 0.8 mm and a vertical gain of 5.2 ± 1.1 mm. Conclusions: The findings from this study suggest that customized titanium meshes represent a valid method to pursue guided bone regeneration in horizontal, vertical or combined defects. Particular attention must be paid by the surgeon in the packaging of the flap according to a correct method called the “poncho” technique in order to reduce the most frequent complication that is the exposure of the mesh even if a partial exposure of one mesh does not compromise the final outcome of both the reconstruction and the healing of the implants.
We performed this clinical study in order to evaluate the reliability of the Guided Bone Regeneration (GBR) surgical technique through the use of customized CAD CAM titanium meshes (Yxoss CBR® Reoss) in order to show an alternative method of bone augmentation. Materials and methods: Nine patients presenting 10 bone defects were referred to solve oral dysfunction due to edentulous atrophic ridges. Guided bone regeneration was performed with titanium meshes combined with autogenous bone grafting and heterologous bovine bone mineral grafting, and exclusively a “poncho technique” soft tissue approach for all the cases. After a mean 9 months of graft healing (range 6–12 months), titanium meshes were removed, and implant surgery was subsequently performed. The results we obtained were positive in terms of volumetric increases in height, length and thickness of the atrophic ridges without biological complications detectable before implant surgery. Results: Out of nine, one site met titanium mesh exposure: however, in all 10 sites a three-dimensional volumetric bone implementation was obtained. The statistical results were estimated by uploading and superimposing cbct scans before and after CBR surgery for each patient, so it was possible evaluate the maximum linear vertical and horizontal bone gain through dedicated Cad Cam software (Exocad GmbH®). The average horizontal gain was 6.37 ± 2.17 mm (range 2.78–9.12 mm) and vertical gain was 5.95 ± 2.06 mm (range 2.68–9.02 mm). A total of 18 implants were placed into the grafted sites with a 100% survival rate (clearly they are relative percentages to be compared to the short time elapsed). Conclusions: The results we obtained in this study suggest that this CBR procedure (Yxoss® by Reoss) is reliable and safe for bone regeneration to allow implant-prosthetic restoration in horizontal, vertical and combined bone defects. The soft tissue management is diriment: all the cases were managed with a “poncho” flap approach to decrease exposure complication.
The aim of this article is to describe a novel approach combining muco-gingival, regenerative and prosthetics concepts for immediate implant insertion that overcomes the limits traditionally considered as contraindications for Type 1 flapless implant positioning, simultaneously obtaining soft- and hard-tissue augmentation. After pre-surgical CBCT evaluation, the surgical technique consisted in the execution of a lateral-approach coronally advanced envelope flap, with oblique submarginal interproximal incisions directed towards the flap’s center of rotation (the tooth to be extracted); after buccal-flap elevation, the atraumatic extraction of the tooth was performed. Following guided implant insertion, a mixture of biomaterial and autologous bone was placed, stabilized by a pericardium membrane and a connective-tissue graft sutured in the inner aspect of the buccal flap. The peri-implant soft tissues were conditioned with a provisional crown until the shape and position for the mucosal scallop to resemble the gingival margin of the adjacent corresponding tooth were obtained; then, the definitive screw-retained restoration was placed. Within the limitations of this case report, the proposed immediate implant placement approach combining CTG application and buccal bone regeneration showed the possibility of obtaining 1-year-follow-up implant success, stable bone level, good esthetic results and high patient satisfaction.
Gingival recession is a mucogingival defect defined as the apical shifting of the gingival margin in relation to the CEJ. The use of connective tissue autografts allows for the obtention of very satisfactory results but is associated with undoubted disadvantages. The aim of the present work is to carry out a systematic review of the literature using a meta-analysis to investigate the clinical efficacy of xenogeneic collagen matrix (XCM) in the treatment of gingival recessions. This revision was carried out strictly following the guidelines published in the Cochrane Handbook. Thus, a meta-analysis was performed to calculate relative risks and standardized mean differences for each of the variables considered. The results of the meta-analysis show that CAF + CTG was statistically better than CAF + XCM in almost all the variables analyzed: complete root coverage (RR 0.46), mean root coverage (SMD −0.89), recession reduction (SMD −0.98), clinical attachment level (SMD −0.63) and gingival thickness (SMD −1.68). Meanwhile, CAF + XCM was slightly better than CAF alone in regard to: mean root coverage (SMD 0.51), recession reduction (SMD 0.47) and gingival thickness (SMD 0.56). It is possible to conclude that CAF + CTG still remains the gold standard in radicular coverage.
Background and Objectives: Implant placement with static navigation enables the reaching of a correct position of implants from an anatomical and prosthetic point of view. Different approaches of static navigation are described in the scientific literature, and the pilot-guided approach is one of the least investigated. The aim of the present study is the evaluation of the accuracy of implant insertion using a pilot drill template. Materials and Methods: Fifteen partially edentulous patients, requiring an implant rehabilitation of at least one implant, were enrolled. Pre- and post-operative low-dose CTs were acquired to measure the differences between final positions of implants and virtually planned ones. Three linear discrepancies (coronal, apical, and depth), two angular ones (bucco-lingual and mesio-distal), and the imprecision area were evaluated. Correlations between accuracy and rehabilitated jaws, sectors, and implant length and diameters were also analyzed. Results: Forty implants were inserted in fifteen patients using pilot drill templates. Mean coronal deviation was 1.08 mm, mean apical deviation was 1.77 mm, mean depth deviation was −0.48 mm, mean bucco-lingual angular deviation was 4.75°, and mean mesio-distal one was 5.22°. The accuracy was statistically influenced only by the rehabilitated jaw for coronal discrepancy and sectors and implant diameter for bucco-lingual angular deviations. Conclusions: The pilot drill template could represent a predictable solution to obtain a correct implant placement. Nonetheless, a safety margin of at least 2 mm should be respected during implant planning to prevent damages to anatomical structures. Therefore, the tool is helpful in order to prosthetically drive the implants; still, great attention must be paid in fully relying on this procedure when approaching dangerous structures such as nerves and vessels.
Background: In this multicenter case series analysis, the authors present successful instances of 20 single-screw-retained and implant-supported prosthetic rehabilitation samples. Methods: A high-density heterologous dermal matrix (Derma® Osteobiol by Tecnoss, Torino, Italy) was employed with a specific technique named the matrix tissue graft (MTG) in all these cases characterized by an inadequate initial supra-crestal tissue height (thin if 1 mm or medium if 2 mm) to enhance the peri-implant soft tissues both vertically and horizontally. Results: The implants were deemed successful in all cases, yielding a success proportion of 100% (one-sided 97.5% confidence interval = 83.2–100%). The buccal and lingual gains were, respectively, 2.2 ± 0.38 mm (range 1.7–3.22 mm) and 0.83 ± 0.33 mm (range 0.1–1.5 mm). These measurements were calculated as the maximum distance between two superimposed .stl file models (derived from two different IOS devices) scanned before implant placement and 1 year after dermal matrix healing. Conclusions: An outstanding vertical and horizontal gain was obtained using this heterologous derma matrix placed above the bone crest and surrounding the dental implants.